Deskarga elektrikoa: zer egin eta zer saihestu¶
Emergency numbers differ by country. This page uses 911, the number for the United States and Canada. Many other countries use 112, 999, or another number. Find the number for your country.
Lesio elektrikoak trauma medikuntzako larrialdi engainagarri eta konplexuenetakoak dira. Azaleko ukipen-puntu ikusgaiak gainazaleko erredura txiki eta zehatz gisa ager daitezkeen arren, giza gorputza zeharkatzen duen korronte elektrikoa barne-energia termiko bizia bihurtzen da bide anatomiko sakonetan zehar. Milisegundoren buruan, etxeko edo industria-korronteak nahigabeko muskulu-paralisia eragin dezake, biktima zuzeneko eroalean blokeatzen duena, fibrilazio bentrikular hilgarria edo arnas geldialdia abiarazi, baskular-sare sakonak koagulatu, hezur-muskulu periostea hezur beroaren aurka egosi eta bizkarrezurra haustu egiten du uzkurdura tetaniko bortitzen bidez.
Edozein larrialdi elektrikoen erabateko lehen araua salbatzaileen segurtasuna da: energia iturri elektriko batekin kontaktuan jarraitzen duen pertsona bat ukitzeak berehalako bigarren mailako biktima bihurtzen zaitu. Etxeko eta merkataritzako energia isolatzen jakitea, tentsio baxuko biktima bat isolatzaile ez-eroale lehorrak erabiliz bereizten jakitea, eroritako goi-tentsioko linearen lur-tentsioko eraztun kontzentrikoetatik (urrats potentziala) ihes egin, berehalako bihotz-biriken suspertzea (CPR) abiarazi eta atzeratutako barne-konplikazioak antzematea, hala nola rabdomiolisi sindromea eta konpartimentuen bizi-bizitza salbatzea.
Egin hau orain¶
- Ez ukitu biktima esku hutsekin, arroparekin edo metal edo objektu bustiarekin oraindik iturri elektrikoa ukitzen ari diren bitartean. Giza gorputza eroale elektrolitikoa da; Pertsona elektrifikatu bat harrapatzea zuzeneko korrontea zuzenean zure bihotzaren eta nerbio sistemaren bidez transferitzen da.
- Deitu berehala larrialdi zerbitzuei eta adierazi lesio elektriko bat gertatu dela. Deitu zure tokiko larrialdi-zenbakira (911 Estatu Batuetan eta Kanadan, 112 Europar Batasunean, 999 Erresuma Batuan) edo egiaztatu larrialdi zenbakiak, eta eskatu bai paramedikuei bai elektrizitate konpainiari, goi-tentsioko lineak tartean badira.
- Itzali elektrizitate iturria berehala tentsio baxuko energia elektrikoa edo komertziala bada (1.000 voltiotik beherakoa). Itzali etengailu nagusia zerbitzu elektrikoko panelean, destornilatu fusiblea, itzali hormako entxufearen etengailua (horni dagoenean) edo atera gomazko entxufe isolatua entxufetik, kablea hondatuta ez badago eta uretatik urrun.
- Egon gutxienez 10 eta 20 metro (33 eta 65 oin) atzera, iturria tentsio handiko (1.000 voltiotik gorakoa), erortzen den aireko linea elektrikoa edo tximista bada. Ez saiatu inoiz tentsio altuko kable bat erratz-makila edo egurrezko adar bat duen norbaiti kentzen, tentsio handiko elektrizitatea airean zehar eroalea ez den arkua baita; itxaron zerbitzu-teknikariek sarea desaktibatuta dagoela eta lurrarekin konfirmatu arte.
- Etxeko tentsio baxuko elektrizitatea berehala itzali ezin bada, urrundu biktima edo kablea erabat lehorra, eroale ez den objektu bat erabiliz. Jarri isolatzaile lehor batean (adibidez, gomazko ate-zerbitzua, egurrezko taula lehorra edo egunkari-piloa) eta erabili egurrezko erratz helduleku lehor bat, beira-zuntzezko zutoina, PVC-ko tutu lehorra edo soka lehorra kontaktua apurtzeko.
