Skip to content

Keermuur uitpuilend, instorting van de helling van de tuin en wegspoelen van de oprit

Noodnummers verschillen per land. Deze pagina gebruikt 911, het nummer voor de Verenigde Staten en Canada. Veel andere landen gebruiken 112, 999 of een ander nummer. Zoek het nummer voor uw land.

A residential retaining wall that begins leaning outward, bulging at the center, or opening crescent-shaped tension cracks in the lawn behind it is an active geotechnical emergency holding back tens or hundreds of metric tons of saturated earth. One cubic meter of dry soil weighs roughly 1,400 to 1,600 kilograms (2,400 to 2,700 pounds per cubic yard), and when heavy rain, rapid spring snowmelt, or a leaking underground irrigation pipe saturates that soil, the weight climbs past 2,000 kilograms per cubic meter (3,400 pounds per cubic yard) while trapped pore water adds immense horizontal hydrostatic pressure pushing against the back of the wall. Even a modest 1.5-meter-tall (5-foot) backyard masonry or timber retaining wall stretching 10 meters (33 feet) along a driveway is fighting a lateral earth and water load exceeding 25,000 kilograms (55,000 pounds).

Homeowners routinely misjudge how fast a compromised retaining wall, hillside yard slump, or washed-out driveway culvert transitions from slow creep to instantaneous collapse. Walking along the base of a leaning stone or concrete block wall to push on it, parking a vehicle on the upper terrace near the edge of a bulging wall, or driving across a driveway culvert whose underlying gravel has been scoured away by flash runoff has killed or trapped thousands of residents worldwide. Taking disciplined action in the first ten minutes, establishing a strict 1.5-times-wall-height collapse exclusion zone, diverting surface water away from the upper slope tension cracks, removing vehicle surcharge weight from the top terrace, and checking for sheared underground gas or water utilities, protects your family and house foundation from a sudden earth slide.

Crushing earth loads and severed underground utility lines

Never stand, walk, or work in front of a bulging, leaning, or cracking retaining wall, and never attempt to prop up a masonry or timber retaining wall with wooden two-by-fours from the front. When a saturated retaining wall fails by overturning or base sliding, tens of thousands of kilograms of concrete blocks and wet clay soil crash down across a distance equal to 1.5 times the height of the wall in less than a second. If a hillside slump or driveway washout exposes or pulls on buried natural gas lines, water mains, or electrical conduits, evacuate the area immediately and call your utility provider and local emergency services.

Doe dit nu

  1. Clear everyone out of the "1.5x Height" collapse zone below the wall and off the top edge above it. Measure or estimate the vertical height of the retaining wall or steep slope (\(H\)). Barricade a strict safety perimeter extending at least 1.5 times the wall height (\(1.5 \times H\)) outward from the bottom toe of the wall AND 1.5 times the wall height back from the top crest of the wall. For a 2-meter-tall (6.5-foot) wall, keep all people, children, and pets at least 3 meters (10 feet) away from both the bottom face and the top terrace edge.
  2. Move vehicles, trailers, and heavy equipment off the upper terrace or undermined driveway immediately (only if safe). A parked passenger car or pickup truck sitting on the soil wedge behind a retaining wall adds 1,800 to 3,500 kilograms (4,000 to 7,700 pounds) of live surcharge load that pushes directly outward against the failing wall face. If the pavement is not actively cracking or sinking beneath your feet, move cars off the upper terrace and out from below the wall immediately. Never drive across a driveway bridge or culvert pipe if water is overtopping the pavement or if the asphalt edges are caving inward.
  3. Shut off irrigation systems, swimming pool backwash lines, and leaking yard pipes. Walk to your irrigation controller and turn all lawn sprinklers and drip zones OFF. If a swimming pool, hot tub, or ornamental pond sits on the slope above the retaining wall or hillside slump, check whether a leaking pool return pipe or filter backwash hose is pumping thousands of liters of water into the hillside soil.
  4. Divert roof downspouts and surface runoff away from the top of the wall and out of ground cracks. The fastest way to stop a creeping retaining wall or yard slump from collapsing during a rainstorm is to stop additional surface water from pouring into the soil wedge behind the wall. Attach 3- to 6-meter (10- to 20-foot) flexible corrugated plastic extensions to any roof gutter downspouts discharging near the top of the slope so roof water drains far away from the hillside.
  5. Cover open crescent-shaped ground cracks at the top of the slope with waterproof plastic tarps. Look at the lawn, soil, or pavement 0.5 to 3 meters (1.5 to 10 feet) behind the top of the bulging wall or slumping hillside. If you see curved, crescent-shaped cracks opening in the dirt or asphalt (headscarp tension cracks), lay heavy 6-mil polyethylene plastic sheeting or waterproof tarps flat over the cracked ground and anchor the uphill edge with sandbags or bricks so rainwater slides harmlessly over the cracks instead of pouring straight down into the slip plane like a hydraulic jack.
  6. Inspect your house foundation and smell for natural gas if the slope sits near your home. If the failing retaining wall or yard slump is within 6 meters (20 feet) of your house, check your basement walls, garage slab, and exterior brickwork for new diagonal stair-step cracks, sticking doors, or separated porch steps following our gids voor structurele schade en instorting. If you smell rotten-egg mercaptan odor or hear hissing soil near a slope movement, evacuate immediately and follow our gas leak emergency guide.

