Electric shock first aid: what to do and what to avoid¶
Tísňová čísla se v jednotlivých zemích liší. Tato stránka používá 911, číslo pro Spojené státy a Kanadu. Mnoho dalších zemí používá číslo 112, 999 nebo jiné číslo. Najděte číslo pro vaši zemi.
Electrical injuries are among the most deceptive and complex emergencies in trauma medicine. While the visible skin contact points may appear as minor, pinpoint surface burns, electrical current passing through the human body converts into intense internal thermal energy along deep anatomical pathways. Within milliseconds, household or industrial current can induce involuntary muscle paralysis that locks the victim onto the live conductor, trigger lethal ventricular fibrillation or respiratory arrest, coagulate deep vascular networks, cook periosteal skeletal muscle against heated bone, and fracture the spine through violent tetanic contractions.
Absolutně prvním pravidlem jakékoli elektrické nouze je bezpečnost záchranářů: dotek osoby, která zůstává v kontaktu s pod napětím, z vás udělá okamžitou sekundární oběť. Vědět, jak izolovat domácí a komerční elektřinu, oddělit nízkonapěťovou oběť pomocí suchých nevodivých izolátorů, uniknout koncentrickým prstencům zemního napětí (krokový potenciál) spadlého vysokonapěťového vedení, zahájit okamžitou kardiopulmonální resuscitaci (KPR) a rozpoznat opožděné vnitřní komplikace, jako je rhabdomyolýza a kompartment syndrom, zachraňuje životy.
Udělejte to teď¶
- Nedotýkejte se oběti holýma rukama, oděvem nebo jakýmkoliv kovovým nebo mokrým předmětem, když se stále dotýká elektrického zdroje. Lidské tělo je elektrolytický vodič; uchopení elektrizované osoby přenese živý proud přímo přes vaše vlastní srdce a nervový systém.
- Okamžitě zavolejte záchrannou službu a uveďte, že došlo k úrazu elektrickým proudem. Zavolejte na místní tísňové číslo (911 ve Spojených státech a Kanadě, 112 v celé Evropské unii, 999 ve Spojeném království) nebo zkontrolujte tísňová číslaa požádejte záchranáře i elektrárenskou společnost, pokud jde o vedení vysokého napětí.
- Shut off the electrical power source immediately if it is low-voltage household or commercial power (under 1,000 volts). Flip the main circuit breaker switch at the electrical service panel, unscrew the fuse, switch off the wall socket switch (where equipped), or pull the insulated rubber plug from the outlet if the cord is undamaged and away from water.
- Zůstaňte alespoň 10 až 20 metrů (33 až 65 stop) vzadu, pokud je zdrojem vysoké napětí (přes 1000 voltů), spadlé nadzemní elektrické vedení nebo blesk. Nikdy se nepokoušejte vypáčit vysokonapěťový drát z někoho koštětem nebo dřevěnou větví, protože vysokonapěťová elektřina prochází vzduchem a vede dolů po nevodivých sloupech; počkejte, dokud technici rozvodné sítě nepotvrdí, že je síť bez napětí a uzemněna.
- Pokud nelze nízkonapěťovou elektřinu v domácnosti okamžitě vypnout, odtlačte postiženého nebo drát pryč pomocí zcela suchého, nevodivého předmětu. Postavte se na suchý izolační povrch (jako je pryžová rohožka, suchá dřevěná deska nebo tlustý stoh novin) a použijte suchou dřevěnou násadu od koštěte, tyč ze skleněného vlákna, suchou PVC trubku nebo smyčkové suché bavlněné lano, abyste přerušili kontakt.
- Check responsiveness and breathing the instant the victim is clear of the electricity, and start CPR immediately if needed. If the person is unresponsive and not breathing normally (or only taking irregular agonal gasps), begin cardiopulmonary resuscitation (CPR) at 100 to 120 compressions per minute and attach an Automated External Defibrillator (AED) as soon as one arrives; if they are breathing, cool any visible burns with cool running water for 20 minutes and keep their neck and spine still.