- Egiaztatu erantzuna eta arnasa hartzen duen biktimak elektrizitaterik gabe geratzen den momentuan, eta hasi berehala RCP behar izanez gero. Pertsonak ez badu erantzuten eta arnasa normalean hartzen ez badu (edo agonal agonal irregularrak bakarrik hartzen), hasi bihotz-biriken suspertzea (CPR) minutuko 100 eta 120 konpresiotan eta erantsi Kanpoko Desfibriladore Automatizatua (AED) bat iritsi bezain laster; arnasten ari badira, hoztu ikusgai dagoen edozein erredurak 20 minutuz ur freskoarekin eta lepoa eta bizkarrezurra geldi mantendu.
flowchart TD
Start["Iturri elektrikoarekin kontaktuan dagoen pertsona"] --> HVCheck{"Tentsio handiko (>1.000 V), erortutako linea elektrikoa edo ingurune hezea al da?"}
HVCheck -->|"Bai: goi-tentsioa edo beheratutako linea"| HVProtocol["Mantendu 10 eta 20 metrora (33 eta 65 oin); INOIZ EZ hurbildu edo erabili zutoinak"]
HVProtocol --> CallUtil["Deitu 911 / 112 / 999 telefonora eta argindarra; nahastu oinak elkarrekin eremu barruan bada"]
HVCheck -->|"Ez: Behe Tentsioko Etxea (110 V-tik 240 V-ra)"| CutPower{"Etengailua segurtasunez itzal dezakezu edo kablea deskonektatu?"}
CutPower -->|"Bai"| PowerOff["Biratu etengailu nagusia Itzalira edo tira isolatutako entxufea"]
CutPower -->|"Ez"| Insulate["Zutitu goma edo egur lehorrean; urrundu alanbrea edo biktima egur lehorra edo plastikozko tresnarekin"]
PowerOff --> Assess["Korronterik gabeko biktima: Egiaztatu erantzuna eta arnasa 10 segundoz"]
Insulate --> Assess
Assess --> BreathCheck{"Biktimak erantzuten du eta arnasa normal hartzen du?"}
BreathCheck -->|"Ez (erantzuten ez dutenak/hasialdi agonalak)"| StartCPR["Hasi CPR (30:2 edo eskuak soilik) 100 eta 120 bpm-tan eta aplikatu AED berehala"]
BreathCheck -->|"Bai (normal arnasa hartzen du)"| TraumaCare["Immobilize spine if fallen, cool burns with cool running water for 20 min, transport to ER"]
Physics and pathophysiology of electrical trauma¶
When an electrical circuit forms across the human body, the severity of cellular and organ destruction is governed by six physical variables summarized by Ohm's Law (\(I = V / R\), where current equals voltage divided by resistance) and Joule's First Law of Heating (\(Q = I^2 \times R \times t\), where thermal heat generated equals the square of the current multiplied by tissue resistance and contact duration):
- Amperage (Current intensity in milliamperes, mA): Amperage is the primary physiological killer, determined by the driving voltage divided by skin and internal tissue resistance.
- Tentsioa (potentzial elektrikoa voltetan, V): klinikoki banatuta: tentsio baxua (1.000 voltiotik beherakoa, esaterako, 120 V-ko Ipar Amerikako sarea, 230 V-ko Europako/Erresuma Batua/Australiako sare elektrikoa eta 400 V-ko kable komertzial trifasikoa) eta tentsio altua (1.000 voltiotik gorako banaketa-linea gisa). 4.160 V eta 34.500 V bitartekoak eta 115.000 V eta 765.000 V bitarteko transmisio-dorreak).
- Resistance (Impedance in ohms, \(\Omega\)): Dry, calloused human palms offer high resistance (up to 40,000 to 100,000 ohms), which limits current flow. However, wet skin, sweaty skin, immersed skin in a bathtub, or broken skin drops epidermal resistance down to 500 to 1,000 ohms. At 1,000 ohms of wet skin resistance, touching a standard 120-volt or 230-volt bathroom appliance delivers 120 to 230 milliamperes directly into the bloodstream, which is more than enough to trigger instant cardiac arrest.
- Type of current: Alternating Current (AC) versus Direct Current (DC).
- Anatomical pathway (Transthoracic vs vertical): Current travels along the path of least electrical resistance (blood vessels, nerves, and muscles) from the entrance contact point to the ground exit point:
- Hand-to-hand (horizontal transthoracic pathway): Current enters one hand, crosses directly through the mediastinum and heart, and exits the opposite hand. This pathway carries the highest mortality rate (~60 percent in high-voltage contacts) due to direct myocardial fibrillation.
