Skip to content

Electric shock first aid: what to do and what to avoid

အရေးပေါ်နံပါတ်များသည် နိုင်ငံအလိုက်ကွဲပြားသည်။. ဤစာမျက်နှာသည် အမေရိကန်နှင့် ကနေဒါအတွက် နံပါတ် ၉၁၁ ကို အသုံးပြုသည်။ အခြားနိုင်ငံအများအပြားတွင် 112၊ 999 သို့မဟုတ် အခြားနံပါတ်ကို အသုံးပြုသည်။ သင့်နိုင်ငံအတွက် နံပါတ်ကို ရှာပါ။.

Electrical injuries are among the most deceptive and complex emergencies in trauma medicine. While the visible skin contact points may appear as minor, pinpoint surface burns, electrical current passing through the human body converts into intense internal thermal energy along deep anatomical pathways. Within milliseconds, household or industrial current can induce involuntary muscle paralysis that locks the victim onto the live conductor, trigger lethal ventricular fibrillation or respiratory arrest, coagulate deep vascular networks, cook periosteal skeletal muscle against heated bone, and fracture the spine through violent tetanic contractions.

The absolute first rule of any electrical emergency is rescuer safety: touching a person who remains in contact with an energized electrical source turns you into an immediate secondary casualty. Knowing how to isolate household and commercial power, separate a low-voltage victim using dry non-conductive insulators, escape the concentric ground-voltage rings (step potential) of a downed high-voltage utility line, initiate immediate cardiopulmonary resuscitation (CPR), and recognize delayed internal complications such as rhabdomyolysis and compartment syndrome saves lives.

ယခုလုပ်ပါ။

  1. Do not touch the victim with your bare hands, clothing, or any metal or wet object while they are still touching the electrical source. The human body is an electrolytic conductor; grabbing an electrified person transfers the live current directly through your own heart and nervous system.
  2. Call emergency services immediately and state that an electrical injury has occurred. Call your local emergency number (911 in the United States and Canada, 112 across the European Union, 999 in the United Kingdom) or check အရေးပေါ်နံပါတ်များ, and request both paramedics and the electric utility company if high-voltage lines are involved.
  3. Shut off the electrical power source immediately if it is low-voltage household or commercial power (under 1,000 volts). Flip the main circuit breaker switch at the electrical service panel, unscrew the fuse, switch off the wall socket switch (where equipped), or pull the insulated rubber plug from the outlet if the cord is undamaged and away from water.
  4. Stay at least 10 to 20 meters (33 to 65 feet) back if the source is high-voltage (over 1,000 volts), a downed overhead power line, or lightning. Never attempt to pry a high-voltage wire off someone with a broomstick or wooden branch, because high-voltage electricity arcs through the air and travels down non-conductive poles; wait until utility technicians confirm the grid is de-energized and grounded.
  5. If low-voltage household power cannot be switched off immediately, push the victim or wire away using a completely dry, non-conductive object. Stand on a dry insulating surface (such as a rubber doormat, dry wooden board, or thick stack of newspapers) and use a dry wooden broom handle, fiberglass pole, dry PVC pipe, or looped dry cotton rope to break contact.
  6. Check responsiveness and breathing the instant the victim is clear of the electricity, and start CPR immediately if needed. If the person is unresponsive and not breathing normally (or only taking irregular agonal gasps), begin cardiopulmonary resuscitation (CPR) at 100 to 120 compressions per minute and attach an Automated External Defibrillator (AED) as soon as one arrives; if they are breathing, cool any visible burns with cool running water for 20 minutes and keep their neck and spine still.
flowchart TD
    Start["Person in Contact with Electrical Source"] --> HVCheck{"Is it High Voltage (>1,000 V), a downed power line, or wet environment?"}
    HVCheck -->|"Yes: High Voltage or Downed Line"| HVProtocol["Keep 10 to 20 meters (33 to 65 feet) away; NEVER approach or use poles"]
    HVProtocol --> CallUtil["Call 911 / 112 / 999 and electric utility; shuffle with feet together if inside zone"]
    HVCheck -->|"No: Low Voltage Household (110 V to 240 V)"| CutPower{"Can you safely shut off the breaker or unplug the cord?"}
    CutPower -->|"ဟုတ်ကဲ့"| PowerOff["Flip main circuit breaker to Off or pull insulated plug"]
    CutPower -->|"မရှိ"| Insulate["Stand on dry rubber or wood; push wire or victim away with dry wood or plastic tool"]
    PowerOff --> Assess["Victim Free of Current: Check responsiveness and breathing for 10 seconds"]
    Insulate --> Assess
    Assess --> BreathCheck{"Is the victim responsive and breathing normally?"}
    BreathCheck -->|"No (Unresponsive / Agonal gasps)"| StartCPR["Start CPR (30:2 or Hands-Only) at 100 to 120 bpm and apply AED immediately"]
    BreathCheck -->|"Yes (Breathing normally)"| TraumaCare["Immobilize spine if fallen, cool burns with cool running water for 20 min, transport to ER"]

Physics and pathophysiology of electrical trauma

When an electrical circuit forms across the human body, the severity of cellular and organ destruction is governed by six physical variables summarized by Ohm's Law (\(I = V / R\), where current equals voltage divided by resistance) and Joule's First Law of Heating (\(Q = I2 \times R \times t\), where thermal heat generated equals the square of the current multiplied by tissue resistance and contact duration):

  1. Amperage (Current intensity in milliamperes, mA): Amperage is the primary physiological killer, determined by the driving voltage divided by skin and internal tissue resistance.
  2. Voltage (Electrical potential in volts, V): Divided clinically into low voltage (under 1,000 volts, such as 120 V North American mains, 230 V European/UK/Australian mains, and 400 V three-phase commercial wiring) and high voltage (1,000 volts and above, such as overhead utility distribution lines carrying 4,160 V to 34,500 V and transmission towers carrying 115,000 V to 765,000 V).
  3. Resistance (Impedance in ohms, \(\Omega\)): Dry, calloused human palms offer high resistance (up to 40,000 to 100,000 ohms), which limits current flow. However, wet skin, sweaty skin, immersed skin in a bathtub, or broken skin drops epidermal resistance down to 500 to 1,000 ohms. At 1,000 ohms of wet skin resistance, touching a standard 120-volt or 230-volt bathroom appliance delivers 120 to 230 milliamperes directly into the bloodstream, which is more than enough to trigger instant cardiac arrest.
  4. ** လျှပ်စီးကြောင်းအမျိုးအစား- Alternating Current (AC) နှင့် Direct Current (DC)။**
  5. ခန္ဓာဗေဒလမ်းကြောင်း (Transthoracic vs vertical): လျှပ်စစ်ခုခံမှုအနည်းဆုံးလမ်းကြောင်း (သွေးကြောများ၊ အာရုံကြောများနှင့် ကြွက်သားများ) ဝင်ပေါက်ဆက်သွယ်ချက် မှ မြေပြင်ထွက်ပေါက်အမှတ် ဆီသို့ လက်ရှိ သွားလာနေသည်။
  6. Hand-to-hand (အလျားလိုက် transthoracic pathway): Current သည် လက်တစ်ဖက်သို့ ဝင်ရောက်ပြီး mediastinum နှင့် နှလုံးကို တိုက်ရိုက်ဖြတ်ကာ ဆန့်ကျင်ဘက်လက်မှ ထွက်သည်။ ဤလမ်းကြောင်းသည် တိုက်ရိုက် myocardial fibrillation ကြောင့် အမြင့်ဆုံးသေဆုံးမှုနှုန်း (ဗို့အားမြင့်အဆက်အသွယ်များတွင် ~ 60 ရာခိုင်နှုန်း) ရှိသည်။
  7. လက်မှခြေလျင် (ဒေါင်လိုက်လမ်းကြောင်း)- လက်ရှိသည် ရင်ဘတ်၊ ဝမ်းဗိုက်အင်္ဂါများနှင့် ခြေထောက်ကို ကြမ်းပြင်သို့ ဖြတ်သန်းသွားပါသည်။
  8. ခြေမှခြေလျင် (လမ်းလျှောက်ခြင်း သို့မဟုတ် ခြေတစ်လှမ်းလှမ်းခြင်း) အလားအလာ- လက်ရှိသည် ခြေတစ်လှမ်းသို့ ဝင်ရောက်ကာ တင်ပါးဆုံရိုးကိုဖြတ်ကာ အခြားခြေတစ်ဖက်မှ ထွက်သည်။
  9. ** ထိတွေ့မှုကြာချိန် (\(t\)):** ခန္ဓာကိုယ်သည် ဝါယာကြိုးနှင့် ဆက်နွယ်နေလေလေ၊ အပူရှိန်များ နက်ရှိုင်းသော တစ်ရှူးများအတွင်း စုပုံလာလေလေ၊ အရေပြားများ ပြိုကွဲသွားကာ ခုခံနိုင်စွမ်းကို ပိုမိုကျဆင်းစေပြီး စီးဆင်းမှုကို အရှိန်မြှင့်ပေးသည်။