flowchart TD
Start["Person in Contact with Electrical Source"] --> HVCheck{"Is it High Voltage (>1,000 V), a downed power line, or wet environment?"}
HVCheck -->|"Yes: High Voltage or Downed Line"| HVProtocol["Keep 10 to 20 meters (33 to 65 feet) away; NEVER approach or use poles"]
HVProtocol --> CallUtil["Call 911 / 112 / 999 and electric utility; shuffle with feet together if inside zone"]
HVCheck -->|"No: Low Voltage Household (110 V to 240 V)"| CutPower{"Can you safely shut off the breaker or unplug the cord?"}
CutPower -->|"Ano"| PowerOff["Flip main circuit breaker to Off or pull insulated plug"]
CutPower -->|"Ne"| Insulate["Stand on dry rubber or wood; push wire or victim away with dry wood or plastic tool"]
PowerOff --> Assess["Victim Free of Current: Check responsiveness and breathing for 10 seconds"]
Insulate --> Assess
Assess --> BreathCheck{"Is the victim responsive and breathing normally?"}
BreathCheck -->|"No (Unresponsive / Agonal gasps)"| StartCPR["Start CPR (30:2 or Hands-Only) at 100 to 120 bpm and apply AED immediately"]
BreathCheck -->|"Yes (Breathing normally)"| TraumaCare["Immobilize spine if fallen, cool burns with cool running water for 20 min, transport to ER"]
Physics and pathophysiology of electrical trauma¶
When an electrical circuit forms across the human body, the severity of cellular and organ destruction is governed by six physical variables summarized by Ohm's Law (\(I = V / R\), where current equals voltage divided by resistance) and Joule's First Law of Heating (\(Q = I^2 \times R \times t\), where thermal heat generated equals the square of the current multiplied by tissue resistance and contact duration):
- Amperage (Current intensity in milliamperes, mA): Amperage is the primary physiological killer, determined by the driving voltage divided by skin and internal tissue resistance.
- Voltage (Electrical potential in volts, V): Divided clinically into low voltage (under 1,000 volts, such as 120 V North American mains, 230 V European/UK/Australian mains, and 400 V three-phase commercial wiring) and high voltage (1,000 volts and above, such as overhead utility distribution lines carrying 4,160 V to 34,500 V and transmission towers carrying 115,000 V to 765,000 V).
- Resistance (Impedance in ohms, \(\Omega\)): Dry, calloused human palms offer high resistance (up to 40,000 to 100,000 ohms), which limits current flow. However, wet skin, sweaty skin, immersed skin in a bathtub, or broken skin drops epidermal resistance down to 500 to 1,000 ohms. At 1,000 ohms of wet skin resistance, touching a standard 120-volt or 230-volt bathroom appliance delivers 120 to 230 milliamperes directly into the bloodstream, which is more than enough to trigger instant cardiac arrest.
- Typ proudu: Střídavý proud (AC) versus stejnosměrný proud (DC).
- Anatomická dráha (transtorakální vs vertikální): Proud se šíří cestou nejmenšího elektrického odporu (krevní cévy, nervy a svaly) od vstupního kontaktního bodu do bodu výstupu ze země:
- Z ruky do ruky (horizontální transtorakální dráha): Proud vstupuje do jedné ruky, prochází přímo přes mediastinum a srdce a vystupuje z opačné ruky. Tato cesta nese nejvyšší úmrtnost (~60 procent u vysokonapěťových kontaktů) v důsledku přímé fibrilace myokardu.
- Od ruky k noze (vertikální dráha): Proud se šíří z horní končetiny přes hrudník, břišní orgány a nohu k podlaze.
- Z nohy do nohy (potenciální dráha kroku nebo kroku): Proud vstupuje do jedné nohy, prochází pánví a vystupuje druhou nohou.
- Doba kontaktu (\(t\)): Čím déle zůstane tělo připojeno k drátu, tím více tepelného tepla se akumuluje uvnitř hlubokých tkání a kůže se rozpadne, odpor dále klesá a zrychluje se přítok proudu.