- Hand-to-foot (vertical pathway): Current travels from the upper extremity through the thorax, abdominal organs, and leg to the floor.
- Foot-to-foot (stride or step potential pathway): Current enters one foot, crosses the pelvis, and exits the other foot.
- Duration of contact (\(t\)): The longer the body stays connected to the wire, the more thermal heat accumulates inside deep tissues and the skin breaks down, dropping resistance further and accelerating current inflow.
Physiological effects of 50/60 Hz AC current by milliamperes¶
| Current Intensity (mA, 1-second contact) | Physiological Effect on the Human Body | Clinical Outcome |
|---|---|---|
| 1 to 3 mA | Threshold of sensory perception | Mild tingling sensation at the fingertips; no tissue damage |
| 5 to 10 mA | Painful sensory shock | Sharp pain; normal adult can still voluntarily release their grip ("let-go" current) |
| 10 to 20 mA | The "Let-Go" Threshold (Flexor Tetany) | Involuntary tetanic contraction of forearm flexor muscles locks the hand tightly around the wire; victim cannot let go |
| 20 to 50 mA | Thoracic and Diaphragmatic Tetany | Continuous paralysis of the diaphragm and intercostal breathing muscles; causes respiratory arrest and asphyxiation if contact continues |
| 50 to 100 mA | Ventricular Fibrillation (V-Fib) Threshold | Electrical current strikes during the vulnerable cardiac T-wave repolarization window, throwing the heart into chaotic fibrillation |
| 1,000 to 4,000 mA (1 to 4 Amps) | Sustained Myocardial Contraction (Asystole) and Deep Thermal Burns | Complete clamping standstill of the heart muscle combined with massive deep internal tissue cooking |
Alternating Current (AC) versus Direct Current (DC)¶
| Clinical and Physical Feature | Alternating Current (AC: 50 Hz / 60 Hz) | Direct Current (DC) |
|---|---|---|
| Common Real-World Sources | Household wall outlets (120 V / 230 V), kitchen appliances, power tools, commercial HVAC, overhead utility lines | Automotive and EV battery packs (12 V to 800 V), solar photovoltaic arrays, electrified subway third rails, arc welders, lightning |
| Skeletal Muscle Response | Continuous tetanic spasm ("No-Let-Go" phenomenon): Because current reverses direction 50 to 60 times per second, forearm flexor muscles contract continuously, clamping the victim's fist onto the live wire | Single violent ballistic contraction: Produces a single massive muscle spasm that frequently throws the victim several meters backward away from the power source |
| Primary Cardiac Arrhythmia | Ventricular Fibrillation (V-Fib): 3 to 5 times more dangerous than DC at low voltages because the 50/60 Hz cycle repeatedly crosses the vulnerable cardiac repolarization phase | Ventricular Asystole (Cardiac Standstill): High-voltage DC depolarizes the entire myocardium at once, stopping the heartbeat completely |
| Associated Trauma Profile | Prolonged contact time leading to deep internal thermal necrosis, respiratory asphyxiation, and local full-thickness entrance/exit burns | Shorter contact time, but high rates of blunt orthopedic trauma (skull fractures, cervical spine fractures, ruptured spleen, long-bone fractures) from being thrown or falling off ladders |
Safe rescue protocols: breaking electrical contact¶
Danger
Inoiz ez hurbildu eroritako aireko linea elektriko batetik, azpiestazioko transformadore batetik, tren-errail elektrifikatutik edo 1.000 voltiotik gorako tentsio handiko industria-iturritik, eta inoiz ez saiatu goi-tentsioko kable bat mugitzen zurezko erratza, zuhaitz adar edo plastikozko tresna batekin. Tentsio handiko elektrizitateak airea ionizatzen du espazio irekian zehar salto egiteko (arkua) eta zuzenean zure gorputzera zuraren edo plastikoaren gainazaleko hezetasunetik igarotzen da.
