Broken window: safe temporary fix and cleanup¶
Emergency numbers differ by country. This page uses 911, the number for the United States and Canada. Many other countries use 112, 999, or another number. Find the number for your country.
A shattered residential or commercial window breaches the weather-tight and security envelope of a building, exposing occupants to falling dagger shards, wind-driven rain, rapid thermal loss, and opportunistic intrusion. Stabilizing the opening safely requires clearing hanging glass from the top down in full personal protective equipment, isolating microscopic silica slivers from living areas, and installing a non-destructive tension-clamp plywood barrier or dual-layer 6-mil polyethylene weather seal.
Do this now¶
- Evacuate children and pets from the room immediately and put on hard-soled shoes. High-velocity glass fragments scatter up to 6 meters (20 feet) across flooring and furniture upon impact. Close the interior door or place a physical barrier across the hallway so no one walks into the hazard zone barefoot or in socks.
- Determine whether the broken window is an active crime scene. If the glass was shattered by an attempted burglary, home invasion, or projectile vandalism, do not touch the window frame, sill, or floor shards. Retreat to a safe room or exit the building and call your local emergency number (911 in the United States and Canada, 112 across the European Union, 999 in the United Kingdom) or consult our emergency numbers directory so police can check the structure and preserve latent fingerprints.
- Check all occupants for severe lacerations or embedded glass. If anyone is bleeding heavily, apply firm direct pressure with a clean cloth. If a glass shard is deeply embedded in flesh, never pull it out; stabilize the protruding shard in place with bulky rolled gauze or towels on either side and seek emergency medical care immediately.
- Put on heavy leather work gloves, ANSI Z87.1 or EN 166 impact-rated safety goggles, long sleeves, and thick-soled boots before approaching the window. Never handle broken architectural glass with bare hands, cotton gardening gloves, or thin disposable nitrile gloves, which slice open on contact.
- Photograph the damage from multiple angles before sweeping or boarding up. Capture wide and close-up images of the window sash, exterior point of impact, damaged blinds or furniture, and the radius of shattered glass on the floor to substantiate your homeowner, renter, or commercial property insurance claim.
- Extract dangerous hanging shards from the top of the frame downward, then seal the opening. Use locking pliers to dislodge overhead hanging glass into a rigid cardboard box before installing a 12-millimeter (½-inch) exterior plywood compression board-up or a 6-mil polyethylene weather barrier.
Danger
Never stand directly underneath a broken window on the exterior of a building, and never reach your bare hands or forearms into a window frame while shards remain wedged in the upper sash. Standard annealed window glass fractures into heavy, razor-edged triangular daggers known as "guillotine shards." A minor vibration from closing a door or tapping a lower pane can cause an overhead shard to drop vertically, severing the radial or brachial artery, wrist tendons, and median nerve in a fraction of a second.
Broken window emergency triage and board-up workflow¶
Follow this operational decision tree to assess safety, clear the frame, and select the correct boarding method without damaging your window casing.
flowchart TD
A["Window Shatters or Structural Glass Breach"] --> B{"Caused by Crime or Intrusion?"}
B -->|Yes: Burglary or Vandalism| C["Evacuate Room, Do Not Touch Sill, Call 911 / 112 / 999"]
B -->|No: Storm, Impact, or Thermal Stress| D["Evacuate Kids and Pets, Put On Boots, Leather Gloves, Eye PPE"]
C --> E["Wait for Police Clearance and Incident Report Number"]
E --> D
D --> F{"Is Double-Pane IGU Cracked on One Side Only?"}
F -->|Yes: Intact Inner or Outer Pane| G["Apply Cross-Hatched Duct or Crash Film Tape Across Cracks"]
F -->|No: Full Through-and-Through Breach| H["Extract Hanging Shards From Top Sash Downward With Pliers"]
H --> I["Sweep Perimeter Inward, Adhesive-Roll Floor, Bare-Hose Vacuum"]
I --> J{"Ground Floor or High Wind / Rain?"}
J -->|Yes: Needs Security and Storm Resistance| K["Install 12mm / 1/2-Inch Plywood Tension-Clamp Sandwich"]
J -->|No: Upper Story Calm Weather Only| L["Install Dual-Layer 6-Mil Polyethylene With Exterior Flashing Tape"]
Architectural glass types, fracture mechanics, and hazard profiles¶
Before touching a damaged window, identify what type of glass you are dealing with. Modern residential and commercial windows use four distinct glazing configurations, each presenting unique physical hazards and temporary stabilization options.
