Skip to content

Electric shock first aid: what to do and what to avoid

Emergency numbers differ by country. This page uses 911, the number for the United States and Canada. Many other countries use 112, 999, or another number. Find the number for your country.

Electrical injuries are among the most deceptive and complex emergencies in trauma medicine. While the visible skin contact points may appear as minor, pinpoint surface burns, electrical current passing through the human body converts into intense internal thermal energy along deep anatomical pathways. Within milliseconds, household or industrial current can induce involuntary muscle paralysis that locks the victim onto the live conductor, trigger lethal ventricular fibrillation or respiratory arrest, coagulate deep vascular networks, cook periosteal skeletal muscle against heated bone, and fracture the spine through violent tetanic contractions.

The absolute first rule of any electrical emergency is rescuer safety: touching a person who remains in contact with an energized electrical source turns you into an immediate secondary casualty. Knowing how to isolate household and commercial power, separate a low-voltage victim using dry non-conductive insulators, escape the concentric ground-voltage rings (step potential) of a downed high-voltage utility line, initiate immediate cardiopulmonary resuscitation (CPR), and recognize delayed internal complications such as rhabdomyolysis and compartment syndrome saves lives.

Sala boye sikoyo

  1. Do not touch the victim with your bare hands, clothing, or any metal or wet object while they are still touching the electrical source. The human body is an electrolytic conductor; grabbing an electrified person transfers the live current directly through your own heart and nervous system.
  2. Call emergency services immediately and state that an electrical injury has occurred. Call your local emergency number (911 in the United States and Canada, 112 across the European Union, 999 in the United Kingdom) or check banimero ya mbalakaka, and request both paramedics and the electric utility company if high-voltage lines are involved.
  3. Shut off the electrical power source immediately if it is low-voltage household or commercial power (under 1,000 volts). Flip the main circuit breaker switch at the electrical service panel, unscrew the fuse, switch off the wall socket switch (where equipped), or pull the insulated rubber plug from the outlet if the cord is undamaged and away from water.
  4. Stay at least 10 to 20 meters (33 to 65 feet) back if the source is high-voltage (over 1,000 volts), a downed overhead power line, or lightning. Never attempt to pry a high-voltage wire off someone with a broomstick or wooden branch, because high-voltage electricity arcs through the air and travels down non-conductive poles; wait until utility technicians confirm the grid is de-energized and grounded.
  5. If low-voltage household power cannot be switched off immediately, push the victim or wire away using a completely dry, non-conductive object. Stand on a dry insulating surface (such as a rubber doormat, dry wooden board, or thick stack of newspapers) and use a dry wooden broom handle, fiberglass pole, dry PVC pipe, or looped dry cotton rope to break contact.
  6. Check responsiveness and breathing the instant the victim is clear of the electricity, and start CPR immediately if needed. If the person is unresponsive and not breathing normally (or only taking irregular agonal gasps), begin cardiopulmonary resuscitation (CPR) at 100 to 120 compressions per minute and attach an Automated External Defibrillator (AED) as soon as one arrives; if they are breathing, cool any visible burns with cool running water for 20 minutes and keep their neck and spine still.
flowchart TD
    Start["Person in Contact with Electrical Source"] --> HVCheck{"Is it High Voltage (>1,000 V), a downed power line, or wet environment?"}
    HVCheck -->|"Yes: High Voltage or Downed Line"| HVProtocol["Keep 10 to 20 meters (33 to 65 feet) away; NEVER approach or use poles"]
    HVProtocol --> CallUtil["Call 911 / 112 / 999 and electric utility; shuffle with feet together if inside zone"]
    HVCheck -->|"No: Low Voltage Household (110 V to 240 V)"| CutPower{"Can you safely shut off the breaker or unplug the cord?"}
    CutPower -->|"Ɛɛ"| PowerOff["Flip main circuit breaker to Off or pull insulated plug"]
    CutPower -->|"Te"| Insulate["Stand on dry rubber or wood; push wire or victim away with dry wood or plastic tool"]
    PowerOff --> Assess["Victim Free of Current: Check responsiveness and breathing for 10 seconds"]
    Insulate --> Assess
    Assess --> BreathCheck{"Is the victim responsive and breathing normally?"}
    BreathCheck -->|"No (Unresponsive / Agonal gasps)"| StartCPR["Bandá CPR (30:2 to Maboko kaka) na 100 kino 120 bpm mpe pakola AED mbala moko"]
    BreathCheck -->|"Yes (Breathing normally)"| TraumaCare["Immobilize spine if fallen, cool burns with cool running water for 20 min, transport to ER"]

Physics and pathophysiology of electrical trauma

When an electrical circuit forms across the human body, the severity of cellular and organ destruction is governed by six physical variables summarized by Ohm's Law (\(I = V / R\), where current equals voltage divided by resistance) and Joule's First Law of Heating (\(Q = I^2 \times R \times t\), where thermal heat generated equals the square of the current multiplied by tissue resistance and contact duration):

