Electric shock first aid: what to do and what to avoid

Manambala angozi amasiyana malinga ndi dziko. Tsambali limagwiritsa ntchito 911, nambala ya United States ndi Canada. Mayiko ena ambiri amagwiritsa ntchito 112, 999, kapena nambala ina. Pezani nambala ya dziko lanu.

Electrical injuries are among the most deceptive and complex emergencies in trauma medicine. While the visible skin contact points may appear as minor, pinpoint surface burns, electrical current passing through the human body converts into intense internal thermal energy along deep anatomical pathways. Within milliseconds, household or industrial current can induce involuntary muscle paralysis that locks the victim onto the live conductor, trigger lethal ventricular fibrillation or respiratory arrest, coagulate deep vascular networks, cook periosteal skeletal muscle against heated bone, and fracture the spine through violent tetanic contractions.

The absolute first rule of any electrical emergency is rescuer safety: touching a person who remains in contact with an energized electrical source turns you into an immediate secondary casualty. Knowing how to isolate household and commercial power, separate a low-voltage victim using dry non-conductive insulators, escape the concentric ground-voltage rings (step potential) of a downed high-voltage utility line, initiate immediate cardiopulmonary resuscitation (CPR), and recognize delayed internal complications such as rhabdomyolysis and compartment syndrome saves lives.

Chitani izi tsopano

  1. Do not touch the victim with your bare hands, clothing, or any metal or wet object while they are still touching the electrical source. The human body is an electrolytic conductor; grabbing an electrified person transfers the live current directly through your own heart and nervous system.
  2. Call emergency services immediately and state that an electrical injury has occurred. Call your local emergency number (911 in the United States and Canada, 112 across the European Union, 999 in the United Kingdom) or check manambala angozi, and request both paramedics and the electric utility company if high-voltage lines are involved.
  3. Shut off the electrical power source immediately if it is low-voltage household or commercial power (under 1,000 volts). Flip the main circuit breaker switch at the electrical service panel, unscrew the fuse, switch off the wall socket switch (where equipped), or pull the insulated rubber plug from the outlet if the cord is undamaged and away from water.
  4. Stay at least 10 to 20 meters (33 to 65 feet) back if the source is high-voltage (over 1,000 volts), a downed overhead power line, or lightning. Never attempt to pry a high-voltage wire off someone with a broomstick or wooden branch, because high-voltage electricity arcs through the air and travels down non-conductive poles; wait until utility technicians confirm the grid is de-energized and grounded.
  5. If low-voltage household power cannot be switched off immediately, push the victim or wire away using a completely dry, non-conductive object. Stand on a dry insulating surface (such as a rubber doormat, dry wooden board, or thick stack of newspapers) and use a dry wooden broom handle, fiberglass pole, dry PVC pipe, or looped dry cotton rope to break contact.
  6. Check responsiveness and breathing the instant the victim is clear of the electricity, and start CPR immediately if needed. If the person is unresponsive and not breathing normally (or only taking irregular agonal gasps), begin cardiopulmonary resuscitation (CPR) at 100 to 120 compressions per minute and attach an Automated External Defibrillator (AED) as soon as one arrives; if they are breathing, cool any visible burns with cool running water for 20 minutes and keep their neck and spine still.
flowchart TD
    Start["Person in Contact with Electrical Source"] --> HVCheck{"Is it High Voltage (>1,000 V), a downed power line, or wet environment?"}
    HVCheck -->|"Yes: High Voltage or Downed Line"| HVProtocol["Keep 10 to 20 meters (33 to 65 feet) away; NEVER approach or use poles"]
    HVProtocol --> CallUtil["Call 911 / 112 / 999 and electric utility; shuffle with feet together if inside zone"]
    HVCheck -->|"No: Low Voltage Household (110 V to 240 V)"| CutPower{"Can you safely shut off the breaker or unplug the cord?"}
    CutPower -->|"Inde"| PowerOff["Flip main circuit breaker to Off or pull insulated plug"]
    CutPower -->|"Ayi"| Insulate["Stand on dry rubber or wood; push wire or victim away with dry wood or plastic tool"]
    PowerOff --> Assess["Victim Free of Current: Check responsiveness and breathing for 10 seconds"]
    Insulate --> Assess
    Assess --> BreathCheck{"Is the victim responsive and breathing normally?"}
    BreathCheck -->|"No (Unresponsive / Agonal gasps)"| StartCPR["Start CPR (30:2 or Hands-Only) at 100 to 120 bpm and apply AED immediately"]
    BreathCheck -->|"Yes (Breathing normally)"| TraumaCare["Immobilize spine if fallen, cool burns with cool running water for 20 min, transport to ER"]