Retaining wall and slope emergency triage flowchart

Use this geotechnical triage decision tree to evaluate the severity of a retaining wall bulge, hillside yard slump, or driveway culvert washout and choose the safest immediate stabilization response.

flowchart TD
    Start["Retaining Wall Bulge, Hillside Yard Slump,<br/>or Driveway Culvert Washout Detected"] --> Zone["1. Establish 1.5x Wall/Slope Height Exclusion Zone<br/>Above and Below Failure Area"]
    Zone --> Surcharge["2. Remove Parked Vehicles from Top Terrace<br/>and Clear People/Cars Below Wall"]
    Surcharge --> HazardType{"3. Which geotechnical emergency is occurring?"}

    HazardType -->|"A. Retaining wall leaning >2 to 5 degrees,<br/>belly bulge, or dry weep holes during rain"| WallBranch{"Is wall movement active/cracking<br/>or threatening a house?"}
    HazardType -->|"B. Crescent-shaped tension crack in yard<br/>and tilted trees/fences on hillside"| SlumpBranch{"Is muddy water seeping out<br/>at the bottom toe of the slope?"}
    HazardType -->|"C. Driveway culvert pipe plugged,<br/>water overtopping road, or asphalt undermined"| CulvertBranch["Barricade Driveway Immediately:<br/>Do NOT drive across undermined asphalt<br/>or enter submerged culvert inlet"]

    WallBranch -->|"Active cracking, >5 cm (2 in) tilt,<br/>or supporting house foundation"| EvacWall["Imminent Wall Collapse:<br/>Stay out of drop zone; call geotechnical/structural engineer;<br/>notify city building dept if near street/neighbor"]
    WallBranch -->|"Slow creep, plugged weep holes,<br/>no active falling blocks"| DrainWall["Relieve Hydrostatic Pressure Safely:<br/>Divert roof downspouts, tarp soil behind wall,<br/>clear plugged weep holes from the side with long rod"]

    SlumpBranch -->|"Yes: Toe bulging and muddy springs,<br/>or loud root snapping sounds"| ActiveSlide["Imminent Landslide / Debris Flow:<br/>Evacuate downhill structures immediately;<br/>call 911 / 112 / 999 and check utilities"]
    SlumpBranch -->|"No: Dry tension crack at crest"| TarpSlump["Tarp Headscarp Tension Cracks:<br/>Lap waterproof 6-mil plastic over cracks;<br/>NEVER dump fill dirt onto top of slump"]

    CulvertBranch --> CulvertFix["Wait for Water to Recede:<br/>Clear upstream trash rack only from high dry bank;<br/>inspect pipe bedding scour before driving"]

Geotechnical mechanics: why retaining walls and yard slopes fail

A retaining wall is not a decorative fence; it is a gravity dam engineered to resist the downward and outward wedge of soil behind it (active earth pressure). Nearly 90 percent of all residential retaining wall collapses and backyard slope failures are triggered by water, not by the weight of the dry dirt alone.