  1. Amperage (Current intensity in milliamperes, mA): Amperage is the primary physiological killer, determined by the driving voltage divided by skin and internal tissue resistance.
  2. Voltage (Electrical potential in volts, V): Divided clinically into low voltage (under 1,000 volts, such as 120 V North American mains, 230 V European/UK/Australian mains, and 400 V three-phase commercial wiring) and high voltage (1,000 volts and above, such as overhead utility distribution lines carrying 4,160 V to 34,500 V and transmission towers carrying 115,000 V to 765,000 V).
  3. Resistance (Impedance in ohms, \(\Omega\)): Dry, calloused human palms offer high resistance (up to 40,000 to 100,000 ohms), which limits current flow. However, wet skin, sweaty skin, immersed skin in a bathtub, or broken skin drops epidermal resistance down to 500 to 1,000 ohms. At 1,000 ohms of wet skin resistance, touching a standard 120-volt or 230-volt bathroom appliance delivers 120 to 230 milliamperes directly into the bloodstream, which is more than enough to trigger instant cardiac arrest.
  4. Type of current: Alternating Current (AC) versus Direct Current (DC).
  5. Anatomical pathway (Transthoracic vs vertical): Current travels along the path of least electrical resistance (blood vessels, nerves, and muscles) from the entrance contact point to the ground exit point:
  6. Hand-to-hand (horizontal transthoracic pathway): Current enters one hand, crosses directly through the mediastinum and heart, and exits the opposite hand. This pathway carries the highest mortality rate (~60 percent in high-voltage contacts) due to direct myocardial fibrillation.
  7. Hand-to-foot (vertical pathway): Current travels from the upper extremity through the thorax, abdominal organs, and leg to the floor.
  8. Foot-to-foot (stride or step potential pathway): Current enters one foot, crosses the pelvis, and exits the other foot.
  9. Duration of contact (\(t\)): The longer the body stays connected to the wire, the more thermal heat accumulates inside deep tissues and the skin breaks down, dropping resistance further and accelerating current inflow.

Physiological effects of 50/60 Hz AC current by milliamperes

Current Intensity (mA, 1-second contact) Physiological Effect on the Human Body Clinical Outcome
1 to 3 mA Threshold of sensory perception Mild tingling sensation at the fingertips; no tissue damage
5 to 10 mA Painful sensory shock Sharp pain; normal adult can still voluntarily release their grip ("let-go" current)
10 to 20 mA The "Let-Go" Threshold (Flexor Tetany) Involuntary tetanic contraction of forearm flexor muscles locks the hand tightly around the wire; victim cannot let go
20 to 50 mA Thoracic and Diaphragmatic Tetany Continuous paralysis of the diaphragm and intercostal breathing muscles; causes respiratory arrest and asphyxiation if contact continues
50 to 100 mA Ventricular Fibrillation (V-Fib) Threshold Electrical current strikes during the vulnerable cardiac T-wave repolarization window, throwing the heart into chaotic fibrillation
1,000 to 4,000 mA (1 to 4 Amps) Sustained Myocardial Contraction (Asystole) and Deep Thermal Burns Complete clamping standstill of the heart muscle combined with massive deep internal tissue cooking

Alternating Current (AC) versus Direct Current (DC)

Clinical and Physical Feature Alternating Current (AC: 50 Hz / 60 Hz) Direct Current (DC)
Common Real-World Sources Household wall outlets (120 V / 230 V), kitchen appliances, power tools, commercial HVAC, overhead utility lines Automotive and EV battery packs (12 V to 800 V), solar photovoltaic arrays, electrified subway third rails, arc welders, lightning
Skeletal Muscle Response Continuous tetanic spasm ("No-Let-Go" phenomenon): Because current reverses direction 50 to 60 times per second, forearm flexor muscles contract continuously, clamping the victim's fist onto the live wire Single violent ballistic contraction: Produces a single massive muscle spasm that frequently throws the victim several meters backward away from the power source
Primary Cardiac Arrhythmia Ventricular Fibrillation (V-Fib): 3 to 5 times more dangerous than DC at low voltages because the 50/60 Hz cycle repeatedly crosses the vulnerable cardiac repolarization phase Ventricular Asystole (Cardiac Standstill): High-voltage DC depolarizes the entire myocardium at once, stopping the heartbeat completely
Associated Trauma Profile Prolonged contact time leading to deep internal thermal necrosis, respiratory asphyxiation, and local full-thickness entrance/exit burns Shorter contact time, but high rates of blunt orthopedic trauma (skull fractures, cervical spine fractures, ruptured spleen, long-bone fractures) from being thrown or falling off ladders

Safe rescue protocols: breaking electrical contact

Danger

Never approach within 10 meters (33 feet) of a downed overhead power line, substation transformer, electrified train rail, or any high-voltage industrial source exceeding 1,000 volts, and never attempt to move a high-voltage wire with a wooden broom, tree branch, or plastic tool. High-voltage electricity ionizes the air to jump (arc) across open space and travels directly down the surface moisture of wood or plastic into your body.