Physics and pathophysiology of electrical trauma

When an electrical circuit forms across the human body, the severity of cellular and organ destruction is governed by six physical variables summarized by Ohm's Law (\(I = V / R\), where current equals voltage divided by resistance) and Joule's First Law of Heating (\(Q = I^2 \times R \times t\), where thermal heat generated equals the square of the current multiplied by tissue resistance and contact duration):

  1. Amperage (Current intensity in milliamperes, mA): Amperage is the primary physiological killer, determined by the driving voltage divided by skin and internal tissue resistance.
  2. Voltage (Electrical potential in volts, V): Divided clinically into low voltage (under 1,000 volts, such as 120 V North American mains, 230 V European/UK/Australian mains, and 400 V three-phase commercial wiring) and high voltage (1,000 volts and above, such as overhead utility distribution lines carrying 4,160 V to 34,500 V and transmission towers carrying 115,000 V to 765,000 V).
  3. Resistance (Impedance in ohms, \(\Omega\)): Dry, calloused human palms offer high resistance (up to 40,000 to 100,000 ohms), which limits current flow. However, wet skin, sweaty skin, immersed skin in a bathtub, or broken skin drops epidermal resistance down to 500 to 1,000 ohms. At 1,000 ohms of wet skin resistance, touching a standard 120-volt or 230-volt bathroom appliance delivers 120 to 230 milliamperes directly into the bloodstream, which is more than enough to trigger instant cardiac arrest.
  4. Type of current: Alternating Current (AC) versus Direct Current (DC).
  5. Anatomical pathway (Transthoracic vs vertical): Current travels along the path of least electrical resistance (blood vessels, nerves, and muscles) from the entrance contact point to the ground exit point:
  6. Hand-to-hand (horizontal transthoracic pathway): Current enters one hand, crosses directly through the mediastinum and heart, and exits the opposite hand. This pathway carries the highest mortality rate (~60 percent in high-voltage contacts) due to direct myocardial fibrillation.
  7. Hand-to-foot (vertical pathway): Current travels from the upper extremity through the thorax, abdominal organs, and leg to the floor.
  8. Foot-to-foot (stride or step potential pathway): Current enters one foot, crosses the pelvis, and exits the other foot.
  9. Duration of contact (\(t\)): The longer the body stays connected to the wire, the more thermal heat accumulates inside deep tissues and the skin breaks down, dropping resistance further and accelerating current inflow.

Physiological effects of 50/60 Hz AC current by milliamperes

Current Intensity (mA, 1-second contact) Physiological Effect on the Human Body Clinical Outcome
1 to 3 mA Threshold of sensory perception Mild tingling sensation at the fingertips; no tissue damage
5 to 10 mA Painful sensory shock Sharp pain; normal adult can still voluntarily release their grip ("let-go" current)
10 to 20 mA The "Let-Go" Threshold (Flexor Tetany) Involuntary tetanic contraction of forearm flexor muscles locks the hand tightly around the wire; victim cannot let go
20 to 50 mA Thoracic and Diaphragmatic Tetany Continuous paralysis of the diaphragm and intercostal breathing muscles; causes respiratory arrest and asphyxiation if contact continues
50 to 100 mA Ventricular Fibrillation (V-Fib) Threshold Electrical current strikes during the vulnerable cardiac T-wave repolarization window, throwing the heart into chaotic fibrillation
1,000 to 4,000 mA (1 to 4 Amps) Sustained Myocardial Contraction (Asystole) and Deep Thermal Burns Complete clamping standstill of the heart muscle combined with massive deep internal tissue cooking

Alternating Current (AC) versus Direct Current (DC)