| Glazing Type | Typical Locations in Buildings | Fracture Pattern and Physics | Primary Injury Hazard | Immediate Stabilization Protocol |
|---|---|---|---|---|
| Annealed (Float) Glass | Older single-pane windows, upper-wall non-hazardous sashes, picture frames | Breaks under low bending stress into long, acute-angled, dagger-like triangular shards | Extreme: Deep arterial and tendon lacerations; falling overhead guillotine shards | Apply cross-hatched heavy duct tape before extraction if partially cracked; pull top shards first with locking pliers |
| Fully Tempered Safety Glass | Sliding patio doors, entry sidelights, bathroom/shower windows, low floor-to-ceiling panes | Heat-treated surface compression of at least 69 megapascals (10,000 psi); shatters completely into thousands of 6-millimeter (¼-inch) granular cubes | Moderate: High-velocity granular spray; razor-sharp micro-slivers embedded in skin, eyes, and pet paws | If spiderwebbed but still standing in frame, lay a canvas drop cloth beneath and push outward into a box with a broom handle |
| Laminated Safety Glass (PVB or SGP Interlayer) | Hurricane impact windows, skylights, commercial storefronts, high-security ground-floor windows | Two glass plies bonded to a 0.76-to-2.28-millimeter (0.030-to-0.090-inch) polyvinyl butyral (PVB) or ionoplast interlayer; spiderwebs but stays in sheet form | Low to Moderate: Microscopic surface flaking and sharp perimeter edges if torn free from frame | Leave laminated sheet in the window frame as its own weather barrier; seal cracked surface on both sides with self-adhesive crash wrap film |
| Insulated Glass Unit (IGU / Double or Triple Pane) | Modern energy-efficient casement, double-hung, and fixed vinyl, fiberglass, or aluminum windows | Two or three panes separated by an aluminum or warm-edge desiccant spacer bar filled with argon or krypton gas | Variable: Depends on whether panes are annealed or tempered; loss of thermal seal causes internal condensation | If only one pane (exterior or interior) is broken and the second pane is intact, clear broken shards carefully and tape 6-mil poly over the damaged side without puncturing the intact pane |
Stabilizing a cracked but intact pane before it falls¶
If a window is cracked from an impact or thermal stress (such as cold water hitting sun-heated float glass) but the pieces have not yet fallen out of the sash:
- Put on leather gloves and safety glasses before touching the surface.
- Apply strips of heavy-duty cloth duct tape or clear automotive crash-wrap film in a crisscross X-grid and perimeter border directly over the cracked glass face, pressing gently so you do not push the pane through the frame.
- The adhesive backing binds the adjacent fractured glass plates together into a single Flexible web. If the pane subsequently gives way during wind gusts or when the glazier removes the stops, the shards remain stuck to the tape rather than raining down onto the floor.
Step-by-step protocol for removing hanging glass from the frame¶
When a window is knocked out, jagged shards remain locked inside the perimeter wood putty, vinyl glazing beads, or rubber gaskets. You must clear these protruding teeth before fitting plywood or plastic sheeting so they do not slice through the weather barrier or your hands.
1. Lay a containment drop zone directly beneath the window¶
Before touching the sash, spread a heavy canvas drop cloth, moving blanket, or flattened corrugated cardboard box on the floor directly beneath the interior window sill and outside on the ground below the exterior sill. This catches falling fragments and prevents shards from bouncing across carpet pile or outdoor grass and soil, where they are nearly impossible to see later.