1. Behe-tentsioko etxeko eta laneko erreskatea (1.000 Volt azpitik)¶
Norbait 120 voltio edo 230 voltioko etxetresna elektriko batek, luzapen-kableak, erreminta elektrikoek edo akatsen etengailu batek kolpeak jasotzen dituenean:
- Ez ezazu energia iturrian lehenik (beti metodo seguruena):
- Exekutatu etxeko banaketa elektrikoaren panelera (fusible-kutxa edo etengailu-kutxa) eta irauli Etengailu Nagusia Itzali posiziora, edo irauli adar etengailu espezifikoa.
- In the United Kingdom, Europe, and Australia, wall sockets feature an individual rocker switch; if the wall socket is dry and you can reach it without touching the victim or appliance, flip the socket switch off with a dry non-conductive object and pull the plug.
- If the victim is holding an appliance in a wet area (bathroom floor, flooded basement, swimming pool deck, or wet lawn), never step onto the wet floor or touch the appliance cord. Shut off power exclusively at the main house breaker panel while standing on dry flooring.
- Nola bereizi biktima bat etengailua ailegatu ezin denean:
- Ezin bazara etengailura iritsi segundotan eta biktima barruko zoru lehor batean espasmo tetanikoan blokeatuta badago, lur eta biktima isolatu behar duzu:
- A urratsa (isolatu oinak): Zutitu material lodi, guztiz lehor eta ez eroale baten gainean, esate baterako, gomazko ate-zerbitzu baten gainean, gomazko zoladun bota lehorren pare bat, egurrezko ebakitzeko taula lehor batean edo liburu lehor edo tolestutako eskuoihal lehor pila lodi batean.
- Step B (Select a dry non-conductive tool): Grab a long object made of pure insulator material: a dry wooden broom handle, a dry wooden chair, a solid plastic or PVC pipe, a fiberglass tool handle, or a dry rolled-up cotton blanket or dry nylon rope looped around the victim's dry limb or clothing.
- Step C (Verify zero metal or moisture): Ensure the broom handle does not have a metal hanging cap, wet paint, or moisture on it, and never grab the victim's bare skin or damp, sweaty clothing.
- Step D (Break contact in one decisive stroke): Use the wooden pole to shove the victim's hand off the wire, or knock the appliance cord away from the victim, in a single firm push so they do not fall back onto the live conductor.
2. High-voltage emergencies, downed power lines, and step potential¶
When an overhead utility line (carrying 4,000 to 35,000+ volts) snaps during a storm or car crash and falls onto the ground, roadway, fence, or tree, two invisible physical hazards immediately form around the contact point: electrical arcing and ground step potential (voltage gradient).
Understanding step potential and touch potential¶
When a live high-voltage cable rests on the earth, it does not always trip the utility substation breaker, especially if the soil, dry asphalt, or tree branch offers moderate impedance. Instead, thousands of volts of electricity pour continuously into the ground and spread outward in concentric circular rings of decreasing voltage, exactly like ripples spreading outward when a rock is dropped into a pond:
-Directly touching the wire on the ground, the soil may be at 15,000 volts. - At 2 meters (6.5 feet) away, the soil may be at 10,000 volts. - At 4 meters (13 feet) away, the soil may be at 6,000 volts. - At 10 meters (33 feet) away, the soil drops toward 0 volts.
If a rescuer runs or walks with a normal 0.8-meter (2.5-foot) stride into this concentric zone, their front foot plants on the 8,000-volt ring while their back foot rests on the 10,000-volt ring. That 2,000-volt difference between their two feet (step potential) instantly chooses the low-resistance human body over the high-resistance dirt: current shoots up one leg, through the pelvic organs and heart, and down the other leg, causing immediate tetanic collapse onto the ground, where the horizontal body now spans an even wider voltage gap (bridge potential), proving rapidly fatal.
Similarly, touch potential occurs when a person stands on the ground and touches a metal chain-link fence, metal guardrail, or vehicle body that is touching a downed power line hundreds of meters down the street.
How to escape a downed power line zone (Shuffle or Bunny-Hop)¶
If you suddenly realize you are standing within 10 to 20 meters (33 to 65 feet) of a downed power line, or if you feel a tingling sensation in your legs and feet:
- Freeze your stride immediately: Do not take another walking step, and never run.
- Use the Two-Foot Shuffle method:
- Press your ankles and the inner edges of both shoes tightly together so your feet touch side-by-side.