Clinical and Physical Feature Alternating Current (AC: 50 Hz / 60 Hz) Direct Current (DC)
Common Real-World Sources Household wall outlets (120 V / 230 V), kitchen appliances, power tools, commercial HVAC, overhead utility lines Automotive and EV battery packs (12 V to 800 V), solar photovoltaic arrays, electrified subway third rails, arc welders, lightning
Skeletal Muscle Response Continuous tetanic spasm ("No-Let-Go" phenomenon): Because current reverses direction 50 to 60 times per second, forearm flexor muscles contract continuously, clamping the victim's fist onto the live wire Single violent ballistic contraction: Produces a single massive muscle spasm that frequently throws the victim several meters backward away from the power source
Primary Cardiac Arrhythmia Ventricular Fibrillation (V-Fib): 3 to 5 times more dangerous than DC at low voltages because the 50/60 Hz cycle repeatedly crosses the vulnerable cardiac repolarization phase Ventricular Asystole (Cardiac Standstill): High-voltage DC depolarizes the entire myocardium at once, stopping the heartbeat completely
Associated Trauma Profile Prolonged contact time leading to deep internal thermal necrosis, respiratory asphyxiation, and local full-thickness entrance/exit burns Shorter contact time, but high rates of blunt orthopedic trauma (skull fractures, cervical spine fractures, ruptured spleen, long-bone fractures) from being thrown or falling off ladders

Safe rescue protocols: breaking electrical contact

Danger

Never approach within 10 meters (33 feet) of a downed overhead power line, substation transformer, electrified train rail, or any high-voltage industrial source exceeding 1,000 volts, and never attempt to move a high-voltage wire with a wooden broom, tree branch, or plastic tool. High-voltage electricity ionizes the air to jump (arc) across open space and travels directly down the surface moisture of wood or plastic into your body.

1. Low-voltage household and workplace rescue (Under 1,000 Volts)

When someone is being shocked by a 120-volt or 230-volt household appliance, extension cord, power tool, or faulty switch:

  1. Cut the power at the source first (Always the safest method):
  2. Run to the household electrical distribution panel (fuse box or breaker box) and flip the Main Breaker to the Off position, or flip the specific branch circuit breaker.
  3. In the United Kingdom, Europe, and Australia, wall sockets feature an individual rocker switch; if the wall socket is dry and you can reach it without touching the victim or appliance, flip the socket switch off with a dry non-conductive object and pull the plug.
  4. If the victim is holding an appliance in a wet area (bathroom floor, flooded basement, swimming pool deck, or wet lawn), never step onto the wet floor or touch the appliance cord. Shut off power exclusively at the main house breaker panel while standing on dry flooring.
  5. How to separate a victim when the breaker is unreachable:
  6. If you cannot reach the circuit breaker within seconds and the victim is locked in tetanic spasm on a dry indoor floor, you must insulate yourself from both the ground and the victim:
  7. Step A (Insulate your feet): Stand on a thick, completely dry, non-conductive material such as a rubber doormat, a pair of dry rubber-soled work boots, a dry wooden cutting board, or a thick stack of dry books or folded dry towels.
  8. Step B (Select a dry non-conductive tool): Grab a long object made of pure insulator material: a dry wooden broom handle, a dry wooden chair, a solid plastic or PVC pipe, a fiberglass tool handle, or a dry rolled-up cotton blanket or dry nylon rope looped around the victim's dry limb or clothing.
  9. Step C (Verify zero metal or moisture): Ensure the broom handle does not have a metal hanging cap, wet paint, or moisture on it, and never grab the victim's bare skin or damp, sweaty clothing.
  10. Step D (Break contact in one decisive stroke): Use the wooden pole to shove the victim's hand off the wire, or knock the appliance cord away from the victim, in a single firm push so they do not fall back onto the live conductor.

2. High-voltage emergencies, downed power lines, and step potential

When an overhead utility line (carrying 4,000 to 35,000+ volts) snaps during a storm or car crash and falls onto the ground, roadway, fence, or tree, two invisible physical hazards immediately form around the contact point: electrical arcing and ground step potential (voltage gradient).

Understanding step potential and touch potential

When a live high-voltage cable rests on the earth, it does not always trip the utility substation breaker, especially if the soil, dry asphalt, or tree branch offers moderate impedance. Instead, thousands of volts of electricity pour continuously into the ground and spread outward in concentric circular rings of decreasing voltage, exactly like ripples spreading outward when a rock is dropped into a pond:

-Directly touching the wire on the ground, the soil may be at 15,000 volts. - At 2 meters (6.5 feet) away, the soil may be at 10,000 volts. - At 4 meters (13 feet) away, the soil may be at 6,000 volts. - At 10 meters (33 feet) away, the soil drops toward 0 volts.

If a rescuer runs or walks with a normal 0.8-meter (2.5-foot) stride into this concentric zone, their front foot plants on the 8,000-volt ring while their back foot rests on the 10,000-volt ring. That 2,000-volt difference between their two feet (step potential) instantly chooses the low-resistance human body over the high-resistance dirt: current shoots up one leg, through the pelvic organs and heart, and down the other leg, causing immediate tetanic collapse onto the ground, where the horizontal body now spans an even wider voltage gap (bridge potential), proving rapidly fatal.