2. Enforce the strict Top-to-Bottom extraction sequence¶
Always work from the top horizontal header of the sash down the vertical jambs to the bottom sill last:
- Why top-first is mandatory: If you begin pulling glass out of the bottom sill or lower corners first, the mechanical flexing of the sash frame will shake loose heavy shards hanging directly above your wrists and head.
- Stand to the side, never directly under the plane of the glass: Position your body inside the room slightly to the left or right of the window opening, keeping your torso, face, and feet clear of the vertical drop path.
- Grip with locking pliers or channel locks: Clamp the jaws of heavy pliers onto the base of an upper hanging shard near the frame track. Rock the pliers gently back and forth by 1 to 2 centimeters (0.5 inches) along the plane of the frame until the brittle neck fractures or slides free from the rubber glazing spline.
- Never strike glass outward with a hammer: Unless clearing a fully tempered granulated sheet into an empty, barricaded courtyard, avoid smashing panes with a hammer, which propels microscopic silica needles up to 6 meters (20 feet) and ruins the vinyl or aluminum glazing channels needed to install the replacement glass unit.
3. Clear the weep holes and sliding tracks¶
In vinyl and aluminum sliding or double-hung windows, tiny glass cubes fall inside the hollow bottom sill track and block the exterior drainage weep holes. Use a stiff narrow paintbrush or putty knife to flick fragments out of the track channels, then suction the sill track thoroughly with a shop vacuum hose attachment so water does not back up into your wall cavity during rainstorms.
Multi-stage indoor and outdoor glass cleanup¶
Standard household sweeping leaves behind thousands of nearly invisible glass splinters that cause deep puncture wounds weeks later. Follow Occupational Safety and Health Administration (OSHA) and professional restoration standards to decontaminate the room completely.
Stage 1: Rigid-container disposal of large shards¶
- Pick up all visible glass pieces larger than a coin using leather-gloved hands or kitchen tongs.
- Place them directly into a heavy corrugated cardboard box, a 19-liter (5-gallon) rigid plastic bucket, or a double-walled paper grocery bag lined with cardboard.
- Never drop broken glass into a thin plastic kitchen trash bag. Even a single shard slices through polyethylene trash bags like a scalpel, severing the calf muscles or Achilles tendon of the person carrying the bag to the curb or injuring municipal sanitation workers.
Stage 2: The flashlight oblique-angle sweep¶
- Turn off the overhead room lights or close the blinds and lay a bright LED flashlight flat on the floor so its beam shines horizontally across the floor surface.
- Every tiny glass shard and splinter will cast a long shadow and glint brightly against hardwood, tile, or carpet.
- Using a stiff-bristled broom (not a soft feather duster) and a metal dustpan, sweep slowly from the outermost 6-meter (20-foot) perimeter inward toward the window. Short, controlled strokes keep fine glass dust from launching into the air.
Stage 3: Soft furnishings, bedding, and HVAC register decontamination¶
- Bedding, curtains, and clothing: If the broken window sits near a bed, sofa, or dining table, assume microscopic glass slivers are embedded in the fabric. Fold sheets, blankets, and curtains carefully inward toward their center (so shards stay trapped inside the fold), carry them outdoors, and shake them out over a paved surface before washing them separately. Discard any open food, drinks, ice buckets, or uncovered pet water bowls anywhere in the room; ingested glass splinters cause gastrointestinal perforation.
- Floor HVAC supply vents: If your home has forced-air floor heating or cooling registers near the window, lift the metal grille and vacuum inside the boot duct immediately so shards do not rattle down into the furnace plenum or blow dust back into the room.
Stage 4: Bare-hose vacuuming and adhesive micro-sliver extraction¶
- Canister or wet-dry shop vacuum with bare nozzle only: Vacuum the entire floor, sofa cushions, and window tracks using only the open wand or crevice tool of a shop vacuum or canister vacuum.
- Never use an upright vacuum with a spinning beater bar / brush roll: A high-speed rotating brush roll turns glass cubes into projectiles, embeds micro-needles permanently into the nylon bristles of the vacuum brush (which then deposit glass across every other room you vacuum in the future), and slices the rubber drive belt.