milliamperes အားဖြင့် 50/60 Hz AC လျှပ်စီးကြောင်း၏ ဇီဝကမ္မဆိုင်ရာသက်ရောက်မှုများ

လက်ရှိ ပြင်းထန်မှု (mA၊ 1 စက္ကန့် အဆက်အသွယ်) လူ့ခန္ဓာကိုယ်အပေါ်ဇီဝကမ္မအကျိုးသက်ရောက်မှု လက်တွေ့ရလဒ်
** 1 မှ 3 mA ** အာရုံသညာ၏ တံခါးခုံ လက်ချောင်းထိပ်များတွင် ပျော့ပျောင်းသောခံစားမှု၊ တစ်ရှူးပျက်စီးမှုမရှိပါ။
5 မှ 10 mA နာကျင်သော အာရုံ တုန်လှုပ်ခြင်း။ စူးရှသောနာကျင်မှု; သာမန်အရွယ်ရောက်ပြီးသူများသည် ၎င်းတို့၏ ချုပ်ကိုင်မှုကို ဆန္ဒအလျောက် လွှတ်နိုင်ဆဲဖြစ်သည် ("လွှတ်-လွှတ်" လက်ရှိ)
** 10 မှ 20 mA ** ** "သွားခွင့်ပြုပါ" အဆင့် (Flexor Tetany)** လက်ဖျံ flexor ကြွက်သားများ၏ အလိုအလျောက် tetanic ကျုံ့သွားခြင်းသည် လက်ကို ဝိုင်ယာကြိုးတစ်ဝိုက်တွင် တင်းတင်းကျပ်ကျပ် သော့ခတ်ပေးသည်။ သားကောင် မလွှတ်နိုင်ဘူး
20 မှ 50 mA ** Thoracic နှင့် Diaphragmatic Tetany ** diaphragm နှင့် intercostal အသက်ရှူကြွက်သားများအဆက်မပြတ်သွက်ချာပါဒ; အသက်ရှူလမ်းကြောင်းပိတ်ခြင်း နှင့် ထိတွေ့မှုဆက်ရှိနေပါက အသက်ရှုကြပ်ခြင်းကို ဖြစ်စေသည်။
50 မှ 100 mA ** Ventricular Fibrillation (V-Fib) အဆင့်** ထိခိုက်လွယ်သော T-wave repolarization ပြတင်းပေါက်အတွင်း လျှပ်စစ်စီးကြောင်းသည် နှလုံးကို ဖရိုဖရဲဖြစ်စေသော ဖရိုဖရဲဖြစ်စေခြင်းသို့ ဖြစ်စေသည်
1,000 မှ 4,000 mA (1 မှ 4 Amps) Sustained Myocardial Contraction (Asystole) နှင့် Deep Thermal Burns ကြီးမားသော အတွင်းပိုင်းတစ်သျှူးချက်ပြုတ်ခြင်းနှင့် ပေါင်းစပ်ထားသော နှလုံးကြွက်သားများ၏ ရပ်တန့်ခြင်းကို အပြည့်အဝ ကုပ်ထားသည်။

Alternating Current (AC) နှင့် Direct Current (DC)

လက်တွေ့နှင့်ရုပ်ပိုင်းဆိုင်ရာအင်္ဂါရပ် Alternating Current (AC: 50 Hz / 60 Hz) တိုက်ရိုက်လျှပ်စီးကြောင်း (DC)
ကမ္ဘာ့အစစ်အမှန်အရင်းအမြစ်များ အိမ်သုံး နံရံပလပ်ပေါက်များ (120 V / 230 V)၊ မီးဖိုချောင်သုံးပစ္စည်းများ၊ ဓာတ်အားကိရိယာများ၊ လုပ်ငန်းသုံး HVAC၊ ပေါ်ရှိ အသုံးအဆောင်လိုင်းများ မော်တော်ကားနှင့် EV ဘက္ထရီအထုပ်များ (12 V မှ 800 V)၊ ဆိုလာဓာတ်ပုံဗိုလ်တာအခင်းများ၊ လျှပ်စစ်မီးရရှိထားသော မြေအောက်ရထားတတိယသံလမ်းများ၊ ဂဟေဆော်သူများ၊ လျှပ်စီးကြောင်းများ
အရိုးစု ကြွက်သား တုံ့ပြန်မှု အဆက်မပြတ် tetanic spasm ("မလွှတ်ဘူး" ဖြစ်စဉ်): လက်ရှိ ဦးတည်ချက်သည် တစ်စက္ကန့်လျှင် 50 မှ 60 ကြိမ်သို့ ပြောင်းပြန်ဖြစ်သောကြောင့် လက်ဖျံကြွက်သားများသည် အဆက်မပြတ် ကျုံ့သွားပြီး သားကောင်၏လက်သီးအား တိုက်ရိုက်ဝါယာကြိုးပေါ်သို့ ချည်နှောင်ထားသည်။ ** ပြင်းထန်သော ပဲ့ထိန်း တစ်ချက် ကျုံ့ခြင်း-** ကြီးမားသော ကြွက်သား တောင့်တင်းမှုကို ဖြစ်ပေါ်စေပြီး စွမ်းအား အရင်းအမြစ်မှ မီတာများစွာ နောက်သို့ မကြာခဏ နောက်သို့ မကြာခဏ ပစ်ချပေးသည်။
** Primary Cardiac Arrhythmia ** Ventricular Fibrillation (V-Fib)- 50/60 Hz စက်ဝန်းသည် ထိခိုက်လွယ်သော နှလုံးပြန်ပိုလာခြင်းအဆင့်ကို ထပ်ခါတလဲလဲ ဖြတ်သွားသောကြောင့် ဗို့အားနိမ့် DC ထက် 3 မှ 5 ဆ ပိုအန္တရာယ်ရှိသည်။ ** Ventricular Asystole (Cardiac Standstill):** ဗို့အားမြင့် DC သည် myocardium တစ်ခုလုံးကို တစ်ပြိုင်နက် ဖယ်ထုတ်ပြီး နှလုံးခုန်ခြင်းကို လုံးဝရပ်တန့်စေသည်
ဆက်စပ်ဒဏ်ရာ ပရိုဖိုင် ရှည်လျားသော ထိတွေ့မှုအချိန်သည် နက်ရှိုင်းသော အတွင်းပိုင်းအပူဒဏ်၊ အသက်ရှူလမ်းကြောင်းဆိုင်ရာ အသက်ရှုကြပ်ခြင်း နှင့် တွင်းဝင်ပေါက်/ထွက်ပေါက်များ ထူထပ်စွာ လောင်ကျွမ်းခြင်းတို့ကို ဖြစ်စေသည်။ ထိတွေ့ချိန်ပိုတိုသော်လည်း တုံးအရိုးအရိုးဒဏ်ရာ (ဦးခေါင်းခွံရိုးကျိုးခြင်း၊ သားအိမ်ခေါင်း ကျောရိုးကျိုးခြင်း၊ သရက်ရွက်ပေါက်ပြဲခြင်း၊ လှေကားပေါ်မှ ပြုတ်ကျခြင်း သို့မဟုတ် လှေကားများပေါ်မှ ပြုတ်ကျခြင်း၊