Similarly, touch potential occurs when a person stands on the ground and touches a metal chain-link fence, metal guardrail, or vehicle body that is touching a downed power line hundreds of meters down the street.

How to escape a downed power line zone (Shuffle or Bunny-Hop)

If you suddenly realize you are standing within 10 to 20 meters (33 to 65 feet) of a downed power line, or if you feel a tingling sensation in your legs and feet:

  1. Freeze your stride immediately: Do not take another walking step, and never run.
  2. Use the Two-Foot Shuffle method:
  3. Press your ankles and the inner edges of both shoes tightly together so your feet touch side-by-side.
  4. Slowly shuffle backward or away from the downed wire by sliding one foot forward only a few centimeters along the ground so the heel of your leading foot never passes the toes of your trailing foot, keeping both soles in continuous contact with the same voltage ring.
  5. Or use the Two-Foot Bunny-Hop method:
  6. Press your knees, ankles, and feet tightly together, cross your arms firmly against your chest so you do not lose balance and touch the ground with your hands, and hop away with both feet leaving and landing on the ground at the exact same instant.
  7. Never hop on one foot (if you fall over, your outstretched body will span multiple voltage rings).
  8. Continue shuffling or hopping until you are at least 10 meters (33 feet) away on dry ground, or 20 meters (65 feet) away if the pavement or grass is wet.

3. Trapped inside a vehicle touching a downed power line

If a utility pole falls across your car or truck:

  1. Stay inside the vehicle: As long as the car is not on fire, the safest place is sitting calmly inside the cabin. The metal body of the car acts as a Faraday cage while the rubber tires provide partial insulation, routing electricity around the exterior skin. Do not touch the metal door frames, window cranks, or radio, and call 911, 112, or 999 on your mobile phone. Warn bystanders loudly through a cracked window to stay at least 15 meters (50 feet) back.
  2. Emergency jump-and-shuffle evacuation (ONLY if the vehicle catches fire):
  3. If smoke or flames break out in the engine bay or cabin, you must exit without ever touching the metal car and the ground at the same time (which would turn your body into a direct ground bridge):
  4. Open the car door wide, being careful not to touch the exterior painted metal panel.
  5. Stand up on the interior floorboard or plastic door sill, cross your arms tightly over your chest, and tuck your chin.
  6. Jump clear of the vehicle so that both feet leave the car before either foot touches the ground, and land with both feet pressed tightly together.
  7. Do not stumble backward and touch the car with your hand. Immediately shuffle or bunny-hop with both feet together for at least 15 meters (50 feet) before walking normally.

Step-by-step medical first aid once the victim is clear

Once the power is off or the victim has been safely separated from the conductor, electrical trauma requires a structured C-A-B-C-D-E trauma resuscitation approach because electrical shock simultaneously causes cardiac arrest, central respiratory paralysis, spinal fractures, and thermal burns.

Step 1: Assess responsiveness, breathing, and start CPR / AED

  1. Tap the victim's shoulders and shout to check responsiveness while scanning the chest for normal breathing for no more than 10 seconds.
  2. Why prolonged CPR is essential in electric shock and lightning:
  3. Unlike elderly victims of coronary artery blockages, victims of electric shock or lightning are often young with healthy hearts whose cardiac conduction system was momentarily scrambled into ventricular fibrillation (from AC) or asystole (from DC/lightning), or whose brainstem respiratory center was stunned into prolonged apnea (respiratory arrest).
  4. If an electrical victim's heart keeps beating (or restarts quickly) but their brainstem breathing center remains stunned, they will die of secondary hypoxic cardiac arrest within minutes unless someone gives them rescue breaths and chest compressions.
  5. Reverse triage in multi-casualty lightning or high-voltage strikes: Normally, in mass-casualty disasters, rescuers treat breathing victims first and pass over apneic/pulseless victims. In lightning or electrical strikes, the rule is reversed ("Resuscitate the dead"): victims who are groaning and moving have a beating heart and will likely survive, whereas the motionless, blue victim on the ground is in reversible ventricular fibrillation or brainstem respiratory arrest and can be saved with immediate CPR and AED defibrillation.
  6. Deliver high-quality CPR (30 compressions to 2 rescue breaths):
  7. Push hard and fast in the center of the chest at 100 to 120 compressions per minute to a depth of 5 to 6 centimeters (2.0 to 2.4 inches) in adults.
  8. Because respiratory paralysis is a hallmark of thoracic tetany and brainstem stunning, include 2 rescue breaths after every 30 compressions if you are able, using a jaw-thrust maneuver if a fall or spinal injury is suspected.
  9. Attach an Automated External Defibrillator (AED) as soon as it arrives. Ensure the victim's chest is wiped dry of water or sweat, and place the pads at least 2.5 centimeters (1 inch) away from any scorched entrance burn if possible so skin char does not impede shock delivery.