- Adhesive final pass: Wrap 5-centimeter (2-inch) wide heavy duct tape sticky-side-out around a paint roller or your gloved hand, or use a fresh adhesive lint roller, and press it systematically across every square centimeter of carpet, grout lines, and hardwood seams. On smooth tile or wood floors, follow with a damp, thickly folded paper towel wiped in one direction and discarded immediately.
- Decontaminate your broom and shoe soles: Before leaving the room, step outside and brush the bristles of your broom and the rubber treads of your boots over cardboard, then rinse them with a garden hose so you do not track trapped slivers into kitchens or bedrooms.
Emergency window boarding methods and structural comparison¶
Choosing how to cover the breached opening depends on whether the window is at ground level (requiring physical intrusion resistance), whether high storm winds are forecast, and what material the window frame is made from (vinyl, aluminum, fiberglass, brick masonry, or wood).
| Boarding / Sealing Method | Physical Security Rating | Wind & Rain Resistance | Impact on Existing Window Frame | Required Tools and Materials |
|---|---|---|---|---|
| Method 1: Tension-Clamp Sandwich (FEMA / USFA Non-Destructive Standard) | Maximum (Cannot be pried or unscrewed from outside) | Hurricane-grade (Withstands severe positive and negative wind pressures) | Zero damage: Clamps by compression; zero screw holes in vinyl, aluminum, or wood trim | Exterior 12 mm (½ in) or 16 mm (⅝ in) CDX plywood, interior 38 x 89 mm (2x4 in) strongbacks, 10 mm (⅜ in) galvanized carriage bolts, washers, and nuts |
| Method 2: Recessed Barrel-Bolt / Compression Wedge Framing | High | High (Fits flush inside deep brick or concrete masonry reveals) | Minimal: Uses tension wedges or masonry anchors in mortar joints, sparing the window sash | 16 mm (⅝ in) exterior plywood cut 6 mm (¼ in) smaller than exterior brick mold reveal, heavy sliding barrel bolts or timber wedges |
| Method 3: Direct Exterior Face-Screwing (Wood Casing Only) | Moderate to High | High | Permanent screw holes: Punctures exterior wooden brick-mold or siding; never use on vinyl or aluminum frames | 12 mm (½ in) exterior plywood, 65 mm (2.5 in) coated deck screws or corrosion-resistant structural wood screws (never drywall screws) |
| Method 4: Dual-Layer 6-Mil Polyethylene Air-Gap Seal | Zero (Weather barrier only; easily cut with a knife) | Moderate (Holds against rain and moderate wind when splined with wood lath) | Minimal: Exterior flashing tape may leave adhesive residue or peel loose paint on interior trim | 6-mil (0.15 mm) polyethylene construction sheeting, exterior butyl/acrylic stucco or flashing tape, optional wood screen lath strips |
| Method 5: Self-Adhesive Collision / Crash Wrap Film | Low (Holds cracked laminated or tempered glass together) | Moderate to High (Waterproof adhesive skin across existing frame) | Zero structural holes: Strong acrylic adhesive clings directly to clean glass and vinyl frames | 3-mil to 4-mil punctured-resistant self-adhesive automotive collision wrap roll, utility knife, squeegee |
Warning
Never drive wood screws into a modern vinyl (uPVC), fiberglass, or thermally broken aluminum window sash to attach plywood. Puncturing a multi-chambered vinyl extrusion cracks the weld seams, destroys the internal drainage chambers, and voids the window manufacturer warranty, turning a simple 250 USD glass unit replacement into a 1,500 USD full-frame window tear-out. Always use the non-destructive tension-clamp sandwich method on vinyl and metal windows.
Step-by-step instructions: The non-destructive tension-clamp board-up¶
Recommended by the United States Fire Administration (USFA) and the Federal Emergency Management Agency (FEMA) for urban search-and-rescue and residential storm mitigation, the tension-clamp sandwich method locks an exterior sheet of plywood tightly against the building exterior using interior timber cross-bars and through-bolts, without drilling a single hole into your home or window frame.