ဘေးကင်းသော ကယ်တင်ရေး ပရိုတိုကောများ- လျှပ်စစ်အဆက်အသွယ်ကို ချိုးဖျက်ခြင်း။

Danger

ပြိုကျနေသော ခေါင်းစီးဓာတ်အားလိုင်း၊ ဓာတ်အားခွဲရုံမှ ထရန်စဖော်မာ၊ လျှပ်စစ်ရထားရထား သို့မဟုတ် ဗို့အား 1,000 ဗို့ထက် ကျော်လွန်သည့် လျှပ်စစ်ဓာတ်အားလိုင်း၏ 10 မီတာ (33 ပေ) အတွင်း မည်သည့်အခါမျှ ဗို့အားမြင့်ဝါယာကြိုးကို သစ်သားတံမြက်စည်း၊ သစ်ပင်ကိုင်း သို့မဟုတ် ပလပ်စတစ်ကိရိယာဖြင့် ရွှေ့ရန် ဘယ်သောအခါမှ မကြိုးစားပါနှင့်။ ဗို့အားမြင့်လျှပ်စစ်က လေကို အိုင်ယွန်အိုင်ယွန်ဖြစ်စေပြီး ပွင့်လင်းသောနေရာကိုဖြတ်ကာ (arc) ခုန်ကာ သစ်သား သို့မဟုတ် ပလပ်စတစ်၏ မျက်နှာပြင်အစိုဓာတ်ကို သင့်ခန္ဓာကိုယ်ထဲသို့ တိုက်ရိုက်စီးဆင်းစေသည်။

1. ဗို့အားနိမ့်အိမ်ထောင်စုနှင့် လုပ်ငန်းခွင်ကယ်ဆယ်ရေး (1,000 ဗို့အောက်)

တစ်စုံတစ်ယောက်သည် 120-volt သို့မဟုတ် 230-volt အိမ်သုံးပစ္စည်း၊ တိုးချဲ့ကြိုး၊ ပါဝါတူးလ် သို့မဟုတ် ချို့ယွင်းနေသော ခလုတ်ကြောင့် တစ်စုံတစ်ယောက် တုန်လှုပ်သွားသောအခါ-

  1. ** အရင်းအမြစ်ရှိပါဝါကို ဦးစွာဖြတ်ပါ (အမြဲတမ်းအလုံခြုံဆုံးနည်းလမ်း):**
  2. အိမ်သုံးလျှပ်စစ်ဖြန့်ဖြူးမှုအကန့် (fuse box သို့မဟုတ် breaker box) သို့ပြေးပြီး Main Breaker ကို Off အနေအထားသို့ လှန်ပါ၊ သို့မဟုတ် သီးခြားခွဲထားသော circuit breaker ကိုလှန်ပါ။
  3. United Kingdom၊ Europe နှင့် Australia တွင် wall sockets များတွင် တစ်ဦးချင်းစီ rocker switch များပါရှိသည်။ အကယ်၍ နံရံ socket သည် ခြောက်သွေ့နေပြီး သားကောင် သို့မဟုတ် စက်ကို မထိဘဲ ၎င်းကို ရောက်ရှိနိုင်ပါက လျှပ်ကူးနိုင်သော အရာမဟုတ်သော ခြောက်သွေ့သော အရာတစ်ခုဖြင့် socket ခလုတ်ကို ပိတ်ပြီး ပလပ်ကို ဆွဲထုတ်ပါ။
  4. အကယ်၍ သေဆုံးသူသည် စိုစွတ်သောနေရာတွင် (ရေချိုးခန်းကြမ်းပြင်၊ ရေလွှမ်းနေသော မြေအောက်ခန်း၊ ရေကူးကန်ကြမ်းပြင် သို့မဟုတ် စိုစွတ်သောမြက်ခင်းပြင်) တွင် စက်ပစ္စည်းကို ကိုင်ဆောင်ထားပါက ** စိုစွတ်သောကြမ်းပြင်ပေါ်သို့ မတက်ပါ သို့မဟုတ် စက်ကြိုးကို မထိပါနှင့်**။ ခြောက်သွေ့သောအခင်းပေါ်တွင် ရပ်နေစဉ် ပင်မအိမ်ဘရိတ်ကာအကန့်တွင် ပါဝါပိတ်ပါ။
  5. ** breaker က ဆက်သွယ်လို့မရတဲ့အခါ သားကောင်ကို ဘယ်လိုခွဲရမလဲ။
  6. အကယ်၍ သင်သည် စက္ကန့်ပိုင်းအတွင်း circuit breaker သို့ မရောက်ရှိနိုင်ဘဲ သားကောင်အား ခြောက်သွေ့သော အတွင်းခန်းကြမ်းပြင်တွင် tetanic spasm ဖြင့် သော့ခတ်ထားပါက၊ သင်သည် မြေ နှင့် သားကောင် နှစ်ခုလုံးမှ သင့်ကိုယ်သင် အကာအကွယ်ပေးရပါမည်။
  7. အဆင့် A (သင့်ခြေထောက်ကို ကာရံထားရန်): ရာဘာတံခါးဖျာ၊ ရော်ဘာကြမ်းခင်းထားသော အလုပ်ဘွတ်ဖိနပ်တစ်စုံ၊ ခြောက်သွေ့သော သစ်သားညှပ်ဘုတ်၊ သို့မဟုတ် စာအုပ်ခြောက်အုပ် သို့မဟုတ် ခေါက်သုတ်ပုဝါခြောက်ကဲ့သို့သော ထူထဲပြီး ခြောက်သွေ့သော၊ လျှပ်ကူးမှုမရှိသော ပစ္စည်းပေါ်တွင် ရပ်တည်ပါ။
  8. အဆင့် B (လျှပ်ကူးနိုင်သောပစ္စည်းမဟုတ်သော ခြောက်သွေ့သောကိရိယာကို ရွေးချယ်ပါ)- သန့်စင်သော လျှပ်ကာပစ္စည်းဖြင့် ပြုလုပ်ထားသည့် ရှည်လျားသော အရာဝတ္တု- သစ်သားတံမြက်စည်း လက်ကိုင်တံခြောက်၊ သစ်သားထိုင်ခုံခြောက်၊ ပလပ်စတစ်အစိုင်အခဲ သို့မဟုတ် PVC ပိုက်၊ ဖိုက်ဘာမှန် ကိရိယာလက်ကိုင်၊ သို့မဟုတ် ခြောက်လှိမ့်ထားသော ချည်စောင် သို့မဟုတ် ခြောက်သွေ့သော နိုင်လွန်ကြိုးတစ်ချောင်း သို့မဟုတ် သားကောင်၏ ကိုယ်လက်အင်္ဂါများ သို့မဟုတ် အဝတ်အစားများ ပတ်ပတ်လည်တွင် ရစ်ပတ်ထားသော နိုင်လွန်ကြိုးခြောက်။
  9. အဆင့် C (သတ္တု သို့မဟုတ် အစိုဓာတ်ကို စစ်ဆေးပါ)- တံမြက်စည်းလက်ကိုင်တွင် သတ္တုတွဲလောင်းဦးထုပ်၊ စိုစွတ်သောဆေး၊ သို့မဟုတ် အစိုဓာတ်မပါဝင်ကြောင်း သေချာစေပြီး သားကောင်၏ဗလာဖြစ်နေသော အရေပြား သို့မဟုတ် စိုစွတ်သောချွေးစေးများသောအဝတ်အစားများကို ဘယ်သောအခါမှ မဆုပ်ကိုင်ပါ။
  10. အဆင့် D (ပြတ်သားသောလေဖြတ်ခြင်းတွင် အဆက်အသွယ်ဖြတ်ပါ)- သစ်သားတိုင်ကို အသုံးပြု၍ သားကောင်၏လက်ကို ဝိုင်ယာကြိုးကို တွန်းဖယ်ရန် သို့မဟုတ် ကိရိယာကြိုးကို သားကောင်နှင့်ဝေးရာသို့ ခေါက်ပါ၊ သို့မှသာ ၎င်းတို့သည် တိုက်ရိုက်စပယ်ယာပေါ်သို့ ပြန်မကျသွားစေရန် သစ်သားတိုင်ကို အသုံးပြုပါ။

2. ဗို့အားမြင့် အရေးပေါ်အခြေအနေများ၊ ဓာတ်အားလိုင်းများ ပြတ်တောက်မှုနှင့် အဆင့်အလားအလာ