Step 2: Immobilize the cervical spine and check for blunt trauma

Never roll or yank an electrical shock victim upright without considering their spine:

  • High-voltage shocks and DC jolts cause violent, simultaneous contraction of the powerful paraspinal muscles, which can cause compression fractures of the thoracic and lumbar vertebrae or posterior shoulder dislocations even if the victim never fell.
  • Furthermore, electricians, roofers, and homeowners frequently suffer electric shocks while standing on ladders, scaffolding, or utility poles.
  • Keep the victim lying flat on their back, manually stabilize their head and neck in a neutral inline position with both hands if they fell or were thrown, and check for life-threatening arterial bleeding. If the victim is unconscious, breathing normally, and starts vomiting, log-roll their entire body onto their side as a single rigid unit while keeping the head, neck, and torso aligned.

Step 3: Treat electrical entrance, exit, and arc burns

Electrical burns come in three distinct forms: true contact burns (entrance and exit wounds where current entered the skin and exited to ground), arc flash burns (caused by radiant plasma heat up to 19,000 °C / 35,000 °F when high voltage arcs across the air without entering the body), and secondary thermal flame burns (when sparks ignite the victim's shirt or trousers).

  1. Search for both the entrance AND exit wounds: Whenever you find a charred, depressed, leathery, or pale bullseye burn on a victim's hand or fingers, always check the soles of their feet, toes, opposite hand, thighs, and scalp for the corresponding exit wound, which frequently looks exploded outward.
  2. Cool external burns with cool running water for 20 minutes: Once the victim is completely clear of all electrical sources and breathing stably, flush thermal and contact burns gently with cool running tap water (around 15 °C / 59 °F) for 20 minutes. Do not delay CPR to cool burns, and stop cooling if the patient begins shivering (hypothermia).
  3. Remove constricting jewelry and watches immediately: Deep electrical current causes massive, rapid fluid swelling (edema) along the entire arm or leg within minutes. Slide off all rings, bracelets, watches, and tight boots immediately before the swelling traps them and cuts off blood flow.
  4. Never apply ice, butter, ointments, or tight circumferential wraps: Cover the cooled entrance and exit wounds loosely with sterile non-adherent gauze or a clean sheet of household plastic cling film laid lengthways over the limb (never wrapped tightly around the limb like a tourniquet).

Step 4: Treat for hypovolemic shock

Deep internal electrical burns pull massive volumes of plasma fluid out of the bloodstream into damaged muscle compartments, triggering rapid hypovolemic shock:

  • Keep the conscious, breathing patient lying flat and cover them with a light blanket to conserve core body heat.
  • Do not give the victim anything to eat or drink (no water, coffee, or pain pills), because patients with moderate-to-severe electrical injuries often require emergency general anesthesia in the operating room for surgical burn debridement or fasciotomy within hours of arrival.

The "iceberg effect": why every electrical shock requires hospital evaluation

The single greatest medical danger after surviving the initial shock is the iceberg effect: visible surface skin burns represent less than 5 to 10 percent of the total tissue destruction hiding inside the body.

    THE ELECTRICAL INJURY "ICEBERG EFFECT"

        [ Tiny Pinpoint Skin Entrance Burn ]   <-- Visible Surface (5%)
    ============================================   Skin Line
       /                                    \
      /   1. Bone heats to extreme temps     \
     /    2. Deep periosteal muscle cooks     \ <-- Hidden Internal
    /     3. Swelling inside rigid fascia      \    Destruction (95%)
   /         causes Compartment Syndrome        \
  /       4. Dead muscle releases Myoglobin      \
 /           causing Acute Kidney Failure         \
+--------------------------------------------------+

1. Deep muscle necrosis along bone ("Inside-Out Cooking")

Why can an electrician have only a 5-millimeter (0.2-inch) blister on their palm and yet lose their entire forearm 48 hours later?