Materials needed per window¶
- 1 exterior panel of 12-millimeter (½-inch) or 16-millimeter (⅝-inch) CDX exterior plywood (or Oriented Strand Board / OSB rated for exterior exposure). Avoid particleboard or MDF, which swell and disintegrate when wet.
- 2 interior strongback cleats made of 38 x 89 millimeter (nominal 2x4 inch) structural framing lumber.
- 4 galvanized steel carriage bolts, 10 millimeters (⅜ inch) in diameter. The bolt length must equal the depth of your window jamb wall thickness plus 10 centimeters (4 inches) (typically 20 to 30 centimeters or 8 to 12 inches long, or cut from 10-millimeter / ⅜-inch all-thread steel rod with double nuts locked on the exterior).
- 4 wide flat steel fender washers and 4 hex nuts (or wing nuts) sized for 10-millimeter (⅜-inch) bolts.
- Foam pipe insulation or folded towels to cushion the interior drywall or wood casing trim where the 2x4 cleats press against the wall.
Assembly and installation steps¶
- Measure the exterior window opening: Measure the width and height of the exterior window recess (brick mold or siding opening). Cut your exterior plywood panel so it overlaps the window opening by 10 centimeters (4 inches) on all four sides (if mounting flat against the exterior wall surface) or fits neatly inside the exterior brick reveal with a 6-millimeter (¼-inch) perimeter clearance.
- Cut the interior 2x4 strongbacks: Cut two pieces of 38 x 89 millimeter (2x4 inch) lumber so they are 30 centimeters (12 inches) wider than the interior window opening. These bars will span horizontally across the inside of the window frame, resting against the interior wall studs on the left and right sides of the casing.
- Drill the four through-bolt holes in the exterior plywood: Lay the plywood flat. Drill four 10-millimeter (⅜-inch) holes positioned inside the four corners of the open window space (approximately 15 centimeters / 6 inches inward from the inner edges of the window jamb so the bolts pass cleanly through the open window hole without touching the sash frame).
- Drill matching holes in the two interior 2x4 strongbacks: Align the upper 2x4 strongback with the top two holes of the plywood and drill two 10-millimeter (⅜-inch) holes through the wide face of the 2x4. Repeat for the lower 2x4 strongback matching the bottom two holes.
- Insert the carriage bolts from the outside facing in: Push the four carriage bolts through the exterior side of the plywood panel so the smooth, domed, slotless bolt heads face outdoors and the threaded shafts point into the house. (Because carriage bolt heads have no screwdriver slot or hex flats on the outside, a burglar outside cannot unbolt the panel; the square neck beneath the dome bites into the plywood to prevent spinning.)
- Optional weather gasket: Wrap foam weatherstripping tape around the inside perimeter face of the exterior plywood so it forms a watertight compression seal against the exterior wall or brick mold.
- Position the exterior panel and slide on the interior strongbacks: Have a helper hold the plywood against the outside of the window (or tie a safety rope around the bolts while hoisting it through the open window frame from the inside on upper floors). From inside the room, slip the top and bottom 2x4 strongback bars over the four protruding bolt threads, placing folded hand towels or foam pipe insulation between the ends of the 2x4s and your interior drywall or wood trim to prevent scuffing.
- Install fender washers and tighten the nuts: Slip a wide steel washer and hex nut onto each of the four bolt ends inside the room. Tighten all four nuts evenly with a socket wrench until the exterior plywood compresses snugly against the outside of the window frame.
Step-by-step instructions: Dual-layer 6-mil polyethylene weatherproofing¶
If a broken window occurs on an upper story where burglary is not a concern and you do not have immediate access to plywood and lumber, you can construct an airtight, rain-shedding thermal barrier using heavy plastic sheeting.