- Slowly shuffle backward or away from the downed wire by sliding one foot forward only a few centimeters along the ground so the heel of your leading foot never passes the toes of your trailing foot, keeping both soles in continuous contact with the same voltage ring.
- Or use the Two-Foot Bunny-Hop method:
- Press your knees, ankles, and feet tightly together, cross your arms firmly against your chest so you do not lose balance and touch the ground with your hands, and hop away with both feet leaving and landing on the ground at the exact same instant.
- Never hop on one foot (if you fall over, your outstretched body will span multiple voltage rings).
- Continue shuffling or hopping until you are at least 10 meters (33 feet) away on dry ground, or 20 meters (65 feet) away if the pavement or grass is wet.
3. Trapped inside a vehicle touching a downed power line¶
If a utility pole falls across your car or truck:
- Ibilgailuaren barruan egon: Kotxea sutan ez dagoen bitartean, leku seguruena kabina barruan lasai esertzea da. Autoaren metalezko karrozeriak Faraday kaiola gisa jokatzen du, gomazko pneumatikoek isolamendu partziala eskaintzen duten bitartean, elektrizitatea kanpoko azalaren inguruan bideratzen. Ez ukitu metalezko ateen markoak, leihoen biraderak edo irratia, eta deitu 911, 112 edo 999 zenbakira zure telefono mugikorrean. Ohartarazi ingurukoei ozen pitzatutako leiho batetik gutxienez 15 metro (50 oin) atzera egon daitezen.
- Larrialdi-jauzi eta nahasketa ebakuazioa (ibilgailuak su hartzen badu BAKARRIK):
- If smoke or flames break out in the engine bay or cabin, you must exit without ever touching the metal car and the ground at the same time (which would turn your body into a direct ground bridge):
- Open the car door wide, being careful not to touch the exterior painted metal panel.
- Stand up on the interior floorboard or plastic door sill, cross your arms tightly over your chest, and tuck your chin.
- Jump clear of the vehicle so that both feet leave the car before either foot touches the ground, and land with both feet pressed tightly together.
- Do not stumble backward and touch the car with your hand. Immediately shuffle or bunny-hop with both feet together for at least 15 meters (50 feet) before walking normally.
Step-by-step medical first aid once the victim is clear¶
Once the power is off or the victim has been safely separated from the conductor, electrical trauma requires a structured C-A-B-C-D-E trauma resuscitation approach because electrical shock simultaneously causes cardiac arrest, central respiratory paralysis, spinal fractures, and thermal burns.
Step 1: Assess responsiveness, breathing, and start CPR / AED¶
- Tap the victim's shoulders and shout to check responsiveness while scanning the chest for normal breathing for no more than 10 seconds.
- Why prolonged CPR is essential in electric shock and lightning:
- Unlike elderly victims of coronary artery blockages, victims of electric shock or lightning are often young with healthy hearts whose cardiac conduction system was momentarily scrambled into ventricular fibrillation (from AC) or asystole (from DC/lightning), or whose brainstem respiratory center was stunned into prolonged apnea (respiratory arrest).
- If an electrical victim's heart keeps beating (or restarts quickly) but their brainstem breathing center remains stunned, they will die of secondary hypoxic cardiac arrest within minutes unless someone gives them rescue breaths and chest compressions.
- Reverse triage in multi-casualty lightning or high-voltage strikes: Normally, in mass-casualty disasters, rescuers treat breathing victims first and pass over apneic/pulseless victims. In lightning or electrical strikes, the rule is reversed ("Resuscitate the dead"): victims who are groaning and moving have a beating heart and will likely survive, whereas the motionless, blue victim on the ground is in reversible ventricular fibrillation or brainstem respiratory arrest and can be saved with immediate CPR and AED defibrillation.
- Deliver high-quality CPR (30 compressions to 2 rescue breaths):
- Push hard and fast in the center of the chest at 100 to 120 compressions per minute to a depth of 5 to 6 centimeters (2.0 to 2.4 inches) in adults.
- Because respiratory paralysis is a hallmark of thoracic tetany and brainstem stunning, include 2 rescue breaths after every 30 compressions if you are able, using a jaw-thrust maneuver if a fall or spinal injury is suspected.
- Attach an Automated External Defibrillator (AED) as soon as it arrives. Ensure the victim's chest is wiped dry of water or sweat, and place the pads at least 2.5 centimeters (1 inch) away from any scorched entrance burn if possible so skin char does not impede shock delivery.