Fyziologické účinky střídavého proudu 50/60 Hz v miliampérech¶
| Intenzita proudu (mA, 1sekundový kontakt) | Fyziologický účinek na lidské tělo | Klinický výsledek |
|---|---|---|
| 1 až 3 mA | Práh smyslového vnímání | Mírné brnění na konečcích prstů; žádné poškození tkáně |
| 5 až 10 mA | Bolestivý smyslový šok | Ostrá bolest; normální dospělý může stále dobrovolně uvolnit své sevření („pouštěcí“ proud) |
| 10 až 20 mA | Práh „Let-Go“ (Flexor Tetany) | Nedobrovolná tetanická kontrakce svalů flexorů předloktí pevně uzamkne ruku kolem drátu; oběť nemůže pustit |
| 20 až 50 mA | Hrudní a brániční tetanie | Nepřetržité ochrnutí bránice a mezižeberních dýchacích svalů; způsobuje zástavu dechu a udušení, pokud kontakt pokračuje |
| 50 až 100 mA | Práh ventrikulární fibrilace (V-Fib) | Elektrický proud udeří během zranitelného okna repolarizace srdeční T-vlny a uvrhne srdce do chaotické fibrilace |
| 1 000 až 4 000 mA (1 až 4 A) | Trvalá kontrakce myokardu (asystolie) a hluboké tepelné popáleniny | Úplné zastavení srdečního svalu v kombinaci s masivním vařením hlubokých vnitřních tkání |
Střídavý proud (AC) versus stejnosměrný proud (DC)¶
| Klinický a fyzikální rys | Střídavý proud (AC: 50 Hz / 60 Hz) | Stejnosměrný proud (DC) |
|---|---|---|
| Obvyklé zdroje ze skutečného světa | Domácí zásuvky (120 V / 230 V), kuchyňské spotřebiče, elektrické nářadí, komerční vzduchotechnika, venkovní rozvody | Akumulátory pro automobily a elektromobily (12 V až 800 V), solární fotovoltaická pole, elektrifikované třetí kolejnice metra, obloukové svářečky, blesky |
| Reakce kosterního svalstva | Nepřetržité tetanické křeče (fenomén „No-Let-Go“): Protože proud obrátí směr 50 až 60krát za sekundu, svaly flexorů předloktí se nepřetržitě stahují a sevřou pěst oběti na živém drátu. | Jedna prudká balistická kontrakce: Vyvolává jedinou masivní svalovou křeč, která často odhodí oběť několik metrů dozadu od zdroje energie |
| Primární srdeční arytmie | Ventrikulární fibrilace (V-Fib): 3 až 5krát nebezpečnější než DC při nízkém napětí, protože cyklus 50/60 Hz opakovaně protíná zranitelnou fázi repolarizace srdce | Komorová asystolie (kardiální klid): Vysokonapěťový DC depolarizuje celý myokard najednou a úplně zastaví srdeční tep |
| Profil souvisejícího traumatu | Prodloužená doba kontaktu vedoucí k hluboké vnitřní tepelné nekróze, respirační zadušení a lokálním popáleninám na vstupu/výstupu v celé tloušťce | Kratší doba kontaktu, ale vysoká míra tupého ortopedického traumatu (zlomeniny lebky, zlomeniny krční páteře, ruptura sleziny, zlomeniny dlouhých kostí) v důsledku vymrštění nebo pádu ze žebříku |
Bezpečné záchranné protokoly: přerušení elektrického kontaktu¶
Danger
Nikdy se nepřibližujte na vzdálenost do 10 metrů (33 stop) k spadlému nadzemnímu elektrickému vedení, transformátoru rozvodny, elektrifikované železniční koleji nebo jinému průmyslovému vysokonapěťovému zdroji překračujícímu 1 000 voltů a nikdy se nepokoušejte pohybovat vysokonapěťovým drátem dřevěným koštětem, větví stromu nebo plastovým nástrojem. Vysokonapěťová elektřina ionizuje vzduch, aby skákal (oblouk) přes otevřený prostor a putoval po povrchové vlhkosti dřeva nebo plastu přímo do vašeho těla.
1. Nízkonapěťová záchrana domácnosti a pracoviště (pod 1 000 voltů)¶
Když někoho šokuje 120V nebo 230V domácí spotřebič, prodlužovací kabel, elektrické nářadí nebo vadný vypínač:
- Nejprve vypněte napájení u zdroje (vždy nejbezpečnější metoda):
- Běžte k domácímu elektrickému rozvodnému panelu (pojistková skříňka nebo jistič) a přepněte Hlavní jistič do polohy Vypnuto nebo přepněte jistič konkrétní odbočky.
- Ve Spojeném království, Evropě a Austrálii mají nástěnné zásuvky individuální kolébkový vypínač; pokud je zásuvka suchá a můžete k ní dosáhnout, aniž byste se dotkli oběti nebo přístroje, vypněte zásuvku suchým nevodivým předmětem a vytáhněte zástrčku.