- Select the right plastic film: Use clear or black 6-mil (0.15-millimeter) polyethylene construction film (available at any hardware store in the painting or concrete aisle) or reinforced poly tarp material. Never use thin 0.7-mil painters drop cloths or kitchen cling wrap, which blow out during the first 25-kilometer-per-hour (15-mile-per-hour) wind gust.
- Clean and dry the perimeter frame: Wipe all moisture, dust, and dirt off the exterior window casing and interior trim using isopropyl alcohol or a dry cloth; tape will not stick to wet or dusty vinyl and paint.
- Install the exterior rain-shedding layer: Cut a sheet of 6-mil polyethylene 15 centimeters (6 inches) larger than the window frame on all sides. Apply heavy exterior-grade waterproof tape (such as butyl flashing tape, red stucco poly-tape, or heavy UV-resistant duct tape) along the top edge first, pulling the plastic drum-tight as you tape down the sides and bottom.
- Reinforce with wood lath battens if on a wood frame: If the exterior casing is painted wood and heavy rain or wind is occurring, wrap the edges of the 6-mil plastic around thin wooden paint-stirring sticks or screen-molding strips and tack them down so wind cannot peel the adhesive edge.
- Install the interior dead-air thermal layer: Cut a second sheet of 6-mil polyethylene and tape it tightly across the interior window trim inside the room. Trapping a 10-to-15-centimeter (4-to-6-inch) pocket of still dead air between the exterior and interior plastic layers acts like an insulated double-pane window, cutting conductive winter heat loss or summer heat gain by more than 60 percent compared to a single plastic sheet.
Glazing building codes and ordering permanent replacement glass¶
When calling a residential glazier or glass shop for a permanent repair, giving them accurate measurements and knowing mandatory safety-glazing building codes saves time and avoids failed building inspections.
Mandatory safety glazing locations (IRC Section R308 / BS 6262 / National Building Code of Canada)¶
Building codes across the United States (International Residential Code Section R308 and Consumer Product Safety Commission 16 CFR 1201), the United Kingdom (Approved Document K and BS 6262-4), Canada, and the European Union prohibit replacing broken glass with ordinary annealed float glass in high-risk human-impact zones. Tempered or laminated safety glass is legally required in all of the following locations:
- Doors and storm doors: All glass panes installed inside swinging, sliding, storm, or bi-fold doors.
- Adjacent to doors: Any window glazing located within a 60-centimeter (24-inch) arc of either vertical edge of a door where the bottom edge of the glass is less than 152 centimeters (60 inches) above the floor or walking surface.
- Large low-sill windows: Any individual fixed or operable pane that meets all four of the following criteria:
- Single pane surface area exceeds 0.84 square meters (9 square feet);
- Bottom exposed edge is less than 45 centimeters (18 inches) above the floor;
- Top exposed edge is more than 91 centimeters (36 inches) above the floor; and
- There is a walking surface within 91 centimeters (36 inches) horizontally of the glazing.
- Wet locations: All windows and walls facing or enclosing bathtubs, showers, hot tubs, saunas, and whirlpools where the bottom edge of the glass is less than 152 centimeters (60 inches) above the standing surface.
- Stairways, ramps, and landings: Any glazing located within 91 centimeters (36 inches) horizontally of a stairway, landing, or ramp and less than 152 centimeters (60 inches) above the nose of the stair tread. (In the United Kingdom under Approved Document K, any window glazing within 80 centimeters (31.5 inches) of floor level or within 30 centimeters (12 inches) of a door below 150 centimeters / 59 inches must meet Class B or Class C impact standards under BS EN 12600.)
Why double-pane Insulated Glass Units (IGUs) require two visits¶
If your broken window is a modern double-pane or triple-pane Insulated Glass Unit (two panes hermetically factory-sealed around a metal spacer bar with desiccant and argon gas), a glazier cannot simply cut a single piece of glass on the truck and putty it in:
- Visit 1 (Measurement and board-up): The glazier removes the interior vinyl or aluminum snap-in glazing beads, measures the exact width, height, overall unit thickness (for example, 19 millimeters or ¾ inch), glass tint, Low-E coating surface, and internal Colonial grille bars, and secures the opening.