Step 2: Immobilize the cervical spine and check for blunt trauma¶
Never roll or yank an electrical shock victim upright without considering their spine:
- High-voltage shocks and DC jolts cause violent, simultaneous contraction of the powerful paraspinal muscles, which can cause compression fractures of the thoracic and lumbar vertebrae or posterior shoulder dislocations even if the victim never fell.
- Furthermore, electricians, roofers, and homeowners frequently suffer electric shocks while standing on ladders, scaffolding, or utility poles.
- Keep the victim lying flat on their back, manually stabilize their head and neck in a neutral inline position with both hands if they fell or were thrown, and check for life-threatening arterial odoljarioa. If the victim is unconscious, breathing normally, and starts vomiting, log-roll their entire body onto their side as a single rigid unit while keeping the head, neck, and torso aligned.
Step 3: Treat electrical entrance, exit, and arc burns¶
Electrical burns come in three distinct forms: true contact burns (entrance and exit wounds where current entered the skin and exited to ground), arc flash burns (caused by radiant plasma heat up to 19,000 °C / 35,000 °F when high voltage arcs across the air without entering the body), and secondary thermal flame burns (when sparks ignite the victim's shirt or trousers).
- Search for both the entrance AND exit wounds: Whenever you find a charred, depressed, leathery, or pale bullseye burn on a victim's hand or fingers, always check the soles of their feet, toes, opposite hand, thighs, and scalp for the corresponding exit wound, which frequently looks exploded outward.
- Cool external burns with cool running water for 20 minutes: Once the victim is completely clear of all electrical sources and breathing stably, flush thermal and contact burns gently with cool running tap water (around 15 °C / 59 °F) for 20 minutes. Do not delay CPR to cool burns, and stop cooling if the patient begins shivering (hypothermia).
- Remove constricting jewelry and watches immediately: Deep electrical current causes massive, rapid fluid swelling (edema) along the entire arm or leg within minutes. Slide off all rings, bracelets, watches, and tight boots immediately before the swelling traps them and cuts off blood flow.
- Never apply ice, butter, ointments, or tight circumferential wraps: Cover the cooled entrance and exit wounds loosely with sterile non-adherent gauze or a clean sheet of household plastic cling film laid lengthways over the limb (never wrapped tightly around the limb like a tourniquet).
Step 4: Treat for hypovolemic shock¶
Deep internal electrical burns pull massive volumes of plasma fluid out of the bloodstream into damaged muscle compartments, triggering rapid hypovolemic shock:
- Keep the conscious, breathing patient lying flat and cover them with a light blanket to conserve core body heat.
- Do not give the victim anything to eat or drink (no water, coffee, or pain pills), because patients with moderate-to-severe electrical injuries often require emergency general anesthesia in the operating room for surgical burn debridement or fasciotomy within hours of arrival.
The "iceberg effect": why every electrical shock requires hospital evaluation¶
The single greatest medical danger after surviving the initial shock is the iceberg effect: visible surface skin burns represent less than 5 to 10 percent of the total tissue destruction hiding inside the body.
THE ELECTRICAL INJURY "ICEBERG EFFECT"
[ Tiny Pinpoint Skin Entrance Burn ] <-- Visible Surface (5%)
============================================ Skin Line
/ \
/ 1. Bone heats to extreme temps \
/ 2. Deep periosteal muscle cooks \ <-- Hidden Internal
/ 3. Swelling inside rigid fascia \ Destruction (95%)
/ causes Compartment Syndrome \
/ 4. Dead muscle releases Myoglobin \
/ causing Acute Kidney Failure \
+--------------------------------------------------+
1. Deep muscle necrosis along bone ("Inside-Out Cooking")¶
Why can an electrician have only a 5-millimeter (0.2-inch) blister on their palm and yet lose their entire forearm 48 hours later?
- Inside an arm or leg, compact bone has the highest electrical resistance of any human tissue (roughly 900 ohms-cm, compared to 70 ohms-cm for blood and nerves and 150 ohms-cm for muscle).
- By Joule's Law (\(Q = I^2 R t\)), as electrical current travels up the arm, the central bone acts like the heating element inside a toaster, heating to extreme temperatures and cooking the deep skeletal muscles attached directly to the bone from the inside out.