1. Low-voltage household and workplace rescue (Under 1,000 Volts)

Ntango moto azali kokamwisa na aparɛyi ya ndako ya 120 volts to 230 volts, nsinga ya kobakisela, esaleli ya kura, to interrupteur oyo ezali na mbeba:

  1. Cut the power at the source first (Always the safest method):
  2. Run to the household electrical distribution panel (fuse box or breaker box) and flip the Main Breaker to the Off position, or flip the specific branch circuit breaker.
  3. In the United Kingdom, Europe, and Australia, wall sockets feature an individual rocker switch; if the wall socket is dry and you can reach it without touching the victim or appliance, flip the socket switch off with a dry non-conductive object and pull the plug.
  4. If the victim is holding an appliance in a wet area (bathroom floor, flooded basement, swimming pool deck, or wet lawn), never step onto the wet floor or touch the appliance cord. Shut off power exclusively at the main house breaker panel while standing on dry flooring.
  5. How to separate a victim when the breaker is unreachable:
  6. If you cannot reach the circuit breaker within seconds and the victim is locked in tetanic spasm on a dry indoor floor, you must insulate yourself from both the ground and the victim:
  7. Step A (Insulate your feet): Stand on a thick, completely dry, non-conductive material such as a rubber doormat, a pair of dry rubber-soled work boots, a dry wooden cutting board, or a thick stack of dry books or folded dry towels.
  8. Step B (Select a dry non-conductive tool): Grab a long object made of pure insulator material: a dry wooden broom handle, a dry wooden chair, a solid plastic or PVC pipe, a fiberglass tool handle, or a dry rolled-up cotton blanket or dry nylon rope looped around the victim's dry limb or clothing.
  9. Step C (Verify zero metal or moisture): Ensure the broom handle does not have a metal hanging cap, wet paint, or moisture on it, and never grab the victim's bare skin or damp, sweaty clothing.
  10. Step D (Break contact in one decisive stroke): Use the wooden pole to shove the victim's hand off the wire, or knock the appliance cord away from the victim, in a single firm push so they do not fall back onto the live conductor.

2. High-voltage emergencies, downed power lines, and step potential

When an overhead utility line (carrying 4,000 to 35,000+ volts) snaps during a storm or car crash and falls onto the ground, roadway, fence, or tree, two invisible physical hazards immediately form around the contact point: electrical arcing and ground step potential (voltage gradient).

Understanding step potential and touch potential

When a live high-voltage cable rests on the earth, it does not always trip the utility substation breaker, especially if the soil, dry asphalt, or tree branch offers moderate impedance. Instead, thousands of volts of electricity pour continuously into the ground and spread outward in concentric circular rings of decreasing voltage, exactly like ripples spreading outward when a rock is dropped into a pond:

-Directly touching the wire on the ground, the soil may be at 15,000 volts. - At 2 meters (6.5 feet) away, the soil may be at 10,000 volts. - At 4 meters (13 feet) away, the soil may be at 6,000 volts. - At 10 meters (33 feet) away, the soil drops toward 0 volts.

If a rescuer runs or walks with a normal 0.8-meter (2.5-foot) stride into this concentric zone, their front foot plants on the 8,000-volt ring while their back foot rests on the 10,000-volt ring. That 2,000-volt difference between their two feet (step potential) instantly chooses the low-resistance human body over the high-resistance dirt: current shoots up one leg, through the pelvic organs and heart, and down the other leg, causing immediate tetanic collapse onto the ground, where the horizontal body now spans an even wider voltage gap (bridge potential), proving rapidly fatal.

Similarly, touch potential occurs when a person stands on the ground and touches a metal chain-link fence, metal guardrail, or vehicle body that is touching a downed power line hundreds of meters down the street.

How to escape a downed power line zone (Shuffle or Bunny-Hop)

If you suddenly realize you are standing within 10 to 20 meters (33 to 65 feet) of a downed power line, or if you feel a tingling sensation in your legs and feet:

  1. Freeze your stride immediately: Do not take another walking step, and never run.
  2. Use the Two-Foot Shuffle method:
  3. Press your ankles and the inner edges of both shoes tightly together so your feet touch side-by-side.
  4. Slowly shuffle backward or away from the downed wire by sliding one foot forward only a few centimeters along the ground so the heel of your leading foot never passes the toes of your trailing foot, keeping both soles in continuous contact with the same voltage ring.
  5. Or use the Two-Foot Bunny-Hop method:
  6. Press your knees, ankles, and feet tightly together, cross your arms firmly against your chest so you do not lose balance and touch the ground with your hands, and hop away with both feet leaving and landing on the ground at the exact same instant.
  7. Never hop on one foot (if you fall over, your outstretched body will span multiple voltage rings).
  8. Continue shuffling or hopping until you are at least 10 meters (33 feet) away on dry ground, or 20 meters (65 feet) away if the pavement or grass is wet.