မုန်တိုင်းတစ်ခု သို့မဟုတ် ကားတိုက်မှုအတွင်း မြေပြင်၊ လမ်း၊ ခြံစည်းရိုး သို့မဟုတ် သစ်ပင်ပေါ်သို့ ပြုတ်ကျသောအခါ၊ မမြင်နိုင်သော ရုပ်ပိုင်းဆိုင်ရာ အန္တရာယ်နှစ်ခုသည် ဆက်သွယ်ချက်အမှတ်တစ်ဝိုက်တွင် ချက်ချင်းဖြစ်ပေါ်သည်- လျှပ်စစ်ဓာတ်အားပြိုင်ခြင်း နှင့် မြေပြင်ခြေလှမ်းအလားအလာ (ဗို့အားအရောင်ပြောင်းမှု)။

ခြေလှမ်းအလားအလာကို နားလည်ပြီး ထိတွေ့နိုင်မှုအလားအလာ

တိုက်ရိုက်ဗို့အားမြင့်ကေဘယ်လ်တစ်ခုသည် မြေကြီးပေါ်တွင် တည်ရှိနေသည့်အခါ အထူးသဖြင့် မြေဆီလွှာ၊ ခြောက်သွေ့သောကတ္တရာ သို့မဟုတ် သစ်ပင်အကိုင်းအခက်သည် အလယ်အလတ် impedance ပေးဆောင်နေပါက၊ ၎င်းသည် utility substation breaker ကို အမြဲတမ်း လည်ပတ်နေမည်မဟုတ်ပေ။ ယင်းအစား၊ ထောင်ပေါင်းများစွာသော လျှပ်စစ်ဓာတ်အား ဗို့အားများသည် မြေကြီးထဲသို့ အဆက်မပြတ် သွန်းလောင်းပြီး အပြင်သို့ ပြန့်ကျဲနေသော ဗို့အားကျဆင်းနေသော ဗဟိုချက်ချာသော စက်ဝိုင်းအဝိုင်း၊ ကျောက်တုံးကြီးတစ်ခုထဲသို့ ပြုတ်ကျသောအခါ အပြင်ဘက်သို့ ပျံ့နှံ့သွားသည့် လှိုင်းဂယက်များကဲ့သို့ပင်။

  • မြေပြင်ရှိ ဝါယာကြိုးကို တိုက်ရိုက်ထိမိပါက မြေဆီလွှာသည် 15,000 ဗို့ တွင် ရှိနေနိုင်သည်။
  • 2 မီတာ (6.5 ပေ) အကွာတွင်၊ မြေဆီလွှာသည် ** 10,000 ဗို့** တွင်ရှိနိုင်သည်။
  • 4 မီတာ (13 ပေ) အကွာတွင်၊ မြေဆီလွှာသည် ** 6,000 ဗို့** တွင်ရှိနိုင်သည်။
  • 10 မီတာ (33 ပေ) အကွာတွင် မြေဆီလွှာသည် 0 ဗို့ ဆီသို့ ကျဆင်းသွားသည်။

ကယ်ဆယ်သူသည် ဤဗဟိုပြုဇုန်ထဲသို့ ပုံမှန် 0.8 မီတာ (2.5 ပေ) ပြေးခြင်း သို့မဟုတ် လမ်းလျှောက်ပါက၊ ၎င်းတို့၏ ရှေ့ခြေများသည် 8,000-volt ring ပေါ်ရှိ ၎င်းတို့၏ နောက်ခြေထောက်များသည် 10,000-volt ring ပေါ်တွင် တည်နေပါသည်။ သူတို့၏ခြေနှစ်ချောင်းကြားရှိ 2,000-volt ကွာခြားချက် (ခြေလှမ်းအလားအလာ) သည် ခုခံမှုမြင့်မားသောအညစ်အကြေးများပေါ်မှ ခုခံမှုနည်းသောလူ့ခန္ဓာကိုယ်ကို ချက်ချင်းရွေးချယ်သည်- လက်ရှိခြေထောက်တစ်ဖက်၊ တင်ပါးဆုံတွင်းအင်္ဂါများနှင့် နှလုံးမှတစ်ဆင့် အခြားခြေထောက်တစ်ဘက်သို့ ဖြတ်သွားကာ၊ မြေပြင်ပေါ်သို့ tetanic ချက်ခြင်းပြိုလဲသွားကာ၊ အလျားလိုက်ခန္ဓာကိုယ်သည် ယခုအခါ အဆီပိုများ (**ဗို့အားပို၍ကျယ်သွားသည်)။

အလားတူ၊ touch potential သည် လူတစ်ဦး မြေပြင်ပေါ်တွင် မတ်တပ်ရပ်ပြီး မီတာရာနှင့်ချီ၍ ပြိုကျနေသော ဓာတ်အားလိုင်းကို မီတာရာနှင့်ချီ၍ ပြုတ်ကျနေသော သတ္တုကွင်းဆက်ခြံစည်းရိုး၊ သတ္တုကိုယ်ထည်၊ သို့မဟုတ် ယာဉ်ကိုယ်ထည်ကို ထိသောအခါ ဖြစ်ပေါ်သည်။

ပြိုကျနေသည့် ဓာတ်အားလိုင်းဇုန် (Shuffle or Bunny-Hop)

ပြုတ်ကျနေသော ဓာတ်အားလိုင်းမှ 10 မီတာ မှ 20 မီတာ (33 မှ 65 ပေ) အကွာတွင် ရပ်နေသည်ကို ရုတ်တရက် သတိထားမိပါက သို့မဟုတ် သင့်ခြေထောက်နှင့် ခြေထောက်များတွင် နာကျင်ခြင်း ခံစားရပါက၊

  1. သင့်ရဲ့ခြေလှမ်းကို ချက်ချင်းရပ်လိုက်ပါ- နောက်ထပ်လမ်းလျှောက်တဲ့ခြေလှမ်းကို မလှမ်းပါနဲ့၊ ဘယ်တော့မှ မပြေးပါနဲ့။
  2. ** ခြေနှစ်ချောင်း မွှေနှောက်နည်းကို သုံးပါ-**
  3. Press your ankles and the inner edges of both shoes tightly together so your feet touch side-by-side.
  4. Slowly shuffle backward or away from the downed wire by sliding one foot forward only a few centimeters along the ground so the heel of your leading foot never passes the toes of your trailing foot, keeping both soles in continuous contact with the same voltage ring.
  5. Or use the Two-Foot Bunny-Hop method:
  6. Press your knees, ankles, and feet tightly together, cross your arms firmly against your chest so you do not lose balance and touch the ground with your hands, and hop away with both feet leaving and landing on the ground at the exact same instant.
  7. Never hop on one foot (if you fall over, your outstretched body will span multiple voltage rings).
  8. Continue shuffling or hopping until you are at least 10 meters (33 feet) away on dry ground, or 20 meters (65 feet) away if the pavement or grass is wet.

3. Trapped inside a vehicle touching a downed power line

If a utility pole falls across your car or truck:

  1. Stay inside the vehicle: As long as the car is not on fire, the safest place is sitting calmly inside the cabin. The metal body of the car acts as a Faraday cage while the rubber tires provide partial insulation, routing electricity around the exterior skin. Do not touch the metal door frames, window cranks, or radio, and call 911, 112, or 999 on your mobile phone. Warn bystanders loudly through a cracked window to stay at least 15 meters (50 feet) back.
  2. Emergency jump-and-shuffle evacuation (ONLY if the vehicle catches fire):
  3. If smoke or flames break out in the engine bay or cabin, you must exit without ever touching the metal car and the ground at the same time (which would turn your body into a direct ground bridge):
  4. Open the car door wide, being careful not to touch the exterior painted metal panel.
  5. Stand up on the interior floorboard or plastic door sill, cross your arms tightly over your chest, and tuck your chin.
  6. Jump clear of the vehicle so that both feet leave the car before either foot touches the ground, and land with both feet pressed tightly together.
  7. Do not stumble backward and touch the car with your hand. Immediately shuffle or bunny-hop with both feet together for at least 15 meters (50 feet) before walking normally.

Step-by-step medical first aid once the victim is clear

Once the power is off or the victim has been safely separated from the conductor, electrical trauma requires a structured C-A-B-C-D-E trauma resuscitation approach because electrical shock simultaneously causes cardiac arrest, central respiratory paralysis, spinal fractures, and thermal burns.