  • Inside an arm or leg, compact bone has the highest electrical resistance of any human tissue (roughly 900 ohms-cm, compared to 70 ohms-cm for blood and nerves and 150 ohms-cm for muscle).
  • By Joule's Law (\(Q = I^2 R t\)), as electrical current travels up the arm, the central bone acts like the heating element inside a toaster, heating to extreme temperatures and cooking the deep skeletal muscles attached directly to the bone from the inside out.
  • The overlying skin, cooled by room air, may look completely pink and unharmed while the deep flexor compartment beneath it is coagulated and necrotic.

2. Acute compartment syndrome (Surgical emergency)

Minofu ya m'mikono ndi m'miyendo yakumunsi imakutidwa mkati mwa manja olimba, osasunthika otchedwa fascia.

  • Pamene minofu yoyaka kwambiri yamagetsi imakula ndi edema yamadzimadzi, kupanikizika mkati mwa manja otsekedwa kumadutsa 30 mmHg, kuphwanya mitsempha ndi mitsempha yomwe imadutsa m'mbali (acute compartment syndrome).
  • Zizindikiro zochenjeza (The 6 Ps): Kupweteka kozama Kupweteka kosagwirizana ndi kawopsedwe kakang'ono kakhungu (makamaka kupweteka koopsa pamene zala kapena zala zala zala zimatambasulidwa), Paresthesia (mapini-ndi-singano dzanzi pa zala/zala), Pallor (kutupa) manambala otumbululuka,/kufooka kwa phazi* Poikilothermia (chiwalo chikumva kuzizira), ndi Pulselessness (chizindikiro chochedwa).
  • Ngati wodwalayo sali kuchipatala komwe madokotala ochita opaleshoni amatha kuchita mwamsanga ** decompressive fasciotomy ** (kupanga opaleshoni yaitali kuti athetse kupanikizika), dzanja lonse, mkono, kapena mwendo ukhoza kufa mkati mwa 4 kwa maola 6.

3. Rhabdomyolysis (Myoglobinuria) ndi kulephera kwa impso

Mphamvu yamagetsi ikaphulika mamiliyoni a maselo a minofu ya chigoba, zinthu ziwiri zapoizoni za intracellular zimasefukira m'magazi:

  • Potaziyamu (Hyperkalemia): Kutulutsidwa kwakukulu kwa potaziyamu m'maselo a minofu yakufa kumawonjezera kuchuluka kwa potaziyamu m'magazi, komwe kungayambitse kupha **kumangidwa kwamtima kwachiwiri pambuyo pa kugwedezeka koyamba **.
  • Myoglobin (Rhabdomyolysis): Myoglobin ndi puloteni yolemera yokhala ndi iron yomwe imamanga mpweya mkati mwa ulusi wa minofu. Ikaponyedwa m'magazi, myoglobin imasefa mu impso ndi kutsika ngati zokhuthala zakuda zomwe zimatsekereza ma tubules aimpso, zomwe zimapangitsa kulephera kwa impso (acute tubular necrosis).
  • Chizindikiro chochenjeza cha mkodzo wamtundu wa tiyi kapena wa kola: Ngati aliyense amene anagwidwa ndi vuto lamagetsi atulutsa mkodzo womwe umaoneka wopinki, wofiira, wofiirira-bulauni, wa tiyi wakuda, kapena wamtundu wa kola, ali ndi rhabdomyolysis yoopsa ndipo amafuna kuti amutsitsimutsenso madzimadzi m'mitsempha mwachangu m'chipatala.

4. Pediatric oral commissure (Electrical cord bite) amayaka

Ana aang'ono nthawi zina amatafuna zingwe zowonjezera kapena mapulagi ojambulira, kupanga arc yamagetsi pakona ya pakamwa. Mwana aliyense amene wapsa ndi magetsi a mkamwa ayenera kuunika kuchipatala. Pafupifupi masiku 5 mpaka 14 chivulale, nkhanambo yotuwa yakufayo imachoka ndipo imatha kulowa mu mtsempha wa labial, zomwe zimapangitsa kutuluka magazi mwadzidzidzi. Ngati magazi ayamba patatha masiku angapo, tsinani mlomo mwamphamvu pakati pa chala chachikulu (m'kamwa) ndi chala chamlozera (kunja kwa milomo) pogwiritsa ntchito nsalu yopyapyala yopyapyala ndikupita kuchipinda chodzidzimutsa.