- The overlying skin, cooled by room air, may look completely pink and unharmed while the deep flexor compartment beneath it is coagulated and necrotic.
2. Acute compartment syndrome (Surgical emergency)¶
Skeletal muscles in the forearms and lower legs are encased inside tough, unyielding fibrous sleeves called fascia.
- As deep electrically burned muscle swells with edema fluid, the pressure inside that closed fascial sleeve skyrockets past 30 mmHg, crushing the arteries and nerves running through the limb (acute compartment syndrome).
- Warning signs (The 6 Ps): Excruciating deep Pain out of proportion to the tiny skin burn (especially dramatic pain when the fingers or toes are passively stretched), Paresthesia (pins-and-needles numbness in the fingers/toes), Pallor (pale or mottled digits), Paralysis (weakness moving the hand/foot), Poikilothermia (limb feels cold), and Pulselessness (a late sign).
- If the patient is not at a hospital where trauma surgeons can perform an immediate decompressive fasciotomy (making long surgical incisions to release the pressure), the entire hand, arm, or leg can die within 4 to 6 hours.
3. Rhabdomyolysis (Myoglobinuria) and acute kidney failure¶
When electrical current bursts millions of skeletal muscle cells, two toxic intracellular substances flood into the bloodstream:
- Potassium (Hyperkalemia): Massive release of potassium from dead muscle cells spikes blood potassium levels, which can trigger lethal secondary cardiac arrest hours after the initial shock.
- Myoglobin (Rhabdomyolysis): Myoglobin is a heavy iron-containing oxygen-binding protein inside muscle fibers. When dumped into the bloodstream, myoglobin filters into the kidneys and precipitates as thick, dark sludgy casts that clog the microscopic renal tubules, causing acute kidney failure (acute tubular necrosis).
- The tea-colored or cola-colored urine warning sign: If anyone who suffered an electric shock passes urine that looks pink, red, reddish-brown, dark tea-colored, or dark cola-colored, they have severe rhabdomyolysis and require immediate emergency intravenous fluid resuscitation in a hospital burn/trauma unit.
4. Pediatric oral commissure (Electrical cord bite) burns¶
Toddlers occasionally chew on live extension cords or charger plugs, creating an electrical arc at the corner of the mouth. Every child with an oral electrical burn must be evaluated at a hospital. Roughly 5 to 14 days after the injury, the dead gray scab sloughs off and can erode into the labial artery, causing sudden arterial lip bleeding. If bleeding starts days later, pinch the lip firmly between your thumb (inside the mouth) and index finger (outside the lip) using clean gauze and go straight to the emergency room.
Mandatory criteria for emergency department evaluation and ECG monitoring¶
Every person who experiences a true electrical shock from mains wiring, tools, or lightning should be evaluated by a physician. Immediate Emergency Department transport and 12-lead electrocardiogram (ECG) monitoring are mandatory if any of the following are present:
- Contact with high voltage (>1,000 V) or lightning, or any loss of consciousness, confusion, or amnesia.
- Any transthoracic pathway (hand-to-hand or hand-to-foot) or prolonged "no-let-go" tetanic lock on a household wire.
- Chest pain, heart palpitations, shortness of breath, visible entrance or exit burns, deep muscle pain, or dark tea-colored urine.
- Pregnancy at any stage (requires immediate fetal monitoring) or pre-existing heart conditions.
Tip
Consider taking a hands-on CPR, AED, and first aid certification course from the Red Cross, St John Ambulance, or the American Heart Association. Knowing how to perform chest compressions and operate an AED immediately after breaking electrical contact doubles to triples a victim's chance of survival.
Maiz egiten diren galderak¶
Can an electric shock cause a heart attack or delayed cardiac arrest hours later if I feel completely fine right now?
If you experienced a high-voltage shock (over 1,000 volts), lost consciousness even briefly, have deep muscle pain or burns, or feel any chest pain or fluttering palpitations, delayed cardiac arrhythmias can occur hours later due to myocardial bruising or potassium leaking from damaged muscle cells, requiring 24-hour hospital ECG monitoring. For a brief low-voltage household shock (120 V to 240 V) where you never lost consciousness and feel well, a quick medical check with a normal 12-lead electrocardiogram (ECG) rules out delayed heart rhythm danger.