The 4 structural failure modes of a retaining wall

Geotechnical engineers evaluate a distressed retaining wall by identifying which of four mechanical failure modes is underway:

  1. Overturning (Rotational tilt around the front toe):
  2. Lateral pressure from saturated clay soil or frost heave high on the back of the wall pushes the top of the wall outward, causing the entire wall to lean forward at an angle while pivoting around its bottom front edge (the toe).
  3. Critical tipping point: Most segmental concrete block and timber walls are built with a purposeful backward lean into the hill (batter) of 2 to 7 degrees. Once a vertical wall tilts forward past vertical, its center of gravity shifts outside the middle third of its base footing, and overturning accelerates rapidly.
  4. Sliding (Horizontal shear at the base):
  5. The wall stays relatively vertical, but the entire bottom course of blocks, timbers, or poured concrete footing slides forward across the wet clay soil beneath it because the soil under the base has turned slick with water and lost frictional grip.
  6. You will see a gap opening behind the wall and a ridge of sod or gravel bunched up in front of the bottom course.
  7. Internal Shear / Belly Bulging (Mid-height blowout):
  8. Common in dry-stacked stone walls, unreinforced concrete cinder-block (CMU) walls, interlocking landscaping blocks lacking geogrid reinforcement fabric, and rotting railroad-tie timber walls.
  9. The top and bottom courses stay roughly in place, but the middle third of the wall bows outward like a pregnant belly, mortar joints crack horizontally, wood timbers splinter, or individual stones begin popping out of the face. A mid-height belly bulge is the most dangerous failure mode because the wall explodes outward without gradual tipping.
  10. Deep-Seated Global Slope Failure (Rotational slump beneath the wall):
  11. Sometimes the retaining wall itself is built solidly, but the entire hillside underneath and behind the wall shears along a deep curved spoon-shaped slip plane 2 to 6 meters (6.5 to 20 feet) underground.
  12. Clues include a curved crescent crack (headscarp) opening in the yard far behind the wall, combined with the ground in front of the bottom of the wall heaving upward as the deep soil cylinder rotates.

Why clogged weep holes turn rain into a hydraulic ram

Behind every properly built concrete, brick, stone, or timber retaining wall sits a column of crushed drainage stone and a perforated drain pipe (French drain / footing drain), along with row of small holes or vertical slots spaced every 1.2 to 2.4 meters (4 to 8 feet) along the bottom front face of the wall called weep holes.

  • Wanneer huilgaten en grindafvoeren goed werken, wordt het regenwater dat in de grond achter de muur sijpelt onmiddellijk via de huilgaten naar de voortuin afgevoerd, zodat zich nooit water achter de muur ophoopt.
  • Wanneer huilgaten verstopt raken door modder, boomwortels, geotextiel filterweefsel verstopt met kleislib, wespen- of muizennesten, of wanneer een huiseigenaar de huilgaten per ongeluk dichtmaakt om er zichtbaar uit te zien, vult zich een verborgen ondergronds reservoir met water achter de muur tijdens een stortbui.
  • Hydrostatische drukfysica: Water duwt horizontaal tegen de achterkant van een muur in elke richting met een druk gelijk aan \(\gamma_w \times h\) (ongeveer 9,8 kilopascal per meter diepte, of 62,4 pond per vierkante voet voor elke voet waterdiepte). Een verstopte muur met daarachter 1,8 meter opgesloten water ondervindt meer dan het dubbele van de horizontale duwkracht van droge grond, terwijl hetzelfde water kleideeltjes smeert en de interne schuifsterkte van de grond tot modder vermindert.