- Pokud oběť drží spotřebič ve vlhkém prostoru (podlaha v koupelně, zatopený sklep, terasa u bazénu nebo mokrý trávník), nikdy nevstupujte na mokrou podlahu ani se nedotýkejte kabelu zařízení. Vypínejte proud výhradně na hlavním domovním jisticím panelu, když stojíte na suché podlaze.
- Jak oddělit oběť, když je jistič nedosažitelný:
- Pokud se nemůžete dostat k jističi během několika sekund a oběť je uzamčena v tetanické křeči na suché podlaze v interiéru, musíte se izolovat od země i oběti:
- Krok A (izolujte si nohy): Postavte se na silný, zcela suchý, nevodivý materiál, jako je pryžová rohožka, pár suchých pracovních bot s pryžovou podrážkou, suché dřevěné prkénko nebo tlustý stoh suchých knih nebo složených suchých ručníků.
- Krok B (Výběr suchého nevodivého nástroje): Uchopte dlouhý předmět vyrobený z čistého izolačního materiálu: suchou dřevěnou násadu od koštěte, suchou dřevěnou židli, pevnou plastovou nebo PVC trubku, rukojeť nástroje ze skleněných vláken nebo suchou srolovanou bavlněnou přikrývku nebo suché nylonové lano omotané kolem suché končetiny nebo oděvu oběti.
- Krok C (Ověřte nulový obsah kovu nebo vlhkosti): Zajistěte, aby násada koštěte neměla kovovou závěsnou čepici, mokrou barvu nebo vlhkost a nikdy nechytejte oběť za holou kůži nebo vlhký, zpocený oděv.
- Krok D (Přerušení kontaktu jedním rozhodným tahem): Použijte dřevěnou tyč k odstrčení ruky oběti z drátu nebo sražení kabelu přístroje od oběti jediným pevným zatlačením, aby nespadla zpět na vodič pod napětím.
2. Havarijní stavy vysokého napětí, výpadky elektrického vedení a skokový potenciál¶
Když při bouřce nebo autonehodě praskne nadzemní vedení (přenášející 4 000 až 35 000+ voltů) a spadne na zem, vozovku, plot nebo strom, kolem kontaktního bodu se okamžitě vytvoří dvě neviditelná fyzická nebezpečí: elektrický oblouk a potenciál zemního stupně (spád napětí).
Pochopení potenciálu kroku a potenciálu dotyku¶
Když vysokonapěťový kabel pod napětím leží na zemi, ne vždy vypne jistič rozvodny, zvláště pokud půda, suchý asfalt nebo větve stromu nabízejí střední impedanci. Místo toho proudí tisíce voltů elektřiny nepřetržitě do země a šíří se ven v soustředných kruhových prstencích s klesajícím napětím, přesně jako vlnky, které se šíří ven, když spadne kámen do rybníka:
-Přímým dotykem drátu na zemi může být půda na 15 000 voltů. - Ve vzdálenosti 2 metrů (6,5 stopy) může být půda na 10 000 voltů. - Ve vzdálenosti 4 metrů (13 stop) může být půda na 6 000 voltů. - Ve vzdálenosti 10 metrů (33 stop) půda klesá na 0 voltů.
Pokud zachránce běží nebo jde normálním krokem 0,8 metru (2,5 stopy) do této soustředné zóny, jeho přední noha dosedne na 8 000 voltový prstenec, zatímco jeho zadní noha spočívá na 10 000 voltovém prstenci. Tento 2 000 voltový rozdíl mezi jejich dvěma chodidly (krokový potenciál) okamžitě volí nízkoodporové lidské tělo před vysokoodolnou špínou: proud vystřelí nahoru jednou nohou, skrz pánevní orgány a srdce, a dolů druhou nohou, způsobí okamžitý tetanický kolaps na zem, kde nyní horizontální tělo překlene ještě větší napěťovou mezeru (potenciál mostu), což se rychle ukáže jako fatální.
Podobně potenciál dotyku nastane, když člověk stojí na zemi a dotkne se kovového plotu z drátěného pletiva, kovového zábradlí nebo karoserie vozidla, které se dotýká strženého elektrického vedení stovky metrů po ulici.