3. Trapped inside a vehicle touching a downed power line

If a utility pole falls across your car or truck:

  1. Stay inside the vehicle: As long as the car is not on fire, the safest place is sitting calmly inside the cabin. The metal body of the car acts as a Faraday cage while the rubber tires provide partial insulation, routing electricity around the exterior skin. Do not touch the metal door frames, window cranks, or radio, and call 911, 112, or 999 on your mobile phone. Warn bystanders loudly through a cracked window to stay at least 15 meters (50 feet) back.
  2. Emergency jump-and-shuffle evacuation (ONLY if the vehicle catches fire):
  3. If smoke or flames break out in the engine bay or cabin, you must exit without ever touching the metal car and the ground at the same time (which would turn your body into a direct ground bridge):
  4. Open the car door wide, being careful not to touch the exterior painted metal panel.
  5. Stand up on the interior floorboard or plastic door sill, cross your arms tightly over your chest, and tuck your chin.
  6. Jump clear of the vehicle so that both feet leave the car before either foot touches the ground, and land with both feet pressed tightly together.
  7. Kobɛta libaku te nsima mpe kosimba motuka na lobɔkɔ na yo. Mbala moko shuffle to bunny-hop na makolo nyonso mibale esika moko na boumeli ya ata 15 mètres (50 feet) yambo ya kotambola normalement.

Lisalisi ya liboso ya monganga na litambe na litambe ntango moto oyo azwi mpasi azali polele

Soki courant ekangami to moto oyo azwi mpasi akabwani malamu na conducteur, traumatisme électrique esengaka approche structurée C-A-B-C-D-E traumatisme réanimation mpo choc électrique esalaka en même temps arrêt cardiaque, paralysie respiratoire centrale, fractures ya mokuwa ya mokɔngɔ, mpe kozika na molunge.

Etape 1: Tala ndenge ya koyanola, kopema, mpe kobanda CPR / AED

  1. Beta mapeka ya moto oyo azwi mpasi mpe ganga mpo na kotala soki azali koyanola ntango ozali kosala scanner na ntolo mpo na kopema malamu na boumeli ya segɔnde koleka 10 te.
  2. Po na nini CPR ya molayi ezali na ntina mingi na choc électrique mpe na nkake:
  3. Na bokeseni na mibange oyo bazwaki mpasi na ba blocages ya ba artéries coronaires, mbala mingi baye bazwaki choc électrique to nkake bazalaka bilenge oyo bazali na mitema ya nzoto kolɔngɔnɔ oyo système ya conduction cardiaque na bango ekɔtisamaki mpo na mwa ntango moke na fibrillation ventriculaire (euti na AC) to asystole (euti na DC/foudre), to oyo centre respiratoire ya tronc cerveau na bango ekangamaki na apnée prolongée (arrêt respiratoire).
  4. Soki motema ya victime électrique ezali kokoba kobeta (to ebandi lisusu noki) kasi centre ya respiration ya tronche ya cerveau na bango etikali étonnant, bakokufa na arrêt cardiaque secondaire hypoxique na ba minutes longola se soki mutu apesi bango pema ya kobikisa mpe ba compressions ya ntolo.
  5. Triage inverse na ba nkake ya ba victimes ebele to na ba frappes ya haute tension: Normalement, na ba catastrophes ya ba victimes ya masse, ba sauveurs basalaka liboso ba victimes oyo ba pema mpe balekaka likolo ya ba victimes apnéiques/pulses sans pulsation. Na nkake to na ba frappes électriques, mobeko ezongisamaka sima ("Kosekwisa bakufi"): ba victimes oyo bazali kolela mpe koningana bazali na motema oyo ezali kobeta mpe bakobika mbala mosusu, nzokande victime oyo azali koningana te, ya bleu na mabele azali na fibrillation ventriculaire reversible to arrêt respiratoire ya tronche cerveau mpe akoki kobikisama na mbala moko CPR mpe défibrillation ya AED.
  6. Kopesa CPR ya qualité ya likolo (30 compressions na 2 pema ya kobikisa):
  7. Pusa makasi mpe mbangu na katikati ya ntolo na 100 kino 120 compressions na miniti na bozindo ya 5 kino 6 centimètres (2,0 kino 2,4 pouces) na mikóló.
  8. Lokola paralysie respiratoire ezali elembo ya tétanie thoracique mpe stunning ya tronche cerveau, kotia 2 pema ya kobikisa sima ya 30 compressions nionso soki ozali na makoki, kosalela manœuvre ya mbanga soki ba suspecter que okweyi to ozoki na mokuwa ya mokɔngɔ.
  9. Bokanga Desfibrillateur extérieur automatique (AED) noki soki ekomi. Sala ete ntolo ya moto oyo azwi mpasi epangusa mai to motoki, mpe tia ba tampons ata na ntaka ya santimetele 2,5 (1 pouce) mosika na kozika nyonso ya bokoti oyo eziki soki likoki ezali mpo ete char ya loposo epekisa te bopesi ya choc.