- Factory fabrication (3 to 10 business days): Because tempered glass cannot be cut or drilled after it passes through a tempering furnace (cutting tempered glass causes it to explode instantly), the glass factory must custom-cut annealed glass to your exact millimeter dimensions, heat-treat it in the tempering oven, and seal the two panes together with argon gas.
- Visit 2 (IGU installation): The glazier pops out the old broken IGU cassette from your existing window sash, installs the new factory-sealed IGU onto neoprene setting blocks, and snaps the existing vinyl glazing beads back in place in under 30 minutes without disturbing your drywall or siding.
Insurance claims, deductibles, and tenant habitability rights¶
Homeowner and commercial property insurance vs. out-of-pocket cost¶
Before filing a formal homeowner insurance claim for a single broken residential window, compare the repair cost against your policy deductible:
- Typical glazier replacement cost: Replacing a single-pane annealed glass pane typically costs 120 to 300 USD (100 to 250 GBP), while ordering and installing a custom double-pane tempered IGU cassette typically costs 250 to 650 USD (200 to 500 GBP).
- Deductible math: Most homeowner insurance policies carry a standard deductible of 500 to 2,500 USD (or a separate 1 to 5 percent windstorm/named-storm deductible). If only one or two windows were broken and total glazier costs are below or barely above your deductible, paying a local glass shop out of pocket prevents a claim entry on your Complete Loss Underwriting Exchange (CLUE) report and avoids premium surcharges.
- Reasonable emergency mitigation coverage: If multiple windows were shattered by a severe storm, fallen tree, or burglary and you file a covered claim, standard property policies (ISO HO-3 Section I Additional Coverages: Reasonable Repairs) reimburse you for the out-of-pocket cost of emergency plywood, 2x4s, carriage bolts, plastic sheeting, and professional emergency board-up services required to protect the interior from secondary rain damage. Save every hardware store receipt.
Tenant rights and landlord emergency obligations¶
If you rent an apartment or house, an intact, lockable, weather-tight exterior window is a core legal requirement under the Implied Warranty of Habitability in the United States, the Landlord and Tenant Act 1985 (Section 11) and Homes (Fitness for Human Habitation) Act 2018 in the United Kingdom, and provincial Residential Tenancies Acts across Canada and Australia:
- 24-hour emergency security mandate: When an exterior window breaks through no fault of the tenant (such as storm damage, criminal break-in, thermal stress, or rotted sash frames), most municipal housing codes classify a ground-floor breach or freezing-weather window failure as an urgent habitability emergency requiring the landlord to perform an emergency board-up or temporary weather seal within 24 hours, followed by permanent glass replacement within a reasonable window (typically 7 to 14 days depending on custom IGU fabrication).
- Documenting notice in writing: Immediately send your landlord or property manager a time-stamped email and text message containing photos of the broken window, the police report number (if caused by vandalism or break-in), and a clear request for immediate emergency boarding and glazier scheduling.
Note
If a ground-floor window is shattered during a burglary or domestic threat and your landlord cannot arrive for several hours, board the window up yourself using the non-destructive tension-clamp sandwich method or hire an emergency glazier after notifying the landlord, and keep all itemized receipts and photos for reimbursement under your jurisdiction's statutory repair-and-deduct rules.
Frequently asked questions¶
How do I board up a broken vinyl or aluminum window without drilling screw holes into the frame?
Use the tension-clamp sandwich method. Cut a sheet of 12-millimeter (1/2-inch) exterior plywood to overlap the outside of the window opening by 10 centimeters (4 inches) on all sides, and cut two lengths of 38 x 89 millimeter (2x4 inch) lumber 30 centimeters (12 inches) wider than the interior window opening. Drill four 10-millimeter (3/8-inch) holes through the plywood and matching holes through the 2x4 cross-bars, push four carriage bolts through the plywood from the outside facing in, slip the 2x4 strongbacks over the bolt ends inside the house (with folded towels protecting your drywall), and tighten washers and nuts from the inside. Clamping pressure holds the plywood rock-solid with zero holes drilled into the window frame.