Diagnostische vergelijkingstabel: beoordeling van de ernst van defecten aan muren, hellingen en opritten

Gebruik deze veldinspectiematrix vanuit een veilig uitkijkpunt buiten de instortingszone om te bepalen of u te maken heeft met kleine seizoensbewegingen of een dreigende catastrofale mislukking.

Structureel kenmerk Kleine/vroege nood (monitoring en planning van reparatie) Matige actieve beweging (onmiddellijke wateromleiding en advies van een ingenieur) Critical Imminent Collapse (Evacuate Zone & Call Authorities)
Kerende muur leun-/kantelhoek Wall still leans slightly backward into hill (batter) or sits plumb within 1 centimeter (⅜ inch) of vertical Wall has tilted forward past vertical by 2.5 to 5 centimeters (1 to 2 inches) per 1.2 meters (4 feet) of height Wall tilts forward by more than 5 to 7.5 centimeters (2 to 3 inches), or mid-wall belly bulge exceeds 4 centimeters (1.5 inches)
Mortar joints, concrete cracks, or timbers Hairline vertical shrinkage cracks under 2 millimeters (1/16 inch) wide in poured concrete or mortar joints Horizontal or stair-step cracks 3 to 10 millimeters (⅛ to ⅜ inch) wide; wood timbers soft with rot or bowing between deadmen Scheuren breder dan 12 millimeter (½ inch) die in de loop van de tijd meetbaar groter worden; blokken die uit lijn verschuiven; hout dat luid knakt
Weep hole flow during/after heavy rain Helder water dat tijdens en na regen gestaag uit alle huilgaten druppelt Slechts één of twee huilgaten druipen, terwijl andere kurkdroog zijn, of modderig bruin water dat onder druk naar buiten spuit Alle gaten drogen volledig op tijdens een zware regenbui terwijl water over de bovenste top van de muur stroomt of omhoog borrelt bij de basisteen
Upper lawn / terrace behind wall Enigszins ondiepe bezinkgoot direct achter de bovenste blokken vanwege opvulverdichting Duidelijke val van 2,5 tot 7,5 centimeter (1 tot 3 inch) en spanningsscheuren 0,5 tot 2 meter (1,5 tot 6,5 voet) achter de muur Gebogen halvemaanvormige kopskarperdaling van 10 tot 30+ centimeter (4 tot 12+ inch); hekken uit elkaar getrokken; bomen die naar voren of naar achteren kantelen
Hillside yard slope clues Minor surface sheet erosion or shallow rills in bare mulch after a storm Pistol-butt (J-curved) tree trunks, tilted utility poles/retaining posts, and soggy ground halfway down the slope Muddy water springs breaking out near the bottom toe of the slope, ground heaving at the base, or audible popping of tree roots
Driveway & culvert pipe status Minor gravel wash along shoulder edges; culvert pipe flowing less than half full Water ponding on uphill side of driveway; erosion eating into gravel shoulder within 30 centimeters (12 inches) of pavement edge Water overtopping driveway, whirlpool vortex at plugged culvert inlet, or hollow cavern washed out underneath asphalt edge

Step-by-step emergency stabilization for a failing retaining wall or yard slump

Once a retaining wall is bulging or a hillside lawn has split open in a rotational slump, you cannot push the wall back into place, and you must never stand in front of it. However, you can safely perform three high-impact stabilization measures from outside the hazard zone that stop water from driving the failure to total collapse.

Step 1: Set up the "Tell-Tale" movement monitor (So you know if it is moving right now)

During an ongoing storm, the human eye cannot easily tell whether a wall crack or lawn slump moved 6 millimeters (¼ inch) in the last hour or has been sitting stationary for months. Set up two simple mechanical gauges from a safe position:

  1. The Two-Stake Lawn Slump Gauge (For hillside and top-of-wall cracks):
  2. Stand on the stable, uncracked uphill ground behind the tension crack (never step onto the downhill sliding block between the crack and the wall edge).
  3. Drive one wooden stake into the stable uphill ground 60 centimeters (2 feet) behind the crack, and reach across to drive a second stake into the moving soil block just downhill of the crack.
  4. Stretch a tight string or measuring tape between the two stakes, mark the exact distance with a permanent marker (for example, 100.0 centimeters), and check it with a flashlight every 30 to 60 minutes from the safe uphill side. If the distance between the stakes is growing by 6 millimeters (¼ inch) or more per hour during rain, the slope is in active failure and collapse is imminent.
  5. The Tape-Bridge or Glass-Slide Crack Monitor (For concrete/masonry wall ends):
  6. From the safe side end of a concrete wall (never standing in front of the bulging center), place two dabs of fast-setting epoxy or exterior duct tape across a vertical crack and draw a straight vertical line across the tape with a ruler and marker. Any horizontal separation or vertical shearing splits the line visibly.

Step 2: Waterproof and armor the upper tension cracks (The Tarp Shingle Technique)

When a retaining wall leans forward or a hillside slumps slightly, a deep vertical crack opens in the earth behind it. If rainwater or snowmelt runs off your yard and pours down into that open crack, the crack fills with water like a narrow vertical standpipe, multiplying the outward hydraulic force on the wall by 300 to 500 percent.

  1. Working strictly from the stable uphill side (staying at least 1.5 meters / 5 feet back from the edge of the wall), unroll heavy 6-mil (0.15-millimeter) polyethylene plastic sheeting or waterproof tarps over the entire cracked zone and extending at least 2 meters (6.5 feet) uphill past the highest crack.
  2. Shingle the overlaps downhill: If using multiple tarps, always lap the upper tarp over the top of the lower tarp (like roof shingles) so water runs smoothly across the seam without leaking underneath.
  3. Cut a shallow 10-centimeter (4-inch) V-trench along the uphill edge of the tarp, tuck the top edge of the plastic into the trench, and line it with sandbags or soil so surface sheet water cannot sneak under the uphill edge of the plastic.
  4. Direct the downhill edge of the tarp sideways toward a stable grassy swale or storm drain away from the compromised wall section.

Never dump gravel or fill dirt into a slump crack at the top of a failing slope

One of the most dangerous mistakes homeowners and landscapers make when a backyard patio or lawn drops 15 centimeters (6 inches) along a hillside slump is ordering a truckload of topsoil, gravel, or concrete to fill the sunken top back up to level. Adding soil or concrete at the top (head) of a rotational slump adds massive dead weight to the exact driving wedge that is pushing the hillside down. Never add weight to the top of a failing slope or behind a bulging wall; weight may only be added at the bottom toe (such as an engineered rock buttress) under the direction of a licensed geotechnical engineer.

Step 3: Clear plugged weep holes from the side using a long rod

If a retaining wall is stable enough that no blocks are falling and no active cracking is occurring, but you notice that its bottom weep holes are dry or plugged with mud and wasp nests while the soil behind the wall is waterlogged:

  1. Stand outside the 1.5x Height collapse zone to the side of the wall or reach diagonally with a long 2.4- to 3-meter (8- to 10-foot) piece of rigid PVC pipe, steel rebar, or bamboo pole.
  2. Poke the rod gently into the mouth of each bottom weep hole to break through mud crusts, insect mud dauber plugs, or root mats, or direct a gentle stream from a garden hose nozzle taped to a long pole into the weep hole for 5 seconds to flush out silt.
  3. If dark muddy water begins gushing out of the cleared weep hole, step back and let the trapped water table drain down naturally. (Note: If clearing a weep hole washes out large quantities of clean backfill sand or gravel continuously, a filter cloth behind the wall has torn, creating an underground cave; stop probing and call an engineer.)

Driveway washouts, undermined pavement, and plugged culvert emergencies

Rural, suburban, and hillside homes frequently cross a drainage ditch, seasonal creek, or ravine via a corrugated metal, HDPE plastic, or concrete culvert pipe buried underneath the driveway. During intense rainstorms or flash floods (see our flash floods guide en landslides guide), driveway culverts fail in three deadly ways:

1. The Hidden Asphalt Bridge Trap (Undermined pavement)

Asphalt and concrete driveways are rigid crust slabs 5 to 10 centimeters (2 to 4 inches) thick that rely entirely on the compacted crushed stone base underneath them to support the 2,000-kilogram (4,400-pound) weight of an automobile.