Jak uniknout ze sestřelené zóny elektrického vedení (Shuffle nebo Bunny-Hop)¶
Pokud si náhle uvědomíte, že stojíte do 10 až 20 metrů (33 až 65 stop) od staženého elektrického vedení, nebo pokud cítíte mravenčení v nohách a chodidlech:
- Okamžitě zmrazte svůj krok: Nedělejte další krok chůze a nikdy neběhejte.
- Použijte metodu Two-Fot Shuffle:
- Stiskněte kotníky a vnitřní okraje obou bot pevně k sobě, aby se vaše chodidla dotýkala vedle sebe.
- Slowly shuffle backward or away from the downed wire by sliding one foot forward only a few centimeters along the ground so the heel of your leading foot never passes the toes of your trailing foot, keeping both soles in continuous contact with the same voltage ring.
- Or use the Two-Foot Bunny-Hop method:
- Přitiskněte kolena, kotníky a chodidla pevně k sobě, zkřížte ruce pevně na hrudi, abyste neztratili rovnováhu a dotkli se rukama země, a odskočte obouma nohama opouštět a přistávat na zemi ve stejný okamžik.
- Never hop on one foot (if you fall over, your outstretched body will span multiple voltage rings).
- Continue shuffling or hopping until you are at least 10 meters (33 feet) away on dry ground, or 20 meters (65 feet) away if the pavement or grass is wet.
3. Trapped inside a vehicle touching a downed power line¶
If a utility pole falls across your car or truck:
- Stay inside the vehicle: As long as the car is not on fire, the safest place is sitting calmly inside the cabin. The metal body of the car acts as a Faraday cage while the rubber tires provide partial insulation, routing electricity around the exterior skin. Do not touch the metal door frames, window cranks, or radio, and call 911, 112, or 999 on your mobile phone. Warn bystanders loudly through a cracked window to stay at least 15 meters (50 feet) back.
- Emergency jump-and-shuffle evacuation (ONLY if the vehicle catches fire):
- If smoke or flames break out in the engine bay or cabin, you must exit without ever touching the metal car and the ground at the same time (which would turn your body into a direct ground bridge):
- Open the car door wide, being careful not to touch the exterior painted metal panel.
- Stand up on the interior floorboard or plastic door sill, cross your arms tightly over your chest, and tuck your chin.
- Jump clear of the vehicle so that both feet leave the car before either foot touches the ground, and land with both feet pressed tightly together.
- Do not stumble backward and touch the car with your hand. Immediately shuffle or bunny-hop with both feet together for at least 15 meters (50 feet) before walking normally.
Step-by-step medical first aid once the victim is clear¶
Once the power is off or the victim has been safely separated from the conductor, electrical trauma requires a structured C-A-B-C-D-E trauma resuscitation approach because electrical shock simultaneously causes cardiac arrest, central respiratory paralysis, spinal fractures, and thermal burns.
Step 1: Assess responsiveness, breathing, and start CPR / AED¶
- Tap the victim's shoulders and shout to check responsiveness while scanning the chest for normal breathing for no more than 10 seconds.
- Why prolonged CPR is essential in electric shock and lightning:
- Unlike elderly victims of coronary artery blockages, victims of electric shock or lightning are often young with healthy hearts whose cardiac conduction system was momentarily scrambled into ventricular fibrillation (from AC) or asystole (from DC/lightning), or whose brainstem respiratory center was stunned into prolonged apnea (respiratory arrest).
- If an electrical victim's heart keeps beating (or restarts quickly) but their brainstem breathing center remains stunned, they will die of secondary hypoxic cardiac arrest within minutes unless someone gives them rescue breaths and chest compressions.
- Reverse triage in multi-casualty lightning or high-voltage strikes: Normally, in mass-casualty disasters, rescuers treat breathing victims first and pass over apneic/pulseless victims. In lightning or electrical strikes, the rule is reversed ("Resuscitate the dead"): victims who are groaning and moving have a beating heart and will likely survive, whereas the motionless, blue victim on the ground is in reversible ventricular fibrillation or brainstem respiratory arrest and can be saved with immediate CPR and AED defibrillation.
- Deliver high-quality CPR (30 compressions to 2 rescue breaths):
- Push hard and fast in the center of the chest at 100 to 120 compressions per minute to a depth of 5 to 6 centimeters (2.0 to 2.4 inches) in adults.
- Because respiratory paralysis is a hallmark of thoracic tetany and brainstem stunning, include 2 rescue breaths after every 30 compressions if you are able, using a jaw-thrust maneuver if a fall or spinal injury is suspected.