What should I do if only one pane of my double-pane window is broken and the other pane is completely intact?
If only the outer pane or only the inner pane of an Insulated Glass Unit (IGU) is broken while the second pane remains completely intact, your home is still sealed against rain and intruders. Put on leather gloves and safety goggles, gently remove any loose hanging shards from the broken side using locking pliers without poking the intact glass pane, vacuum the sill with a bare hose, and tape a sheet of clear 6-mil polyethylene plastic across the broken side to restore the insulating air pocket and contain any residual splinters until the glazier installs a new factory-sealed IGU.
Why should I never use an upright vacuum cleaner to pick up broken glass on carpet?
Upright vacuum cleaners have a motorized spinning beater brush at the base that strikes glass fragments at thousands of revolutions per minute, flinging razor-sharp splinters across the room, shredding the rubber drive belt, and embedding microscopic silica needles into the brush bristles that will subsequently spread into other rooms of your home. Always use a wet-dry shop vacuum or canister vacuum using only the bare plastic hose attachment, followed by pressing sticky duct-tape loops or an adhesive lint roller across the carpet pile.
What is the safest container for throwing away broken window glass?
Never put loose broken glass into a plastic garbage bag, as sharp shards slice straight through plastic and cause severe leg and hand lacerations when carrying the bag. Instead, place all broken glass inside a thick corrugated cardboard box (or a rigid 19-liter / 5-gallon plastic bucket), tape all seams of the cardboard box shut with heavy packing tape, write DANGER: BROKEN GLASS clearly on all sides with a thick black marker, and place it beside or inside your rigid curbside waste bin according to local municipal sanitation rules.
What should I do if someone has a large shard of window glass stuck deep in their arm or leg?
Never pull an embedded piece of glass out of a deep wound. The shard frequently plugs a nicked artery or large vein, and pulling it out can cause sudden, life-threatening hemorrhage while slicing surrounding nerves and tendons a second time. Leave the glass in place, stabilize it by building up thick pads of rolled gauze or clean folded cloth around both sides of the shard, wrap a bandage gently around the padding without pressing down on the glass tip, keep the limb immobilized, and call 911, 112, or 999 immediately.
How can I tell if my existing window glass is tempered safety glass or regular annealed glass?
Look closely at all four corners of the glass pane for a permanent sandblasted, acid-etched, or ceramic-fired rectangular manufacturer stamp (known in building codes as a "bug"). Certified tempered or laminated safety glass will carry a permanent corner mark listing the manufacturer name, the standard (such as ANSI Z97.1, CPSC 16 CFR 1201, or BS EN 12150), and the word "Tempered" or "Toughened." If there is no corner stamp and the broken pieces form long, pointed triangles rather than tiny 6-millimeter (1/4-inch) cubes, it is standard annealed float glass.
Sources checked¶
- Federal Emergency Management Agency (FEMA) and United States Fire Administration (USFA) (United States): Urban Search and Rescue (US&R) Structural Triage and Non-Destructive Window Boarding Procedures and Protect Your Property From High Winds (FEMA P-312).
- International Code Council (ICC) (United States / International): International Residential Code (IRC) Section R308 (Glazing and Hazardous Locations for Safety Glass) and International Building Code (IBC) Section 2406.
- Consumer Product Safety Commission (CPSC) (United States): 16 CFR Part 1201 Safety Standard for Architectural Glazing Materials.
- Occupational Safety and Health Administration (OSHA) (United States): 29 CFR 1910.133 (Eye and Face Protection) and 29 CFR 1910.138 (Hand Protection for Cut and Laceration Hazards).
- Health and Safety Executive (HSE) and HM Government Building Regulations (United Kingdom): Approved Document K (Protection from Falling, Collision and Impact: Glazing in Critical Locations) and BS 6262-4 Code of Practice for Glazing for Buildings.
- National Research Council of Canada (Canada): National Building Code of Canada (NBC) Part 9 Glass and Safety Glazing Requirements.