Etape 2: Ko immobiliser mokuwa ya mokɔngɔ ya cervix mpe kotala soki ezali na ba traumatismes blunt

Kobalusa ata moke te to kobwaka moto oyo azwi choc électrique semba kozanga kotalela mokuwa na ye ya mokɔngɔ:

  • Ba chocs ya tension makasi mpe ba jolts ya DC esalaka que ba muscles paraspinal ya makasi ekangama na mobulu, na mbala moko, oyo ekoki kosala fractures ya compression ya ba vertèbres thoraciques na lombaire to ba dislocations ya lipeka ya sima ata soki victime akweyaki jamais.
  • Lisusu, bato oyo basalaka kura, bato oyo basalaka toit, mpe bankolo bandako bazwaka mbala mingi kura ntango batɛlɛmi na eskalye, na ba échafaudages to na makonzí ya biloko oyo basalelaka.
  • Bomba ete moto oyo azwi mpasi alali na mokɔngɔ, tyá motó mpe nkingo na ye na mabɔkɔ na esika oyo ezali na molɔngɔ te na mabɔkɔ nyonso mibale soki akweyaki to abwakami, mpe talá soki ezali na misisa ya makila oyo ekoki koboma ye kobima makila. Soki moto oyo azwi mpasi azali koyeba eloko te, azali kopema malamu, mpe abandi kosanza, roll-roll nzoto na ye mobimba na mopanzi na bango lokola unité moko ya rigide wana ozali kobatela motó, nkingo mpe nzoto na ye na molɔngɔ.

Etape 3: Salisa ba brûles ya entrée, sortie, na arc ya courant

Kozika ya kura ezalaka na mitindo misato ekeseni: kozika ya solosolo ya contact (bampota ya bokɔti mpe ya kobima epai courant ekɔtaki na loposo mpe ebimaki na mabele), kozika ya flash ya arc (ezwamaka na molunge ya plasma oyo ezali kongɛnga kino na 19.000 °C / 35.000 °F ntango ba arcs ya tension makasi na mopɛpɛ kozanga ete ekɔta na nzoto), mpe flame thermique secondaire kozika (ntango ba étincelles epelisaka chemise to pantalon ya victime).

  1. Luka bampota ya bokoti MPE ya kobima: Ntango nyonso oyo omoni kozika ya miso ya ngɔmbɛ oyo esili kozika, oyo elɛmbi, oyo ezali na mposo ya nyama, to oyo ezali mpɛmbɛ na lobɔkɔ to misapi ya moto oyo azwi mpasi, talá ntango nyonso na soles ya makolo na ye, ya misapi ya makolo, ya lobɔkɔ oyo ekeseni, ya makolo, mpe loposo ya motó mpo na mpota ya kobima oyo ekokani na yango, oyo mbala mingi emonanaka lokola ete epanzanaki libanda.
  2. Kosala malili ya kozika ya libanda na mayi ya malili oyo ezali koleka na boumeli ya miniti 20: Soki moto oyo azwi mpasi azali mpenza mosika na ba sources nionso ya kura mpe azali kopema na ndenge ya stable, kosukola na malembe kozika ya molunge mpe ya contact na mayi ya malili ya robinet oyo ezali koleka (pene na 15 °C / 59 °F) na boumeli ya miniti 20. Kozongisa nsima CPR te mpo na kopelisa bisika oyo eziki, mpe kotika malili soki mobɛli abandi koningana (hypothermie).
  3. Longola bijoux mpe ba montres oyo ezali kokangama mbala moko: Courant électrique ya mozindo esalaka kovimba monene, ya mbangu ya mayi (œdème) na loboko to makolo mobimba na boumeli ya miniti. Glissé ba rings nionso, ba bracelets, ba montres, na ba bottes ya seresere mbala moko liboso kovimba ekanga yango mpe ekata makila.
  4. Kopakola ata moke te glace, manteka, mafuta, to ba enveloppes circonférences serrées: Zipa ba mpota ya bokoti mpe ya kobima oyo esili malili na bokasi na gaze stérile oyo ekangami te to na lokasa ya peto ya film ya plastique ya ndako oyo ekangamaka na bolai likolo ya enama (kozinga yango ata moke te makasi zingazinga ya enama lokola tourniquet).

Etape 4: Kosalisa mpo na choc hypovolémique

Kozika ya mozindo ya kati ya kura ebendaka ba volumes minene ya mayi ya plasma libanda ya makila na ba compartiments muscles oyo ebebi, e déclenchaka choc hypovolémique ya mbangu:

  • Bomba mobɛli oyo azali na makanisi, oyo azali kopema alali mpe zipa bango na elamba ya pɛpɛlɛ mpo na kobatela molunge ya nzoto ya moboko.
  • Kopesa moto oyo azwi mpasi eloko ya kolya to komɛla te (mai, kafe, to bankisi ya mpasi te), mpo ete mbala mingi bato ya maladi oyo bazoki na kura ya moke to ya makasi basengeli na anesthésie générale ya nokinoki na salle d’opération mpo na kolongolama ya kozika na lipaso to fasciotomie na boumeli ya bangonga nsima ya kokóma.