Zofunikira pakuwunika kwa dipatimenti yadzidzidzi komanso kuwunika kwa ECG

Munthu aliyense amene akukumana ndi kugwedezeka kwa magetsi kuchokera ku mawaya a mains, zida, kapena mphezi ayenera kuwunikiridwa ndi dokotala. Zoyendera zaDipatimenti Yadzidzidzi Zadzidzidzi ndi 12-lead electrocardiogram (ECG) monitoring ndizofunikira ngati pali zotsatirazi:

  • Kulumikizana ndi mphamvu yamagetsi (> 1,000 V) kapena mphezi, kapena **kutayika kwa chidziwitso **, chisokonezo, kapena amnesia.
  • Njira iliyonse ya transthoracic (kumanja ndi dzanja kapena kumanja mpaka kumapazi) kapena yaitali "no-let-go" tetanic loko pawaya wapakhomo.
  • Kupweteka pachifuwa, kugunda kwa mtima, kupuma movutikira, kuwoneka **kulowa kapena kutuluka kukayaka **, kupweteka kwambiri kwa minofu, kapena mkodzo wakuda wa tiyi.
  • Mimba nthawi iliyonse (imafuna kuwunika msanga kwa fetal) kapena matenda amtima omwe analipo kale.

Tip

Ganizirani kutenga manja pa CPR, AED, ndi maphunziro a certification a thandizo loyamba kuchokera ku Red Cross, St John Ambulance, kapena American Heart Association. Kudziwa momwe mungamangirire pachifuwa ndikugwiritsira ntchito AED mutangothyola magetsi kuwirikiza kawiri mwayi wopulumuka kwa wozunzidwayo.

Mafunso omwe amafunsidwa pafupipafupi

Kodi kugwedezeka kwamagetsi kungayambitse matenda a mtima kapena kuchedwa kugunda kwa mtima patatha maola angapo ngati ndikumva bwino pompano?

Ngati munakumana ndi kugwedezeka kwamphamvu kwambiri (kupitirira 1,000 volts), kutaya chidziwitso ngakhale mwachidule, kupweteka kwakukulu kwa minofu kapena kuyaka, kapena kumva kupweteka pachifuwa kapena kugunda kwamtima, kuchedwa kwa mtima wa arrhythmias kumachitika patapita maola ambiri chifukwa cha kuvulala kwa myocardial kapena potaziyamu kuchokera ku maselo owonongeka a minofu, omwe amafunikira chipatala cha ECG-24. Pakudzidzimuka kwakanthawi kochepa kwapanyumba (120 V mpaka 240 V) pomwe simunakomoke ndikumva bwino, cheke chachipatala mwachangu chokhala ndi 12-lead electrocardiogram (ECG) chimaletsa kuchedwa kwachiwopsezo chamtima.

Chifukwa chiyani nyumba ya Alternating Current (AC) ili yowopsa kuposa Direct Current (DC) pamagetsi omwewo?

Kusinthasintha kwapakhomo kwapakhomo kumayenda mozungulira 50 kapena 60 pa sekondi imodzi (50/60 Hz), yomwe imapangitsa kuti chigoba cha anthu chikhale chokhazikika, chotsekeka cha tetanic spasm ( "no- let-go" phenomenon). Chifukwa minofu ya m'mphuno ndi yamphamvu kuposa ya extensor, dzanja la wovulalayo limagwira mwamphamvu kuzungulira waya wamoyo, zomwe zimawonjezera nthawi yomwe ikuyenda komanso kuphika kwamkati. Kuonjezera apo, 50/60 Hz AC imagunda mobwerezabwereza zenera la mtima la repolarization, zomwe zimachititsa kuti ventricular fibrillation ikhale yotsika katatu kapena kasanu kuposa DC.

Kodi ndi zotetezeka kugwiritsa ntchito ndodo yamatabwa kapena nthambi yowuma yamtengo kukankhira wina chingwe chamagetsi chotsika?

Ayi, musayese kugwiritsa ntchito ndodo yamatabwa, nthambi ya mtengo, chitoliro cha pulasitiki, kapena magolovesi amphira kuti musunthe chingwe chamagetsi chapamwamba kapena waya uliwonse wothamanga kwambiri (> 1,000 volts). Zida zosagwiritsa ntchito zapakhomo zimangoteteza kumagetsi otsika (110 V mpaka 240 V). Pamagetsi ogawa a 4,000 mpaka 35,000 volts, magetsi amayenda mopanda mphamvu kupyolera mumlengalenga ndikuyenda pansi pa chinyezi cha microscopic ndi njira za utomoni mu nkhuni kapena pulasitiki mwachindunji kupulumutsa, kupha anthu onse awiri. Nthawi zonse khalani kutali ndi 10 mpaka 20 metres (33 mpaka 65 mapazi) ndikudikirira kuti kampani yamagetsi ichotse mphamvu zamagetsi.