Step 1: Assess responsiveness, breathing, and start CPR / AED

  1. Tap the victim's shoulders and shout to check responsiveness while scanning the chest for normal breathing for no more than 10 seconds.
  2. Why prolonged CPR is essential in electric shock and lightning:
  3. သွေးကြောပိတ်ဆို့ခြင်းခံရသူ သက်ကြီးရွယ်အိုများနှင့်မတူဘဲ လျှပ်စစ်ရှော့ခ်ဖြစ်ခြင်း သို့မဟုတ် လျှပ်စီးလက်ခြင်းခံရသူများသည် မကြာခဏဆိုသလိုပင် နှလုံးလမ်းကြောင်းစနစ်သည် ** ventricular fibrillation (AC) မှ ပေါက်တတ်ကရ” သို့မဟုတ် ** asystole (DC/lightning)** သို့မဟုတ် ဦးနှောက်ပင်စည်အသက်ရှူလမ်းကြောင်းဆိုင်ရာဗဟိုချက်တွင် ထိတ်လန့်တုန်လှုပ်သွားလေ့ရှိသည်။
  4. အကယ်၍ လျှပ်စစ်ဓာတ်လိုက်ခံရသူ၏ နှလုံးခုန်နှုန်းသည် ဆက်လက်ခုန်နေမည် (သို့မဟုတ် လျှင်မြန်စွာ ပြန်လည်စတင်သည်) သို့သော် ၎င်းတို့၏ ဦးနှောက်ပင်စည် အသက်ရှူစင်တာသည် အံ့အားသင့်နေပါက၊ တစ်စုံတစ်ဦးမှ ၎င်းတို့အား ကယ်တင်ရေးအသက်ရှူခြင်းနှင့် ရင်ဘတ်ကိုဖိခြင်း မပေးပါက ၎င်းတို့သည် မိနစ်ပိုင်းအတွင်း နှလုံးခုန်ရပ်သွားကာ ဒုတိယမြောက် နှလုံးသွေးကြောပိတ်သေဆုံးသွားမည်ဖြစ်သည်။
  5. သေဆုံးသူအများအပြား မိုးကြိုးပစ်ခြင်း သို့မဟုတ် ဗို့အားမြင့်တိုက်ခိုက်မှုများတွင် နောက်ပြန်လှည့်ခြင်း- ပုံမှန်အားဖြင့်၊ အစုလိုက်အပြုံလိုက်သေဆုံးသည့် ဘေးအန္တရာယ်များတွင် ကယ်ဆယ်ရေးသမားများသည် အသက်ရှုခံရသူများကို ဦးစွာကုသပြီး အသက်ရှူကျပ်ခြင်း/သွေးခုန်နှုန်းမရှိသော သားကောင်များကို ကျော်ဖြတ်ကြသည်။ လျှပ်စီးလက်ခြင်း သို့မဟုတ် လျှပ်စစ်တိုက်ခိုက်မှုများတွင် စည်းမျဉ်းကို ပြောင်းပြန်လှန်လိုက်သည် ("သေဆုံးသူများကို ကယ်တင်ပါ")- ညည်းတွားပြီး လှုပ်ရှားနေသော သားကောင်များသည် နှလုံးခုန်နေပြီး အသက်ရှင်နိုင်ခြေရှိသော်လည်း မြေပြင်ပေါ်ရှိ မလှုပ်မယှက် အပြာရောင်သားကောင်သည် နောက်ပြန်လှည့်နိုင်သော ventricular fibrillation သို့မဟုတ် ဦးနှောက်ပင်စည်အသက်ရှူလမ်းကြောင်းဆိုင်ရာ ရပ်တန့်သွားပြီး ချက်ခြင်းကယ်တင်နိုင်သည်။ CPR နှင့် AED defibrillation.
  6. ** အရည်အသွေးမြင့် CPR ပေးပို့ခြင်း (30 ဖိသိပ်မှု 2 ကြိမ်သို့ ကယ်ဆယ်ခြင်း) ပေးပို့ပါ):**
  7. အရွယ်ရောက်ပြီးသူများတွင် ** 100 မှ 120 အထိ တစ်မိနစ်လျှင် ** 100 မှ 120 အထိ ရင်ဘတ်အလယ်ကို ပြင်းပြင်းထန်ထန် တွန်းထုတ်ပါ။
  8. အသက်ရှုလမ်းကြောင်းဆိုင်ရာ လေဖြတ်ခြင်းမှာ ရင်သားနှင့် ဦးနှောက်၏ ရင်သပ်ရှုမောဖွယ် လက္ခဏာရပ်ဖြစ်သောကြောင့်၊ ပြုတ်ကျခြင်း သို့မဟုတ် ကျောရိုးဒဏ်ရာဟု သံသယရှိလျှင် မေးရိုးထိုးခြင်း လေ့ကျင့်ခန်းကို အသုံးပြု၍ တတ်နိုင်လျှင် ** 2 ကြိမ် ဖိသွင်းပြီးနောက် ကယ်ဆယ်ရေး 2 ကြိမ်** ပါဝင်ပါ။
  9. Automated External Defibrillator (AED) ရောက်ရှိလာသည်နှင့် တပြိုင်နက် ချိတ်ဆက်ပါ။ သားကောင်၏ ရင်ဘတ်ကို ရေ သို့မဟုတ် ချွေးများ ခြောက်အောင် သုတ်ပြီး ဖြစ်နိုင်ပါက မီးလောင်ထားသော ဝင်ပေါက်မှ အနည်းဆုံး 2.5 စင်တီမီတာ (1 လက်မ) အကွာတွင် ကပ်ထားခြင်းဖြင့် အရေပြား char သည် တုန်လှုပ်ခြောက်ခြားမှု မဖြစ်အောင် တားဆီးပါ။

အဆင့် 2- သားအိမ်ခေါင်း ကျောရိုးကို ပိတ်ဆို့ပြီး တုံးတိဒဏ်ရာ ရှိမရှိ စစ်ဆေးပါ။

ကျောရိုးကို မစဉ်းစားဘဲ လျှပ်စစ်ရှော့တိုက်ခံရသူကို တည့်တည့်မလှုပ်ပါနှင့်။

  • ဗို့အားမြင့် တုန်ခါမှုများနှင့် DC ဆောင့်ချက်များသည် ပြင်းထန်သော၊ တပြိုင်နက်တည်း ကျုံ့သွားသော ကြွက်သားများကို ပြင်းထန်စွာ ကျုံ့စေပြီး၊ သားကောင်သည် ဘယ်သောအခါမှ မပြုတ်ကျသော်လည်း ရင်ခေါင်းနှင့် lumbar vertebrae** သို့မဟုတ် posterior shoulder dislocations တို့ကို ဖြစ်စေနိုင်သည်။
  • ထို့ပြင် လှေကားများ၊ ငြမ်းများ၊ သို့မဟုတ် မီးတိုင်များပေါ်တွင် ရပ်နေချိန်တွင် လျှပ်စစ်သမားများ၊ အိမ်ခေါင်မိုးနှင့် အိမ်ပိုင်ရှင်များသည် မကြာခဏ လျှပ်စစ်ရှော့တိုက်ခံရတတ်သည်။
  • သားကောင်အား ကျောပေါ်တွင် လှဲလျောင်းနေစေပြီး ပြုတ်ကျပါက သို့မဟုတ် ပစ်ချခံရပါက လက်နှစ်ဖက်ဖြင့် ဦးခေါင်းနှင့် လည်ပင်းကို တည်ငြိမ်အောင်ထိန်းကာ အသက်အန္တရာယ်ရှိသော သွေးလွှတ်ကြောများကို စစ်ဆေးပါ။ သွေးထွက်ခြင်း။. သေဆုံးသူသည် သတိလစ်နေပြီး ပုံမှန်အတိုင်း အသက်ရှုကာ အော့အန်ပါက ဦးခေါင်း၊ လည်ပင်းနှင့် ခန္ဓာကိုယ်ကို ညီအောင်ထိန်းထားစဉ်တွင် ၎င်းတို့၏ ခန္ဓာကိုယ်တစ်ခုလုံးအား တောင့်တင်းသောယူနစ်တစ်ခုအဖြစ် ၎င်းတို့၏ဘေးဘက်သို့ မှတ်တမ်းတင်ပါ။

အဆင့် 3- လျှပ်စစ်ဝင်ပေါက်၊ ထွက်ပေါက်နှင့် ကွေ့ပတ်လောင်ကျွမ်းမှုကို ကုသပါ။

Electrical burns come in three distinct forms: true contact burns (entrance and exit wounds where current entered the skin and exited to ground), arc flash burns (caused by radiant plasma heat up to 19,000 °C / 35,000 °F when high voltage arcs across the air without entering the body), and secondary thermal flame burns (when sparks ignite the victim's shirt or trousers).