  • How piping and scour hollow out a driveway: When tree branches and leaves plug the uphill entrance of a driveway culvert pipe, water backs up into a deep pond on the uphill side of the driveway. Forced by hydraulic pressure, water begins seeping around the outside of the metal or plastic culvert pipe through the gravel bedding (hydraulic piping). Within 30 minutes, the rushing water washes away all the gravel and dirt underneath the driveway while leaving the top 5-centimeter (2-inch) shell of black asphalt hanging in mid-air like an unsupported eggshell bridge.
  • Why you must never drive or walk across it: From the driver's seat, the blacktop driveway looks completely flat and intact (or covered by only 2 centimeters of running water). The instant a car's front tires roll onto the unsupported asphalt crust, the pavement punches through into a 1.5-meter-deep (5-foot) washed-out chasm, flipping the vehicle nose-first into rushing floodwater.
  • Onmiddellijke actie:
  • Barricade both ends of the driveway immediately using orange cones, trash cans, bright flagging tape, or parked vehicles parked well back on solid ground so delivery trucks, family members, or emergency vehicles cannot accidentally drive onto the undermined span.
  • Probe the edges of the pavement from safe, dry ground using a long wooden pole or shovel handle to check whether the gravel shoulder underneath the asphalt edge has washed away.

2. The Culvert Inlet Suction Vortex (Never clear a submerged culvert during a storm)

When water backs up 1 to 2 meters (3 to 6.5 feet) deep behind a plugged driveway culvert pipe, homeowners are often tempted to wade into the ditch with a rake to pull branches off the submerged pipe opening.

Lethal differential pressure entrapment (Delta-P hazard)

Never wade into ponded water near the uphill intake of a flooded driveway culvert pipe, and never reach your hands, feet, or a short rake near a submerged culvert opening. A 45-centimeter (18-inch) culvert pipe under just 1.2 meters (4 feet) of water head generates over 700 kilograms (1,500 pounds) of suction force (differential pressure / Delta-P). If the branch plug suddenly shifts or your boot slips near the intake vortex, the water pressure pins a human body against the pipe mouth with a force that four adults with ropes cannot pull free. Wait until the storm ends and the ponded water drains completely before clearing a culvert inlet.


Protecting utilities and foundations when a yard slope or wall shifts

Soil movement does not just move dirt and stone; a lateral shift of just 5 centimeters (2 inches) in a yard slope or driveway edge will shear rigid underground pipes and conduits passing through the slide zone.

  1. Buried natural gas service lines and propane lines:
  2. Check where your street gas main enters your property or where the buried copper/polyethylene line from your backyard propane tank runs to your house.
  3. If the ground along that path has cracked, slumped, or bulged behind a failing retaining wall, shut off the propane tank service valve (or evacuate and call the gas utility emergency number if you smell gas or see soil pulling away from the house gas meter riser).
  4. Municipal water service lines and private septic systems:
  5. A shifting slope frequently snaps underground PVC or copper water service lines between the street meter and the house, pumping pressurized water straight into the slide plane and accelerating a catastrophic landslide. Look at the small spinning leak-indicator triangle on your street water meter while all indoor taps are off; if it is spinning, shut off the street curb stop valve immediately.
  6. If your septic tank or leach drainfield sits on a slumping slope, stop all indoor water use immediately so sewage effluent does not lubricate the hillside (see our handleiding voor septische systeemstoringen).
  7. Bergburenaansprakelijkheid en gemeentelijke voorrangsmelding:
  8. Als uw falende keermuur of helling op een heuvel grenst aan een openbaar trottoir, stadsstraat, steegje of het huis, de oprit of de slaapkamermuur van een bergafwaarts gelegen buurman, waarschuw dan onmiddellijk uw buurman in de benedenverdieping, persoonlijk of per telefoon, zodat zij familieleden uit de kamers met uitzicht op de muur kunnen verplaatsen en hun geparkeerde auto's kunnen verplaatsen.
  9. Bel uw gemeentelijke bouwafdeling of de niet-dringende brandweer/openbare werken om een ​​bouwinspecteur van de stad of een gemeentelijke ingenieur te vragen als de muur een openbare weg of een aangrenzende constructie bedreigt.