Kodi ndichifukwa chiyani ndiyenera kudumpha kapena kudumpha ndi mapazi onse pamodzi pafupi ndi chingwe chotsika ngakhale sindikugwira waya?

Waya wamphamvu kwambiri ukakhudza dziko lapansi, magetsi amatulukira kunja kupyola m'nthaka m'zing'onozing'ono zotsika mphamvu yamagetsi, ngati mafunde a m'dziwe. Ngati mukuyenda bwino, phazi lanu lakutsogolo limagwera pamagetsi amodzi pomwe phazi lanu lakumbuyo limakhudza mphete yamagetsi ena. Kusiyana kwa magetsi pakati pa mapazi anu (kuthekera kwa masitepe) kumapangitsa kuti magetsi azitha kuwombera mwendo umodzi, kudutsa m'chiuno ndi pamtima, ndi kutsika mwendo wina. Kumangirira mapazi onse pamodzi ndikugwedezeka kapena kudumpha kumapangitsa kuti mapazi onse azikhala pamagetsi omwewo kotero kuti palibe mayendedwe ozungulira thupi lanu.

Chifukwa chiyani wovulala wamagetsi amayenera kupita kuchipinda chodzidzimutsa ngati khungu lawo limangopsa pang'ono?

Kuvulala kwamagetsi kumatsatira "iceberg effect," pomwe 95 peresenti ya zowonongeka zimachitika kunja kwa thupi mkati mwa thupi. Chifukwa fupa limakhala ndi mphamvu yolimbana ndi magetsi kuposa minofu iliyonse, yomwe ikuyenda pa mkono kapena mwendo imatenthetsa fupa mpaka kutentha kwambiri, kuphika minofu yakuya yozungulira fupa ndikusiya khungu lakunja likuwoneka bwino. Kuwonongeka kwa minofu yakuya kumeneku kungayambitse matenda owopsa a ziwalo ndi kutulutsa mapuloteni a minofu (myoglobin) omwe amachititsa kulephera kwa impso mkati mwa maola ochepa.

Kodi mayi woyembekezera ayenera kuchita chiyani ngati alandira kugunda kwamagetsi kwapanyumba kwazing'ono?

Munthu aliyense woyembekezera amene agwidwa ndi magetsi otuluka m’nyumba, m’chingwe, kapena pa chingwe chosokonekera, makamaka ngati madziwo alowa m’manja n’kudutsa m’mapazi, ayenera kupita ku dipatimenti yoona za ngozi zadzidzidzi kapena kugawo la obereketsa mwamsanga, ngakhale ataona kuti sanavulale ndipo khungu lake silipsa. Amniotic fluid ndi kufalikira kwa mwana wosabadwayo kumapereka mphamvu yocheperako kwambiri yamagetsi, kutanthauza kuti kamadzi kakang'ono kamene kamangogwedeza dzanja la mayi kamadutsa mwachindunji m'chiberekero ndi kukhudza kugunda kwa mtima wa mwana kapena placenta.

Maupangiri ogwirizana

Magwero afufuzidwa

  • American Heart Association (AHA, United States) ndi International Liaison Committee on Resuscitation (ILCOR): Malangizo a Kutsitsimula kwa Cardiopulmonary ndi Emergency Cardiovascular Care (Zochitika Zapadera Zotsitsimula: Kuvulala kwa Magetsi ndi Mphezi)
  • European Resuscitation Council (ERC): Malangizo pa Kumangidwa kwa Mtima mu Zochitika Zapadera , Kugunda kwa Electrocution ndi Mphezi
  • Occupational Safety and Health Administration (OSHA, United States) ndi National Institute for Occupational Safety and Health (NIOSH / CDC, United States): Chitetezo cha Magetsi, Zomwe Zingatheke, ndi Arc Flash Trauma Directives
  • American Burn Association (ABA, United States): Advanced Burn Life Support (ABLS) Malangizo Othandizira Othandizira Kuvulala kwa Magetsi ndi Mphezi
  • National Health Service (NHS, United Kingdom) ndi St John Ambulance (United Kingdom): Ma Protocol a First Aid for High-Voltage and Low-Voltage Electric Shock