- Attach an Automated External Defibrillator (AED) as soon as it arrives. Ensure the victim's chest is wiped dry of water or sweat, and place the pads at least 2.5 centimeters (1 inch) away from any scorched entrance burn if possible so skin char does not impede shock delivery.
Step 2: Immobilize the cervical spine and check for blunt trauma¶
Never roll or yank an electrical shock victim upright without considering their spine:
- High-voltage shocks and DC jolts cause violent, simultaneous contraction of the powerful paraspinal muscles, which can cause compression fractures of the thoracic and lumbar vertebrae or posterior shoulder dislocations even if the victim never fell.
- Furthermore, electricians, roofers, and homeowners frequently suffer electric shocks while standing on ladders, scaffolding, or utility poles.
- Keep the victim lying flat on their back, manually stabilize their head and neck in a neutral inline position with both hands if they fell or were thrown, and check for life-threatening arterial krvácení. If the victim is unconscious, breathing normally, and starts vomiting, log-roll their entire body onto their side as a single rigid unit while keeping the head, neck, and torso aligned.
Step 3: Treat electrical entrance, exit, and arc burns¶
Electrical burns come in three distinct forms: true contact burns (entrance and exit wounds where current entered the skin and exited to ground), arc flash burns (caused by radiant plasma heat up to 19,000 °C / 35,000 °F when high voltage arcs across the air without entering the body), and secondary thermal flame burns (when sparks ignite the victim's shirt or trousers).
- Search for both the entrance AND exit wounds: Whenever you find a charred, depressed, leathery, or pale bullseye burn on a victim's hand or fingers, always check the soles of their feet, toes, opposite hand, thighs, and scalp for the corresponding exit wound, which frequently looks exploded outward.
- Cool external burns with cool running water for 20 minutes: Once the victim is completely clear of all electrical sources and breathing stably, flush thermal and contact burns gently with cool running tap water (around 15 °C / 59 °F) for 20 minutes. Do not delay CPR to cool burns, and stop cooling if the patient begins shivering (hypothermia).
- Remove constricting jewelry and watches immediately: Deep electrical current causes massive, rapid fluid swelling (edema) along the entire arm or leg within minutes. Slide off all rings, bracelets, watches, and tight boots immediately before the swelling traps them and cuts off blood flow.
- Never apply ice, butter, ointments, or tight circumferential wraps: Cover the cooled entrance and exit wounds loosely with sterile non-adherent gauze or a clean sheet of household plastic cling film laid lengthways over the limb (never wrapped tightly around the limb like a tourniquet).
Step 4: Treat for hypovolemic shock¶
Deep internal electrical burns pull massive volumes of plasma fluid out of the bloodstream into damaged muscle compartments, triggering rapid hypovolemic shock:
- Keep the conscious, breathing patient lying flat and cover them with a light blanket to conserve core body heat.
- Do not give the victim anything to eat or drink (no water, coffee, or pain pills), because patients with moderate-to-severe electrical injuries often require emergency general anesthesia in the operating room for surgical burn debridement or fasciotomy within hours of arrival.
The "iceberg effect": why every electrical shock requires hospital evaluation¶
The single greatest medical danger after surviving the initial shock is the iceberg effect: visible surface skin burns represent less than 5 to 10 percent of the total tissue destruction hiding inside the body.
THE ELECTRICAL INJURY "ICEBERG EFFECT"
[ Tiny Pinpoint Skin Entrance Burn ] <-- Visible Surface (5%)
============================================ Skin Line
/ \
/ 1. Bone heats to extreme temps \
/ 2. Deep periosteal muscle cooks \ <-- Hidden Internal
/ 3. Swelling inside rigid fascia \ Destruction (95%)
/ causes Compartment Syndrome \
/ 4. Dead muscle releases Myoglobin \
/ causing Acute Kidney Failure \
+--------------------------------------------------+
1. Deep muscle necrosis along bone ("Inside-Out Cooking")¶
Why can an electrician have only a 5-millimeter (0.2-inch) blister on their palm and yet lose their entire forearm 48 hours later?
- Inside an arm or leg, compact bone has the highest electrical resistance of any human tissue (roughly 900 ohms-cm, compared to 70 ohms-cm for blood and nerves and 150 ohms-cm for muscle).