Permanente technische reparaties: wat werkt en waarom doe-het-zelf-pleisters mislukken

Zodra de noodsituatie is gestabiliseerd en de grond is opgedroogd, kan een keermuur die voorbij de verticale stand is gekanteld, in het midden is opgezwollen of zijn basiswrijving heeft verloren kan niet worden gerepareerd door scheuren met mortel te dichten of schuin hout tegen de gevel te steunen.

  • Waarom het repareren van scheuren in een betonnen keermuur de instorting verergert: het opvullen van open scheuren in een betonnen of blokkeermuur met hydraulisch cement dicht de enige overgebleven ontsnappingsopeningen af ​​waar opgesloten water naar buiten stroomde, waardoor de hydrostatische druk achter de muur toenam.
  • Goedgekeurde geotechnische reparatiemethoden (ontworpen door een erkende professionele ingenieur [PE] voor muren van meer dan 1 tot 1,2 meter / 3 tot 4 voet hoog):
  • Volledig afbreken en herbouwen met geogrid bodemversterking en drainage: Uitgraven van de defecte muur, installeren van een geperforeerde PVC-voetafvoer ingekapseld in gewassen hoekige #57 steenslag gewikkeld in niet-geweven geotextiel filterweefsel (om te voorkomen dat kleislib het grind vervuilt), en het inbedden van horizontale lagen van zeer sterk polymeer geogridgaas dat zich 1,5 tot 3 meter (5 tot 10 voet) uitstrekt terug in verdichte grindaanvulling, zodat de hele bodemmassa fungeert als een enkel monolithisch zwaartekrachtblok.
  • Spiraalvormige bevestigingsankers of grondspijkers: Voor gestorte betonnen of zware houten muren die structureel intact zijn maar beginnen te leunen, boren gespecialiseerde funderingsaannemers lange stalen schroefvormige bevestigingsstangen door de wand in een neerwaartse hoek van 4 tot 9 meter (13 tot 30 voet) terug in stabiel gesteente of ongestoorde aarde voorbij het glijvlak, waarbij ze de voorkant vastzetten met zware stalen lagerplaten.
  • Gabion basket of riprap teensteun: Voor afzakkende hellingen op hellingen zonder een formele muur, het uitgraven van de onstabiele teen en het stapelen van zware gegalvaniseerde draadkooien gevuld met 10 tot 20 centimeter (4 tot 8 inch) hoekige steengroeven (gabionmanden) waardoor grondwater vrij uit de heuvel kan stromen terwijl de teen met een enorm eigen gewicht wordt verankerd.

Veelgestelde vragen

Hoe ver moet ik verwijderd blijven van een scheve of uitpuilende keermuur?

Geotechnische ingenieurs en reddingsdiensten handhaven een minimale instortingszone die gelijk is aan 1,5 keer de verticale hoogte van de keermuur, zowel naar buiten gemeten vanaf de onderste voorste teen van de muur als naar achteren vanaf de bovenste top van de muur. Als een muur van stenen of betonnen blokken bijvoorbeeld 2 meter hoog is, moet je alle mensen, huisdieren en geparkeerde auto's op minimaal 3 meter afstand van de voorkant van de muur en 3 meter van de bovenrand houden, omdat een falende muur en de wig van verzadigde aarde erachter in minder dan twee seconden naar buiten glijden over die hele voetafdruk.

Kan ik een scheve metselwerk- of houten keermuur verstevigen met houten 2x4 palen of vijzels?