Why is household Alternating Current (AC) more dangerous than Direct Current (DC) at the same voltage?
Household alternating current oscillates back and forth at 50 or 60 cycles per second (50/60 Hz), which stimulates human skeletal muscle fibers into a continuous, locked tetanic spasm ("no-let-go" phenomenon). Because the forearm flexor muscles are stronger than the extensor muscles, the victim's hand clamps tightly around the live wire, vastly increasing the duration of current flow and internal tissue cooking. In addition, 50/60 Hz AC repeatedly strikes the heart's vulnerable repolarization window, triggering ventricular fibrillation at three to five times lower current than DC.
Is it safe to use a wooden broomstick or dry tree branch to push a downed overhead power line off someone?
No, never attempt to use a wooden broomstick, tree branch, plastic pipe, or rubber gloves to move an overhead power line or any high-voltage wire (>1,000 volts). Household non-conductive tools only insulate against low-voltage household current (110 V to 240 V). At distribution voltages of 4,000 to 35,000 volts, electricity arcs effortlessly through the air and travels down microscopic moisture and resin pathways in wood or plastic directly into the rescuer, killing both people. Always stay 10 to 20 meters (33 to 65 feet) away and wait for the electric utility company to de-energize the line.
Why do I have to shuffle or hop with both feet together near a downed power line even if I am not touching the wire?
When a live high-voltage wire touches the earth, electricity radiates outward through the soil in concentric rings of decreasing voltage, like ripples in a pond. If you walk normally, your front foot lands on a ring of one voltage while your back foot touches a ring of a different voltage. That voltage difference between your feet (step potential) forces high-amperage current to shoot up one leg, through your pelvis and heart, and down the other leg. Keeping both feet pressed tightly together and shuffling or hopping ensures both feet stay at the exact same electrical potential so no circuit forms through your body.
Why does an electrical shock victim need to go to the emergency room if their skin only has a tiny pinpoint burn?
Electrical injuries follow the "iceberg effect," where 95 percent of the damage occurs out of sight deep inside the body. Because bone has the highest electrical resistance of any tissue, current traveling through an arm or leg heats the bone to extreme temperatures, cooking the deep muscle layers wrapped around the bone while leaving the outer skin looking nearly normal. This deep muscle destruction can rapidly cause limb-threatening compartment syndrome and release muscle proteins (myoglobin) that cause acute kidney failure within hours.
What should a pregnant woman do if she receives a minor household electric shock?
Any pregnant person who receives an electric shock from a household outlet, appliance, or faulty cord, especially if the current entered the hand and grounded through the feet, should go to the emergency department or obstetrical triage unit immediately, even if she feels completely unharmed and has no skin burns. Amniotic fluid and the fetal circulation offer very low electrical resistance, meaning a small current that barely tingles the mother's hand can pass directly through the uterus and affect the baby's heart rate or placenta.
Erlazionatutako gidak¶
- Cardiopulmonary resuscitation (CPR) and AED
- Burns: classification and first aid
- Sua elektrikoa eta txinpartak
- Thunderstorms and lightning safety
- Odol-kontrol larria
- Larrialdietarako telefono zenbakiak herrialdearen arabera
Iturriak egiaztatu¶
- American Heart Association (AHA, United States) and International Liaison Committee on Resuscitation (ILCOR): Guidelines for Cardiopulmonary Resuscitation and Emergency Cardiovascular Care (Special Circumstances of Resuscitation: Electrical Injury and Lightning)
- European Resuscitation Council (ERC): Guidelines on Cardiac Arrest in Special Circumstances , Electrocution and Lightning Strike
- Occupational Safety and Health Administration (OSHA, United States) and National Institute for Occupational Safety and Health (NIOSH / CDC, United States): Electrical Safety, Step Potential, and Arc Flash Trauma Directives
- American Burn Association (ABA, Estatu Batuak): Advanced Burn Life Support (ABLS) Elektriko eta Tximistaren Lesioetarako Praktika Klinikorako Gidalerroak
- Osasun Zerbitzu Nazionala (NHS, Erresuma Batua) eta St John Anbulantzia (Erresuma Batua): Goi-tentsioko eta behe-tentsioko deskarga elektrikoetarako lehen laguntza-protokoloak