- By Joule's Law (\(Q = I^2 R t\)), as electrical current travels up the arm, the central bone acts like the heating element inside a toaster, heating to extreme temperatures and cooking the deep skeletal muscles attached directly to the bone from the inside out.
- The overlying skin, cooled by room air, may look completely pink and unharmed while the deep flexor compartment beneath it is coagulated and necrotic.
2. Acute compartment syndrome (Surgical emergency)¶
Skeletal muscles in the forearms and lower legs are encased inside tough, unyielding fibrous sleeves called fascia.
- As deep electrically burned muscle swells with edema fluid, the pressure inside that closed fascial sleeve skyrockets past 30 mmHg, crushing the arteries and nerves running through the limb (acute compartment syndrome).
- Warning signs (The 6 Ps): Excruciating deep Pain out of proportion to the tiny skin burn (especially dramatic pain when the fingers or toes are passively stretched), Paresthesia (pins-and-needles numbness in the fingers/toes), Pallor (pale or mottled digits), Paralysis (weakness moving the hand/foot), Poikilothermia (limb feels cold), and Pulselessness (a late sign).
- If the patient is not at a hospital where trauma surgeons can perform an immediate decompressive fasciotomy (making long surgical incisions to release the pressure), the entire hand, arm, or leg can die within 4 to 6 hours.
3. Rhabdomyolysis (Myoglobinuria) and acute kidney failure¶
When electrical current bursts millions of skeletal muscle cells, two toxic intracellular substances flood into the bloodstream:
- Potassium (Hyperkalemia): Massive release of potassium from dead muscle cells spikes blood potassium levels, which can trigger lethal secondary cardiac arrest hours after the initial shock.
- Myoglobin (Rhabdomyolysis): Myoglobin is a heavy iron-containing oxygen-binding protein inside muscle fibers. When dumped into the bloodstream, myoglobin filters into the kidneys and precipitates as thick, dark sludgy casts that clog the microscopic renal tubules, causing acute kidney failure (acute tubular necrosis).
- The tea-colored or cola-colored urine warning sign: If anyone who suffered an electric shock passes urine that looks pink, red, reddish-brown, dark tea-colored, or dark cola-colored, they have severe rhabdomyolysis and require immediate emergency intravenous fluid resuscitation in a hospital burn/trauma unit.
4. Pediatric oral commissure (Electrical cord bite) burns¶
Toddlers occasionally chew on live extension cords or charger plugs, creating an electrical arc at the corner of the mouth. Every child with an oral electrical burn must be evaluated at a hospital. Roughly 5 to 14 days after the injury, the dead gray scab sloughs off and can erode into the labial artery, causing sudden arterial lip bleeding. If bleeding starts days later, pinch the lip firmly between your thumb (inside the mouth) and index finger (outside the lip) using clean gauze and go straight to the emergency room.
Mandatory criteria for emergency department evaluation and ECG monitoring¶
Every person who experiences a true electrical shock from mains wiring, tools, or lightning should be evaluated by a physician. Immediate Emergency Department transport and 12-lead electrocardiogram (ECG) monitoring are mandatory if any of the following are present:
- Contact with high voltage (>1,000 V) or lightning, or any loss of consciousness, confusion, or amnesia.
- Any transthoracic pathway (hand-to-hand or hand-to-foot) or prolonged "no-let-go" tetanic lock on a household wire.
- Chest pain, heart palpitations, shortness of breath, visible entrance or exit burns, deep muscle pain, or dark tea-colored urine.
- Pregnancy at any stage (requires immediate fetal monitoring) or pre-existing heart conditions.
Tip
Consider taking a hands-on CPR, AED, and first aid certification course from the Red Cross, St John Ambulance, or the American Heart Association. Knowing how to perform chest compressions and operate an AED immediately after breaking electrical contact doubles to triples a victim's chance of survival.
Často kladené otázky¶
Can an electric shock cause a heart attack or delayed cardiac arrest hours later if I feel completely fine right now?
If you experienced a high-voltage shock (over 1,000 volts), lost consciousness even briefly, have deep muscle pain or burns, or feel any chest pain or fluttering palpitations, delayed cardiac arrhythmias can occur hours later due to myocardial bruising or potassium leaking from damaged muscle cells, requiring 24-hour hospital ECG monitoring. For a brief low-voltage household shock (120 V to 240 V) where you never lost consciousness and feel well, a quick medical check with a normal 12-lead electrocardiogram (ECG) rules out delayed heart rhythm danger.