Nee, probeer nooit een steunmuur van leunsteen, betonblok of spoorbielzen vanaf de voorkant te ondersteunen met behulp van houten schoren of vijzels. Zelfs een klein stuk verzadigde heuvelgrond van 1,2 meter hoog oefent 5.000 tot 15.000 kilogram zijdelingse kracht uit die dimensionale houten twee bij vier, zoals tandenstokers, zal laten knappen en versplinterd hout en betonblokken zal lanceren op iedereen die in de buurt van de muur staat; de enige veilige noodmaatregelen zijn het opruimen van de instortingszone, het verwijderen van voertuigen van het bovenste terras en het wegleiden van oppervlaktewater van de grond achter de muur.

Waarom is mijn keermuur tijdens een regenbui plotseling gaan uitpuilen of instorten, nadat hij 15 jaar goed had gestaan?

Keermuren bezwijken bijna altijd plotseling na jaren van stabiliteit, omdat de begraven grindafvoerkolom en de bodemgaten achter de muur gedurende een decennium geleidelijk verstoppen met fijn kleislib, boomwortels en rottend organisch materiaal. Zodra het verborgen afvoerpad is afgesloten, vult de volgende zware regenbui of smeltende sneeuw in de lente de grond achter de muur met opgesloten grondwater, waardoor tegelijkertijd het gewicht van de grond wordt verdubbeld, een enorme horizontale hydrostatische waterdruk tegen de achterkant van de muur wordt toegevoegd en de grond onder de bodem verandert in gladde modder die zijn wrijvingskracht verliest.

Dekt de verzekering van huiseigenaren een ingestorte keermuur of het wegspoelen van de oprit?

Standaard verzekeringspolissen voor huiseigenaren sluiten vrijwel overal schade uit die wordt veroorzaakt door grondverschuivingen, aardverschuivingen, bodemdaling, hydrostatische ondergrondse waterdruk en afvoer van oppervlaktewater. Dit betekent dat een keermuur die instort door met regen verzadigde grond of een door een storm weggespoelde oprit, zelden wordt gedekt, tenzij de muur werd getroffen door een omgevallen boom of voertuig, of u een afzonderlijke goedkeuring voor overstroming of grondverzet heeft. Als een plotseling gesprongen leiding in uw tuin echter de oorzaak is van de wegspoeling, dekken sommige polissen de resulterende toegangsreparaties; Maak altijd een grondige foto van de locatie en controleer uw polisverklaringen voordat u met de opgravingen begint.


Bronnen gecontroleerd

  • United States Geological Survey (USGS): The Landslide Handbook: A Guide to Understanding Aardverschuivingen (rotatie-inzinkingen, spanningsscheuren in de kopskarper, omleiding van oppervlaktewater en waarschuwingssignalen van dreigend falen van de helling).
  • Federal Highway Administration (FHWA, Ministerie van Transport van de Verenigde Staten): Ontwerp en constructie van mechanisch gestabiliseerde aardmuren en versterkte bodemhellingen (FHWA-NHI-10-024) en Richtlijnen voor het falen van duikers en hydraulische leidingen.
  • International Code Council (ICC): International Building Code (IBC) Sectie 1807 (Keermuren) en International Residential Code (IRC) Sectie R404.4 (veiligheidsfactoren voor kantelen en glijden, afvoervereisten en drempels voor bouwvergunningen voor muren van meer dan 1,2 meter/4 voet).
  • National Concrete Masonry Association (NCMA): Ontwerphandleiding voor segmentale keermuren (hydrostatische drukeffecten, verstoppingsmechanismen van gaten en geotextiel, en levende toeslagen van geparkeerde voertuigen).
  • Health and Safety Executive (HSE, Verenigd Koninkrijk) en Institution of Structural Engineers (IStructE): Stabiliteit van metselwerk keermuren: inspectie, openbare uitsluitingszones en instortingspreventie.
  • Federal Emergency Management Agency (FEMA, Verenigde Staten): Handleiding voor huiseigenaren over het beperken van aardverschuivingen en hellingen en veiligheidsregels voor overstromingsduikers.

Gerelateerde handleidingen