"Effet iceberg" : pourquoi choc électrique nionso esengaka évaluation ya lopitalo

Likama moko ya monene ya monganga nsima ya kobika na mpasi ya ebandeli ezali effet glace: kozika ya loposo oyo emonanaka na likoló ezali komonisa na nse ya 5 kino 10 % ya kobebisama mobimba ya misisa oyo ebombami na kati ya nzoto.

    THE ELECTRICAL INJURY "ICEBERG EFFECT"

        [ Tiny Pinpoint Skin Entrance Burn ]   <-- Visible Surface (5%)
    ============================================   Skin Line
       /                                    \
      /   1. Bone heats to extreme temps     \
     /    2. Deep periosteal muscle cooks     \ <-- Hidden Internal
    /     3. Swelling inside rigid fascia      \    Destruction (95%)
   /         causes Compartment Syndrome        \
  /       4. Dead muscle releases Myoglobin      \
 /           causing Acute Kidney Failure         \
+--------------------------------------------------+

1. Nécrose ya misisa ya mozindo pembeni ya mokuwa ("Kolamba na kati-na libanda") .

Mpo na nini mosali ya kura akoki kozala kaka na libumu ya milimɛtrɛ 5 (0,2 pouces) na lobɔkɔ na ye mpe atako bongo abungisa liboso lobɔkɔ na ye mobimba nsima ya ngonga 48?

  • Na kati ya loboko to makolo, mokuwa compact ezali na résistance électrique ya likolo koleka tissus nionso ya moto (pene na 900 ohms-cm, soki tokokanisi yango na 70 ohms-cm mpo na makila mpe misisa mpe 150 ohms-cm mpo na misisa).
  • Na mobeko ya Joule (\(Q = I^2 R t\)), lokola courant électrique ezali komata na loboko, mokuwa ya katikati esalaka lokola eloko oyo epelisaka molunge na kati ya toast, epelisaka molunge na molunge makasi mpe kolamba misisa ya mikuwa ya mozindo oyo ekangami mbala moko na mokuwa uta na kati libanda.
  • Loposo oyo ezali likoló, oyo mopɛpɛ ya shambre ekómisaka malili, ekoki komonana mpenza langi ya rozɛ mpe ebebi te nzokande eteni ya mozindo ya flexeur oyo ezali na nse na yango ezali coagulé mpe nécrotique.

2. Syndrome ya compartiment aigu (Urgence ya lipaso) .

Misisa ya mikuwa na liboso ya maboko mpe na nse ya makolo ekangami na kati ya manzaka ya makasi, ya fibreuse oyo ekangamaka te oyo babengaka fascia.

  • Lokola misisa oyo eziki na kura na mozindo ezali kovimba na mai ya œdème, pression oyo ezali na kati ya manche fascial oyo ekangami emati na lola koleka 30 mmHg, konyataka ba artéries mpe ba nerfs oyo ezali koleka na enama (syndrome ya compartiment aigu).
  • Bilembo ya likebisi (The 6 Ps): Excruciating profond Pasi hors proportion na petite loposo kozika (surtout pasi ya somo tango misapi to misapi ya makolo etandami passivement), Paresthésie (énergie ya pins-and-needles na misapi/misapi ya makolo), Pallor (chiffres pâles ou mottled), Paralyse (bolembu oyo ezali koningana na loboko/makolo), Poikilothermie (limbe eyokaka malili), mpe Kozanga pulse (elembo ya retard).
  • Soki mobɛli azali na lopitalo te epai wapi minganga ya lipaso ya traumatisme bakoki kosala mbala moko fasciotomie décompressive (kosala ba incisions milayi ya lipaso mpo na kobimisa pression), loboko mobimba, loboko to makolo ekoki kokufa na boumeli ya ngonga 4 kino 6.

3. Rhabdomyolyse (Myoglobinuria) mpe insuffisance aiguë ya rein

Ntango courant électrique epanzani bamilio ya baselile ya misisa ya mikuwa, biloko mibale ya ngɛngɛ oyo ezali na kati ya baselile ekɔtaka na makila:

  • Potassium (Hypercalémie): Bobimisi ya potassium mingi na ba cellules ya muscle oyo ekufa ematisaka niveau ya potassium na makila, oyo ekoki ko déclencher lethal arrêt cardiaque secondaire heures après choc ya liboso.
  • Myoglobine (Rhabdomyolyse): Myoglobine ezali proteine ​​ya kilo oyo ezali na fer oyo ekangisaka oxygène na kati ya ba fibres musculaires. Ntango ebwakami na makila, myoglobine e filtraka na kati ya ba reins mpe e précipiter lokola ba casts ya minene, ya molili ya bosoto oyo ekangaka ba tubules rénaux microscopiques, esalaka insuffisance rénale aigu (nécrose tubulaire aiguë).
  • Elembo ya likebisi ya makila ya langi ya ti to ya cola: Soki moto nyonso oyo azwaki choc électrique aleki makila oyo ezali komonana rose, rouge, motane-marron, langi ya ti ya moindo, to ya langi ya cola ya moindo, azali na rabdomyolyse makasi mpe asengeli kozongisama mbala moko na mbala moko fluide intraveineuse na unité ya kozika/traumatisme.