  1. Search for both the entrance AND exit wounds: Whenever you find a charred, depressed, leathery, or pale bullseye burn on a victim's hand or fingers, always check the soles of their feet, toes, opposite hand, thighs, and scalp for the corresponding exit wound, which frequently looks exploded outward.
  2. Cool external burns with cool running water for 20 minutes: Once the victim is completely clear of all electrical sources and breathing stably, flush thermal and contact burns gently with cool running tap water (around 15 °C / 59 °F) for 20 minutes. Do not delay CPR to cool burns, and stop cooling if the patient begins shivering (hypothermia).
  3. Remove constricting jewelry and watches immediately: Deep electrical current causes massive, rapid fluid swelling (edema) along the entire arm or leg within minutes. Slide off all rings, bracelets, watches, and tight boots immediately before the swelling traps them and cuts off blood flow.
  4. Never apply ice, butter, ointments, or tight circumferential wraps: Cover the cooled entrance and exit wounds loosely with sterile non-adherent gauze or a clean sheet of household plastic cling film laid lengthways over the limb (never wrapped tightly around the limb like a tourniquet).

Step 4: Treat for hypovolemic shock

Deep internal electrical burns pull massive volumes of plasma fluid out of the bloodstream into damaged muscle compartments, triggering rapid hypovolemic shock:

  • Keep the conscious, breathing patient lying flat and cover them with a light blanket to conserve core body heat.
  • Do not give the victim anything to eat or drink (no water, coffee, or pain pills), because patients with moderate-to-severe electrical injuries often require emergency general anesthesia in the operating room for surgical burn debridement or fasciotomy within hours of arrival.

The "iceberg effect": why every electrical shock requires hospital evaluation

The single greatest medical danger after surviving the initial shock is the iceberg effect: visible surface skin burns represent less than 5 to 10 percent of the total tissue destruction hiding inside the body.

    THE ELECTRICAL INJURY "ICEBERG EFFECT"

        [ Tiny Pinpoint Skin Entrance Burn ]   <-- Visible Surface (5%)
    ============================================   Skin Line
       /                                    \
      /   1. Bone heats to extreme temps     \
     /    2. Deep periosteal muscle cooks     \ <-- Hidden Internal
    /     3. Swelling inside rigid fascia      \    Destruction (95%)
   /         causes Compartment Syndrome        \
  /       4. Dead muscle releases Myoglobin      \
 /           causing Acute Kidney Failure         \
+--------------------------------------------------+

1. Deep muscle necrosis along bone ("Inside-Out Cooking")

Why can an electrician have only a 5-millimeter (0.2-inch) blister on their palm and yet lose their entire forearm 48 hours later?

  • Inside an arm or leg, compact bone has the highest electrical resistance of any human tissue (roughly 900 ohms-cm, compared to 70 ohms-cm for blood and nerves and 150 ohms-cm for muscle).
  • By Joule's Law (\(Q = I2 R t\)), as electrical current travels up the arm, the central bone acts like the heating element inside a toaster, heating to extreme temperatures and cooking the deep skeletal muscles attached directly to the bone from the inside out.
  • The overlying skin, cooled by room air, may look completely pink and unharmed while the deep flexor compartment beneath it is coagulated and necrotic.

2. Acute compartment syndrome (Surgical emergency)

Skeletal muscles in the forearms and lower legs are encased inside tough, unyielding fibrous sleeves called fascia.

  • As deep electrically burned muscle swells with edema fluid, the pressure inside that closed fascial sleeve skyrockets past 30 mmHg, crushing the arteries and nerves running through the limb (acute compartment syndrome).
  • Warning signs (The 6 Ps): Excruciating deep Pain out of proportion to the tiny skin burn (especially dramatic pain when the fingers or toes are passively stretched), Paresthesia (pins-and-needles numbness in the fingers/toes), Pallor (pale or mottled digits), Paralysis (weakness moving the hand/foot), Poikilothermia (limb feels cold), and Pulselessness (a late sign).
  • If the patient is not at a hospital where trauma surgeons can perform an immediate decompressive fasciotomy (making long surgical incisions to release the pressure), the entire hand, arm, or leg can die within 4 to 6 hours.

3. Rhabdomyolysis (Myoglobinuria) and acute kidney failure

When electrical current bursts millions of skeletal muscle cells, two toxic intracellular substances flood into the bloodstream:

  • Potassium (Hyperkalemia): Massive release of potassium from dead muscle cells spikes blood potassium levels, which can trigger lethal secondary cardiac arrest hours after the initial shock.
  • Myoglobin (Rhabdomyolysis): Myoglobin is a heavy iron-containing oxygen-binding protein inside muscle fibers. When dumped into the bloodstream, myoglobin filters into the kidneys and precipitates as thick, dark sludgy casts that clog the microscopic renal tubules, causing acute kidney failure (acute tubular necrosis).
  • လက်ဖက်ရောင် သို့မဟုတ် ကိုလာရောင် ဆီးရောင်သတိပေး လက္ခဏာ- လျှပ်စစ်ရှော့ခ် ခံစားရသူတစ်ဦးသည် **ပန်းရောင်၊ အနီ၊ အညိုရင့်ရောင်၊ လက်ဖက်ခြောက်ရောင် သို့မဟုတ် ကိုလာရောင် ညိုမည်းသော ဆီးသွားပါက ပြင်းထန်သော rhabdomyolysis ခံစားရပြီး အရေးပေါ် အကြောပြန်သွင်းသည့် အရည်ကို ချက်ချင်း ခွဲစိတ်ကုသရန် လိုအပ်ပါသည်။

4. Pediatric oral commissure (Electrical cord bite) ပူလောင်ခြင်း။

ကလေးငယ်များသည် ပါးစပ်ထောင့်တွင် လျှပ်စစ်ဓာတ်အားသွင်းကြိုးများ သို့မဟုတ် အားသွင်းကြိုးများကို ရံဖန်ရံခါ ဝါးစားကြသည်။ ပါးစပ်လျှပ်စစ်မီးလောင်သည့် ကလေးတိုင်းကို ဆေးရုံတွင် အကဲဖြတ်ရပါမည်။ အကြမ်းဖျင်း ** ဒဏ်ရာပြီးနောက် 5 မှ 14 ရက်အကြာ ** တွင်သေဆုံးနေသောမီးခိုးရောင်အနာအဂါးများထွက်ပြီး labial artery သို့တိုက်စားနိုင်ပြီးရုတ်တရက်နှုတ်ခမ်းသွေးလွှတ်ကြောများသွေးထွက်စေသည်။ ရက်အတန်ကြာမှ သွေးထွက်တာများလာပါက သန့်ရှင်းသော ပိတ်စကို အသုံးပြု၍ သင့်လက်မ (ပါးစပ်အတွင်း) နှင့် လက်ညိုးကြား နှုတ်ခမ်းကို တင်းတင်းကျပ်ကျပ်ညှပ်ကာ အရေးပေါ်ခန်းသို့ သွားရန်။

အရေးပေါ်ဌာနအကဲဖြတ်ခြင်းနှင့် ECG စောင့်ကြည့်ခြင်းအတွက်မဖြစ်မနေသတ်မှတ်ချက်များ

ပင်မဝါယာကြိုးများ၊ ကိရိယာများ သို့မဟုတ် လျှပ်စီးကြောင်းများမှ တကယ့်လျှပ်စစ်ရှော့ခ်ကို ခံစားရသူတိုင်းကို သမားတော်မှ အကဲဖြတ်သင့်သည်။ အရေးပေါ်ဌာန သယ်ယူပို့ဆောင်ရေး နှင့် 12-ခဲဓာတ်မှန်ရိုက်ခြင်း (ECG) စောင့်ကြည့်ခြင်း သည် အောက်ပါတို့မှ တစ်ခုခုရှိနေပါက မဖြစ်မနေလိုအပ်သည်-