Why is household Alternating Current (AC) more dangerous than Direct Current (DC) at the same voltage?
Household alternating current oscillates back and forth at 50 or 60 cycles per second (50/60 Hz), which stimulates human skeletal muscle fibers into a continuous, locked tetanic spasm ("no-let-go" phenomenon). Because the forearm flexor muscles are stronger than the extensor muscles, the victim's hand clamps tightly around the live wire, vastly increasing the duration of current flow and internal tissue cooking. In addition, 50/60 Hz AC repeatedly strikes the heart's vulnerable repolarization window, triggering ventricular fibrillation at three to five times lower current than DC.
Is it safe to use a wooden broomstick or dry tree branch to push a downed overhead power line off someone?
No, never attempt to use a wooden broomstick, tree branch, plastic pipe, or rubber gloves to move an overhead power line or any high-voltage wire (>1,000 volts). Household non-conductive tools only insulate against low-voltage household current (110 V to 240 V). At distribution voltages of 4,000 to 35,000 volts, electricity arcs effortlessly through the air and travels down microscopic moisture and resin pathways in wood or plastic directly into the rescuer, killing both people. Always stay 10 to 20 meters (33 to 65 feet) away and wait for the electric utility company to de-energize the line.
Why do I have to shuffle or hop with both feet together near a downed power line even if I am not touching the wire?
When a live high-voltage wire touches the earth, electricity radiates outward through the soil in concentric rings of decreasing voltage, like ripples in a pond. If you walk normally, your front foot lands on a ring of one voltage while your back foot touches a ring of a different voltage. That voltage difference between your feet (step potential) forces high-amperage current to shoot up one leg, through your pelvis and heart, and down the other leg. Keeping both feet pressed tightly together and shuffling or hopping ensures both feet stay at the exact same electrical potential so no circuit forms through your body.
Why does an electrical shock victim need to go to the emergency room if their skin only has a tiny pinpoint burn?
Electrical injuries follow the "iceberg effect," where 95 percent of the damage occurs out of sight deep inside the body. Because bone has the highest electrical resistance of any tissue, current traveling through an arm or leg heats the bone to extreme temperatures, cooking the deep muscle layers wrapped around the bone while leaving the outer skin looking nearly normal. This deep muscle destruction can rapidly cause limb-threatening compartment syndrome and release muscle proteins (myoglobin) that cause acute kidney failure within hours.
Co by měla těhotná žena dělat, pokud utrpěla menší domácí elektrický šok?
Každá těhotná osoba, která dostane elektrický šok z domácí zásuvky, spotřebiče nebo vadné šňůry, zejména pokud se proud dostal do ruky a uzemnil nohy, by měla okamžitě jít na pohotovost nebo na porodnickou jednotku, i když se cítí zcela nezraněná a nemá žádné popáleniny na kůži. Plodová voda a fetální oběh nabízejí velmi nízký elektrický odpor, což znamená, že malý proud, který sotva brní matčinu ruku, může projít přímo dělohou a ovlivnit srdeční frekvenci dítěte nebo placentu.
Související průvodci¶
- Kardiopulmonální resuscitace (KPR) a AED
- Popáleniny: klasifikace a první pomoc
- Elektrický oheň a jiskry
- Bouřky a blesky bezpečnost
- Severe bleeding control
- Nouzová telefonní čísla podle zemí
Zdroje zkontrolovány¶
- American Heart Association (AHA, United States) and International Liaison Committee on Resuscitation (ILCOR): Guidelines for Cardiopulmonary Resuscitation and Emergency Cardiovascular Care (Special Circumstances of Resuscitation: Electrical Injury and Lightning)
- European Resuscitation Council (ERC): Guidelines on Cardiac Arrest in Special Circumstances , Electrocution and Lightning Strike
- Occupational Safety and Health Administration (OSHA, United States) and National Institute for Occupational Safety and Health (NIOSH / CDC, United States): Electrical Safety, Step Potential, and Arc Flash Trauma Directives
- American Burn Association (ABA, United States): Advanced Burn Life Support (ABLS) Clinical Practice Guidelines for Electrical and Lightning Injuries
- National Health Service (NHS, United Kingdom) and St John Ambulance (United Kingdom): First Aid Protocols for High-Voltage and Low-Voltage Electric Shock