4. Kozika na commissure orale pédiatrique (Koswa nsinga ya kura).

Bana mike batafunaka ntango mosusu bansinga ya kobakisela oyo ezali na bomoi to ba fiches ya chargeur, mpe yango esalaka ete arc électrique ezala na coin ya monoko. Esengeli kotalela mwana nyonso oyo azali na kozika na kura na monɔkɔ na lopitalo. Penepene na mikolo 5 kino 14 nsima ya kozoka, nsuki ya mpɛmbɛ oyo ekufá elongwaka mpe ekoki kokɔta na artérie labial, mpe kosala ete makila ebima na mbalakaka na mbɛbu ya misisa. Soki makila ebandi kobima mikolo nsima, finá mbɛbu makasi kati na mosapi monene (na kati ya monɔkɔ) mpe mosapi ya index (na libándá ya mbɛbu) na lisalisi ya gaze ya pɛto mpe kende mbala moko na salle d’urgence.

Critères obligatoires pona évaluation ya département d’urgence na suivi ya ECG

Moto nyonso oyo azwi choc électrique ya solosolo na ba câbles ya réseau, bisaleli, to nkake asengeli kotalelama na monganga. Transport ya mbala moko ya Département d’urgence mpe suivi électrocardiogramme (ECG) à 12 plomb ezali obligatoire soki moko ya makambo oyo elandi ezali:

  • Kokutana na tension ya likolo (>1,000 V) to ** nkake**, to kobungisa makanisi nyonso, mobulungano, to amnésie.
  • Nzela nyonso ya transthoracique (loboko na loboko to loboko na makolo) to "no-let-go" lock tétanique oyo eumelaki mingi na nsinga ya ndako.
  • Pasi ya ntolo, motema kobɛtabɛta, kopema mokuse, komonana kozika ya kokɔta to kobima, mpasi ya misisa ya mozindo, to makila ya langi ya tii ya moindo.
  • Zemi na étape nionso (esengaka suivi ya fœtus mbala moko) to ba conditions cardiaques préexistantes.

Tip

Tala kosala cours ya maboko ya CPR, AED, mpe certification ya secours ya liboso na Croix-Rouge, Ambulance St John, to Association américaine ya motema. Koyeba kosala ba compressions ya ntolo mpe kosala AED mbala moko nsima ya kobuka contact électrique ebakisaka mbala mibale libaku ya moto oyo azwi mpasi ya kobika.

Mituna oyo batunaka mingi

Choc électrique ekoki kosala crise cardiaque to arrêt cardiaque na retard bangonga sima soki nazali koyoka malamu mobimba sikoyo?

Soki okutanaki na choc ya tension makasi (koleka 1.000 volts), obungisaki makanisi ata mpo na mwa ntango moke, ozali na mpasi ya mozindo ya misisa to kozika, to oyoki mpasi nyonso na ntolo to kobɛtabɛta ya motema oyo ezali kopumbwapumbwa, ba arrhythmies cardiaques oyo eumelaka ekoki kobima bangonga nsima mpo na kozoka ya myocarde to kotanga ya potassium na baselile ya misisa oyo ebebi, oyo esɛngaka lopitalo ya ngonga 24 Surveillance ya ECG. Mpo na mwa ntango mokuse ya choc ya ndako ya tension moke (120 V kino 240 V) epai wapi obungisaki makanisi ata moke te mpe ozali koyoka malamu, vérification médicale ya noki na électrocardiogramme normal ya 12 plomb (ECG) elongolaka likama ya rythme cardiaque oyo ezongisaka retard.

Mpo na nini Courant Alternatif (AC) ya ndako ezali likama mingi koleka Courant Direct (DC) na tension moko?

Courant alternatif ya ndako ebalukaka liboso mpe sima na 50 to 60 cycles par seconde (50/60 Hz), oyo e stimulaka ba fibres ya muscle squelettique ya moto na spasme tétanique continue, bloqué (phénomène "no-let-go"). Lokola misisa ya flexeur ya liboso ya loboko ezali makasi koleka misisa ya extenseur, loboko ya moto oyo azwi mpasi ekangamaka makasi zingazinga ya nsinga ya bomoi, mpe yango ebakisaka mpenza ntango oyo courant ezali koleka mpe kolamba ya kati ya misisa. En plus, 50/60 Hz AC ebetaka mbala na mbala fenêtre ya repolarisation vulnérable ya motema, e déclenchaka fibrillation ventriculaire na courant mbala misato to mitano ya se koleka DC.