  • ** မြင့်မားသောဗို့အား (> 1,000 V)** သို့မဟုတ် လျှပ်စီး၊ သို့မဟုတ် သတိလစ်ခြင်း၊ စိတ်ရှုပ်ထွေးခြင်း သို့မဟုတ် သတိမေ့ခြင်းတစ်ခုခုနှင့် ဆက်သွယ်ပါ။
  • အိမ်သုံးဝါယာကြိုးပေါ်တွင် **လက်မှိတ် သို့မဟုတ် လက်မှခြေအထိ) သို့မဟုတ် “လက်မလွှတ်ရ” tetanic သော့ခတ်ခြင်း မည်သည်မဆို ရှည်လျားသည်။
  • ရင်ဘတ်အောင့်ခြင်း၊ နှလုံးတုန်ခြင်း၊ အသက်ရှုမဝခြင်း၊ ဝင်ပေါက် သို့မဟုတ် ထွက်ပေါက်များ လောင်ကျွမ်းခြင်း၊ ကြွက်သားများ နာကျင်ခြင်း၊ သို့မဟုတ် လက်ဖက်ရည်ညိုရောင် ဆီးသွားခြင်း။
  • ကိုယ်ဝန်ရှိခြင်း (သန္ဓေသားကို ချက်ချင်းစောင့်ကြည့်ရန် လိုအပ်သည်) သို့မဟုတ် နဂိုရှိပြီးသား နှလုံးအခြေအနေများ။

Tip

ကြက်ခြေနီ၊ စိန့်ဂျွန်လူနာတင်ယာဉ်၊ သို့မဟုတ် အမေရိကန်နှလုံးအဖွဲ့အစည်းထံမှ လက်ကမ်းထားသော CPR၊ AED နှင့် ရှေးဦးသူနာပြုစုနည်းလက်မှတ်သင်တန်းကို သင်ယူရန် စဉ်းစားပါ။ ရင်ဘတ်ဖိခြင်းကို မည်ကဲ့သို့လုပ်ဆောင်ရမည်ကို သိရှိခြင်းနှင့် လျှပ်စစ်ထိတွေ့မှုကို ချိုးဖျက်ပြီးနောက် AED ကို ချက်ချင်းလည်ပတ်စေခြင်းဖြင့် သားကောင်၏ အသက်ရှင်နိုင်ခြေကို သုံးဆတိုးစေသည်။

မေးလေ့ရှိသောမေးခွန်းများ

ယခုအချိန်တွင် လုံးဝနေကောင်းနေပါက လျှပ်စစ်ရှော့ခ်ကြောင့် နှလုံးဖောက်ခြင်း သို့မဟုတ် နှလုံးရပ်ခြင်း နှောင့်နှေးခြင်းတို့ကို ဖြစ်စေနိုင်ပါသလား။

အကယ်၍ သင်သည် ဗို့အားမြင့် ရှော့တိုက်ခြင်း (1,000 ဗို့ထက်) ခေတ္တမျှပင် သတိလစ်သွားခြင်း၊ ကြွက်သားများ နာကျင်ခြင်း သို့မဟုတ် ပူလောင်ခြင်း သို့မဟုတ် ရင်ဘတ်အောင့်ခြင်း သို့မဟုတ် ရင်တုန်ခြင်းတို့ကို ခံစားရပါက၊ နှလုံးခုန်နှုန်း နှောင့်နှေးခြင်း သို့မဟုတ် ပိုတက်စီယမ် ယိုစိမ့်မှုကြောင့် ပျက်စီးသွားသော ကြွက်သားဆဲလ်များမှ ECG စောင့်ကြည့်ရန် နာရီပိုင်းကြာပြီးနောက် နာရီပိုင်းအကြာတွင် ဖြစ်ပွားနိုင်သည်။ ဗို့အားနိမ့်အိမ်တွင်းရှော့တိုက်ခြင်း (120 V မှ 240 V) တွင် သင်သတိမေ့ပျောက်ပြီး ကောင်းကောင်းမခံစားရသည့်အတွက်၊ ပုံမှန် 12-lead electrocardiogram (ECG) ဖြင့် အမြန်စစ်ဆေးခြင်းသည် နှလုံးခုန်နှုန်းနှောင့်နှေးခြင်းအန္တရာယ်ကို တားဆီးပေးပါသည်။

အိမ်သုံး Alternating Current (AC) သည် တူညီသောဗို့အား Direct Current (DC) ထက် အဘယ်ကြောင့် ပို၍ အန္တရာယ်ရှိသနည်း။

အိမ်သူအိမ်သားများ၏ လှည့်ပတ်နေသော လက်ရှိလည်ပတ်များသည် တစ်စက္ကန့်လျှင် 50 သို့မဟုတ် 60 ကြိမ်နှုန်း (50/60 Hz) ဖြင့် အပြန်ပြန်အလှန်လှန် လှုပ်ခတ်နေသော လူ့အရိုးစုကြွက်သားမျှင်များကို စဉ်ဆက်မပြတ် သော့ခတ်ထားသော tetanic spasm ("မလွှတ်ရ" ဖြစ်စဉ်) အဖြစ်သို့ လှုံ့ဆော်ပေးသည်။ လက်ဖျံကြွက်သားများသည် extensor ကြွက်သားများထက် ပိုမိုသန်မာသောကြောင့်၊ သားကောင်၏လက်သည် တိုက်ရိုက်ဝိုင်ယာကြိုးတစ်ဝိုက်ကို တင်းတင်းကြပ်ကြပ် ချည်နှောင်ထားပြီး၊ လက်ရှိစီးဆင်းမှုနှင့် အတွင်းတစ်ရှူးချက်ပြုတ်မှုကြာချိန်ကို တိုးမြင့်စေသည်။ ထို့အပြင်၊ 50/60 Hz AC သည် DC ထက် သုံးဆမှ ငါးဆနိမ့်သော လက်ရှိ ventricular fibrillation ကို ဖြစ်ပေါ်စေပြီး နှလုံး၏ ထိခိုက်လွယ်သော repolarization ပြတင်းပေါက်ကို ထပ်ခါတလဲလဲ တိုက်သည်။

သစ်သားတံမြက်စည်း သို့မဟုတ် သစ်ကိုင်းခြောက်ကို အသုံးပြု၍ တစ်စုံတစ်ဦးအား အပေါ်မှပြုတ်ကျနေသော ဓာတ်အားလိုင်းကို တွန်းထုတ်ရန် အန္တရာယ်ကင်းပါသလား။

မဟုတ်ပါ၊ သစ်သားတံမြက်စည်း၊ သစ်ပင်ကိုင်း၊ ပလပ်စတစ်ပိုက် သို့မဟုတ် ရာဘာလက်အိတ်ကို အသုံးပြု၍ အထက်ပါဝါလိုင်း သို့မဟုတ် ဗို့အားမြင့်ဝါယာကြိုး (> 1,000 ဗို့) ကို ရွှေ့ရန် ဘယ်သောအခါမှ မကြိုးစားပါနှင့်။ အိမ်သုံးလျှပ်ကူးပစ္စည်းမဟုတ်သောကိရိယာများသည် ဗို့အားနိမ့်အိမ်သုံးလျှပ်စီးကြောင်း (110 V မှ 240 V) ကိုသာ အကာအကွယ်ပေးသည်။ ဖြန့်ဖြူးသည့်ဗို့အား 4,000 မှ 35,000 ဗို့တွင်၊ လျှပ်စစ်ဓာတ်အား လေထဲသို့ စိုက်ထုတ်သွားကာ သစ်သား သို့မဟုတ် ပလပ်စတစ်ရှိ အဏုကြည့်အစိုဓာတ်နှင့် အစေးလမ်းကြောင်းများကို ဆင်းသက်ကာ ကယ်တင်သူထံ တိုက်ရိုက်ရောက်ရှိကာ လူနှစ်ဦးစလုံး သေဆုံးခဲ့ရသည်။ 10 မှ 20 မီတာ (33 မှ 65 ပေ) အကွာအဝေးတွင် အမြဲနေ၍ လျှပ်စစ်စွမ်းအင်သုံးကုမ္ပဏီမှ လိုင်းအားလျော့သွားစေရန် စောင့်ပါ။