Ezali malamu kosalela balabala ya mabaya to etape ya nzete oyo ekauki mpo na kotindika nsinga ya kura oyo ekwei likoló na moto?

Te, komeka ata moke te kosalela balabala ya mabaya, etape ya nzete, pipe ya plastiki, to ba gants ya caoutchouc mpo na kotambolisa nsinga ya kura oyo ezali likoló to nsinga nyonso ya tension makasi (>1.000 volts). Bisaleli ya ndako oyo etambwisaka te ekangamaka kaka na courant ya ndako ya tension moke (110 V kino 240 V). Na ba tensions ya distribution ya 4.000 à 35.000 volts, courant e arc sans effort na mopepe mpe etambolaka na ba nzela ya humidité microscopique mpe ya résine na mabaya to na plastique mbala moko na kati ya mobikisi, mpe ebomaka bato nyonso mibale. Tikala ntango nyonso na ntaka ya mɛtrɛ 10 kino 20 mpe zela ete kompanyi oyo esalaka kura elongola nguya na nsinga.

Mpo na nini nasengeli kosala ba shuffle to kopumbwa na makolo nyonso mibale esika moko pene na nsinga ya kura oyo ekwei ata soki nazali kosimba nsinga te?

Ntango nsinga ya bomoi oyo ezali na tension makasi esimbaki mabele, kura ekɔtaka na libándá na mabele na ba rings concentriques oyo tension ezali kokita, lokola ba ondulations oyo ezali na etima. Soki ozali kotambola malamu, makolo na yo ya liboso ekiti na lopɛtɛ oyo ezali na tension moko nzokande makolo na yo ya nsima esimbaka lopɛtɛ oyo ezali na tension mosusu. Bokeseni wana ya tension kati na makolo na yo (potentiel ya pas) etindaka courant ya amperage makasi emata likolo ya makolo moko, na nzela ya pelvis mpe motema na yo, mpe ekita na makolo mosusu. Kobatela makolo nyonso mibale efinamaki makasi esika moko mpe kosala mélange to kopumbwa esalaka ete makolo nyonso mibale ezala na potentiel électrique ndenge moko mpenza mpo ete circuit moko te esalema na nzoto na yo.

Why does an electrical shock victim need to go to the emergency room if their skin only has a tiny pinpoint burn?

Ba blessures ya courant elandi "effet iceberg," esika 95% ya ba dégâts esalemaka libanda ya komonana na mozindo ya nzoto. Lokola mokuwa ezali na résistance électrique mingi koleka ba tissus nionso, courant oyo ezali koleka na loboko to na makolo epelisaka mokuwa na molunge makasi, kolamba ba couches ya misisa ya mozindo oyo ezingami zingazinga ya mokuwa wana etikaka loposo ya libanda emonanaka pene na normal. Kobebisama wana ya mozindo ya misisa ekoki nokinoki kobimisa syndrome ya compartiment menacer ya maboko mpe maboko mpe kobimisa ba protéines ya misisa (myoglobine) oyo esalaka ete rein esala insuffisance aiguë na boumeli ya bangonga.

What should a pregnant woman do if she receives a minor household electric shock?

Moto nyonso ya zemi oyo azwi choc courant na prise ya ndako, aparɛyi, to nsinga oyo ezali na mbeba, mingimingi soki courant ekɔtaki na lobɔkɔ mpe ekɔti na mabele na makolo, asengeli kokende mbala moko na departema ya lisalisi ya nokinoki to na unité ya triage obstétrique, ata soki ayoki ete azoki ata moke te mpe loposo eziki te. Liquide amniotique mpe circulation ya mwana oyo azali na libumu epesaka résistance électrique moke mpenza, elingi koloba mwa courant oyo ezali kolɛnga na mpasi lobɔkɔ ya mama ekoki koleka mbala moko na matrice mpe kosala bopusi likoló na rythme cardiaque to placenta ya mwana.

Ba guides oyo etali yango

Ba sources e vérifié

  • Association américaine du cœur (AHA, Etats-Unis) mpe Comité international de liaison sur le réanimation (ILCOR): Mabongisi mpo na bozongisi motema mpe mimpululu mpe soins ya urgence cardiovasculaire (Circonstances spéciaux ya réanimation: Kozoka na kura mpe nkake)
  • Conseil européen de réanimation (ERC): Mabongisi mpo na arrêt cardiaque na ba circonstances spéciales , électrocution mpe frappe ya nkake
  • Occupational Safety and Health Administration (OSHA, United States) and National Institute for Occupational Safety and Health (NIOSH / CDC, United States): Electrical Safety, Step Potential, and Arc Flash Trauma Directives
  • American Burn Association (ABA, United States): Advanced Burn Life Support (ABLS) Clinical Practice Guidelines for Electrical and Lightning Injuries
  • National Health Service (NHS, United Kingdom) and St John Ambulance (United Kingdom): First Aid Protocols for High-Voltage and Low-Voltage Electric Shock