ဝိုင်ယာကြိုးကိုမထိရင်တောင် ပြုတ်ကျနေတဲ့ ဓာတ်အားလိုင်းအနီးမှာ ခြေနှစ်ချောင်းစလုံးကို တွဲပြီး ခုန်ကူးရမှာလဲ၊

ဗို့အားမြင့်ဝါယာကြိုးသည် မြေကြီးနှင့်ထိသောအခါ၊ လျှပ်စစ်ဓာတ်သည် ရေကန်ထဲတွင် လှိုင်းဂယက်များကဲ့သို့ ဗို့အားလျော့ကျနေသော ဗဟိုချက်ကွင်းများအဖြစ် မြေဆီလွှာအတွင်းမှ လျှပ်စစ်ဓာတ်များ ထွက်လာသည်။ ပုံမှန်အတိုင်း လမ်းလျှောက်ပါက၊ သင်၏ ရှေ့ခြေသည် မတူညီသော ဗို့အားတစ်ခု၏ ကွင်းတစ်ခုအား ထိသွားချိန်တွင် သင့်နောက်ခြေသည် ဗို့အားတစ်ခု၏ ကွင်းတစ်ခုပေါ်တွင် ကျရောက်နေသည်။ သင့်ခြေဖဝါးကြားရှိ ဗို့အားခြားနားချက် (ခြေလှမ်းအလားအလာ) သည် မြင့်မားသောလျှပ်စီးကြောင်းအား တွန်းအားပေးပြီး ခြေထောက်တစ်ဖက်၊ သင်၏ တင်ပါးဆုံတွင်းနှင့် နှလုံးမှတစ်ဆင့် နှင့် အခြားခြေထောက်တစ်ဖက်ကို အောက်သို့ တွန်းပို့ပေးပါသည်။ ခြေနှစ်ချောင်းစလုံးကို တင်းတင်းကြပ်ကြပ် ဖိထားပြီး တရှပ်ရှပ် သို့မဟုတ် ခုန်နေပါက ခြေနှစ်ချောင်းစလုံးသည် တူညီသောလျှပ်စစ်ဖြစ်နိုင်ခြေကို သေချာစေသောကြောင့် သင့်ခန္ဓာကိုယ်တစ်လျှောက်ပတ်လမ်းများ မဖြစ်ပေါ်စေပါ။

လျှပ်စစ်ရှော့တိုက်ခံရသူသည် ၎င်းတို့၏အရေပြားတွင် သေးငယ်သောအချက်များသာ မီးလောင်နေပါက အဘယ်ကြောင့် အရေးပေါ်ခန်းသို့ သွားရန်လိုအပ်သနည်း။

လျှပ်စစ်ထိခိုက်ဒဏ်ရာရမှုများ၏ ၉၅ ရာခိုင်နှုန်းသည် ခန္ဓာကိုယ်အတွင်းပိုင်းအထိ မမြင်နိုင်သော ရေခဲတောင်အကျိုးသက်ရောက်မှုနောက်ဆက်တွဲဖြစ်သည်။ အရိုးသည် မည်သည့်တစ်ရှူးများ၏လျှပ်စစ်ဓာတ်အား အမြင့်ဆုံးခံနိုင်ရည်ရှိသောကြောင့်၊ လက် သို့မဟုတ် ခြေထောက်မှတဆင့် စီးဆင်းနေသော စီးဆင်းမှုသည် အရိုးကို အပူချိန်လွန်ကဲစွာ အပူပေးကာ အရိုးအတွင်းပတ်ထားသော နက်ရှိုင်းသောကြွက်သားအလွှာများကို ချက်ပြုတ်စေပြီး အပြင်ဘက်အရေပြားကို ပုံမှန်နီးပါးမြင်စေသည်။ ဤနက်နဲသောကြွက်သားများ ပျက်စီးခြင်းသည် ခြေလက်အန္တရာယ်ဖြစ်စေနိုင်သော အစိတ်အပိုင်းလက္ခဏာစုကို လျင်မြန်စွာဖြစ်စေနိုင်ပြီး နာရီပိုင်းအတွင်း စူးရှသောကျောက်ကပ်ပျက်ကွက်မှုကို ဖြစ်စေသည့် ကြွက်သားပရိုတင်းများ (myoglobin) ကို ထုတ်ပေးနိုင်သည်။

အိမ်သုံးလျှပ်စစ်ရှော့တိုက်ခံရပါက ကိုယ်ဝန်ဆောင်မိခင်သည် မည်သို့လုပ်ဆောင်သင့်သနည်း။

အထူးသဖြင့် အိမ်တွင်းရှိ ပလပ်ပေါက်၊ စက်ကိရိယာ သို့မဟုတ် ကြိုးချို့ယွင်းနေသည့် ကိုယ်ဝန်ဆောင်မိခင်တစ်ဦးသည် အထူးသဖြင့် လက်ထဲသို့ လျှပ်စီးဝင်၍ ခြေထောက်များထိသွားပါက အရေးပေါ်ဌာန သို့မဟုတ် သားဖွားမီးယပ်အထူးကုဌာနသို့ ချက်ချင်းသွားသင့်ပြီး အရေပြားတွင် မီးလောင်ဒဏ်ရာများ လုံးဝမခံစားရပါက၊ Amniotic fluid နှင့် သန္ဓေသား၏ သွေးလည်ပတ်မှုသည် အလွန်နည်းသော လျှပ်စစ်ခံနိုင်ရည်အား ပေးစွမ်းနိုင်သောကြောင့် မိခင်၏လက်ကို တုန်လှုပ်သွားစေမည့် အသေးစားလျှပ်စီးကြောင်းသည် သားအိမ်မှတဆင့် တိုက်ရိုက်ဖြတ်သန်းနိုင်ပြီး ကလေး၏ နှလုံးခုန်နှုန်း သို့မဟုတ် အချင်းကို ထိခိုက်စေပါသည်။

ဆက်စပ်လမ်းညွှန်များ

အရင်းအမြစ်များကို စစ်ဆေးခဲ့သည်။

  • American Heart Association (AHA, United States) နှင့် International Liaison Committee on Resuscitation (ILCOR)- နှလုံးသွေးကြောဆိုင်ရာ ကယ်ဆယ်ရေးနှင့် အရေးပေါ် နှလုံးသွေးကြောဆိုင်ရာ စောင့်ရှောက်မှုအတွက် လမ်းညွှန်ချက်များ (အသက်ရှင်ခြင်း၏ အထူးအခြေအနေ- လျှပ်စစ်ဒဏ်ရာနှင့် လျှပ်စီးကြောင်းများ)
  • European Resuscitation Council (ERC)- အထူးအခြေအနေများတွင် နှလုံးဖမ်းဆီးခြင်းဆိုင်ရာ လမ်းညွှန်ချက်များ၊ လျှပ်စစ်ဓာတ်အားနှင့် မိုးကြိုးပစ်ခြင်း
  • လုပ်ငန်းခွင်ဘေးကင်းရေးနှင့် ကျန်းမာရေး စီမံခန့်ခွဲမှု (OSHA၊ United States) နှင့် လုပ်ငန်းခွင်ဘေးကင်းရေးနှင့် ကျန်းမာရေးဆိုင်ရာ အမျိုးသားအင်စတီကျု (NIOSH / CDC၊ United States)- လျှပ်စစ်အန္တရာယ်ကင်းရှင်းရေး၊ အဆင့်အလားအလာနှင့် Arc Flash Trauma လမ်းညွှန်ချက်များ
  • American Burn Association (ABA၊ United States) - Advanced Burn Life Support (ABLS) လျှပ်စစ်နှင့် လျှပ်စီးဒဏ်ရာများအတွက် ဆေးခန်းဆိုင်ရာ လက်တွေ့လမ်းညွှန်ချက်များ
  • အမျိုးသားကျန်းမာရေးဝန်ဆောင်မှု (NHS၊ United Kingdom) နှင့် St John လူနာတင်ယာဉ် (ယူနိုက်တက်ကင်းဒမ်း)- ဗို့အားမြင့်နှင့် ဗို့အားနိမ့်လျှပ်စစ် Shock အတွက် ရှေးဦးသူနာပြုနည်းများ