Secosse première à choc électrique: li nga wara def ak li ngay moytu¶
Emergency numbers differ by country. This page uses 911, the number for the United States and Canada. Many other countries use 112, 999, or another number. Find the number for your country.
Gaañ-gaañu yi bawoo ci kuuraŋ bokk nañu ci jafe-jafe yi gëna njuuj njaaj ak jafe-jafe ci medsin trauma. Doonte barab yi der bi di daje ak ñoom mën nañu melni lu tuuti, lakk bu fës ci kaw suuf si, courant électrik biy jaar ci yaram wi dafay soppi nekk energie thermique bu am doole ci biir yaram wi ci yooni anatomie yu xóot yi. Ci ay milisegond, courant kër wala usine mën na indi paralyse musculaire budul bëgg-bëgg buy tëj victime bi ci conducteur biy dundu, génne fibrillation ventriculaire buy ray nit wala arrêt respiratoire, coaguler reso vasculaire yu xóot, togg sidit skeletal periosteal ci yax bu tàng, ak fracture contraction yu am doole ci collu bi.
Regle bi njëkk ci bépp jafe-jafe kuuraŋ mooy kaaraange kiy mucc: soo laalee nit ku wéy di laal kuuraŋ bu am kuuraŋ, dangay nekk ñaareelu gaañ-gaañu ci saasi. Xam ni ñuy xàjjale dooley kër ak njaay, tàqale ab victime bu am voltage bu woyof jëfandikoo ay isolant yu waw yu amul yoonale, rëcci ci bague composé yu am voltage ci suuf (potentiel de jéego) ci ligne utile bu am voltage bu kawe bu wàcci), tàmbali resuscitation cardioPRolnaire ci saasi ak resuscitation (C rabdomyolyse ak feebaru compartiment dañuy muccal nit.
Defal lii leegi¶
- Bul laal kiñ laal ak sa loxo, yéere, wala lenn luy weñ wala lenn lu tooy fekk mu ngi laal fi kuuraŋ bi di joge. Yaramu nit dafay yóbbu kuuraŋ; jàpp nit ku am kuuraŋ dafay jaar ci sa xol ak sa sistem nerf.
- Woowal ci saasi serwiisu paj mu jamp te nga wax ni amna gaañ-gaañu kuuraŋ. Woowal sa nimero paj mu jamp (911 ci Etats Unis ak Canada, 112 ci Mbootaayu Ëroop yépp, 999 ci Royaume-Uni) wala nga xool nimero paj mu jamp, nga laaj fajkat yi ak liggéeyukaay yiy joxe kuuraŋ sudee amna ligne yu am voltage bu kawe.
- Fësal kuuraŋ bi ci saasi sudee kuuraŋ bi am voltage bu woyof la ci kër gi wala ci liggéeyukaay yi (ci suufu 1,000 volt). Bësal interruptëru diisaayu sircuit bi ci paanelu serwiis kuuraŋ bi, dindi fuse bi, fay interruptëru prise bi ci kuuraŋ bi (fu fiil bi nekk ci fiil bi), wala dindi fiil bi ci kuuraŋ bi). bu yàquwul te sori ci ndox mi.
- Dellu ginaaw lu mu néew 10 ba 20 meetar (33 ba 65 pied) sudee source bi am voltage bu yéeg (lu ëpp 1,000 volt), ligne kuuraŋ bu wàcci, wala bëréet. Bul musa jéema dindi fiil bu am voltage bu rëy ci nit ku yor broomstick wala bànxaas bu am voltage bu yéeg, pole yu amul conducteur; Xaaral ba teknisien yi firndeel ni reso bi daa dindi kuuraŋ ba noppi def ko ci suuf.
- Sudee kuuraŋ bi am voltage bu woyof mënu ñu ko fay ci saasi, dangay puus kiñ laal wala fiil bi nga jëfandikoo lu waw, lu dul yóbbu kuuraŋ. Taxaw ci kaw surface bu waw buy isoler (lu melni tapis de caoutchouc, tablo dénk bu wow, wala paccu surnaal bu dëll, fibre de bois) tuyo PVC bu waw, wala buum wëtteen bu waw buñ defaree boucle ngir dagg contact bi.
- Saytu ni nit ki bindoo ak ni muy noyyee ci saa si kuuraŋ bi génne ko, nga tàmbali CPR ci saasi su ko jaree. Sudee nit ki tontuwul te noyyiwul nimu waree (wala muy noyyi bu baax), tàmbalil dundal xol ak pomp (CPR) ci 100 ba 120 yoon ci simili bu nekk, nga takk benn defibrillateur externe automatisé (DEA) bi benn yegsee; sudee dañuy noyyi, seddal lépp luñuy gis lakk ak ndox mu sedd muy wal 20 simili, nga bàyyi seen baat ak seen yaxu ndigg ñu taxaw.
flowchart TD
Start["Nit kuy jokkoo ak kuuraŋ"] --> HVCheck{"Ndax voltage bu kawe la (>1,000 V), liiñ bu wacc, wala environmaa bu tooy?"}
HVCheck -->|"Waaw: Voltage bu kawe wala liiñ bu wàcci"| HVProtocol["Deel nekk ci diggante 10 ba 20 meetar (33 ba 65 pied); BULEEN MUSAA jege wala jëfandikoo poto"]
HVProtocol --> CallUtil["Woowal 911 / 112 / 999 ak serwiis kuuraŋ; shuffle ak tànk yi boole sudee ci biir zone"]
HVCheck -->|"No: kër gu am tension bu woyof (110 V ba 240 V)"| CutPower{"Ndax mën nga tëj diisaalekat bi wala dindi fiil bi?"}
CutPower -->|"Waaw"| PowerOff["Dellu ci disjoncteur bi ci Off wala nga dindi fiil bi isolé"]
CutPower -->|"Déedet"| Insulate["Taxaw ci kaw kawsu wala bant bu waw; puus cable bi wala victime bi ak bois bu waw wala jumtukaayu plastik"]
PowerOff --> Assess["Victim amul courant: Xool tontu ak noyyig 10 seconde"]
Insulate --> Assess
Assess --> BreathCheck{"Ndax kiñ ci lor dafay tontu ak noyyi bu baax?"}
BreathCheck -->|"Dédeet (Tontuwul / Agonal gasps)"| StartCPR["Tambalil CPR (30:2 wala loxo kese) ci 100 ba 120 bpm nga def AED ci saasi"]
BreathCheck -->|"Waaw (Noyyi bu baax)"| TraumaCare["Immobiliser yaxu ndigg sudee daanu, sedd lakk ak ndox mu sedd muy daw 20 simili, yóbbu ko ER"]
Fisik ak patofisioloji trauma kuuraŋ¶
Su amee sircuit kuuraŋ ci yaram wi, diisaayu yàqu-yàqu selul yi ak cër yi a ngi aju ci 6 variable physique yuñ tënk ci Yoon Ohm (\(I = V / R\), fu courant bi tollu ci voltage xaaj ak resistance) ak **Yoon bu njëkk bu Joule ci Tàngoor, R$2time, R$2 tàngoor wiñ defar mingi tollu ci kaare courant bi ñu yokk ko ci mbañeelu tisu bi ak diiru jokkoo bi):
- Ampère (Doole courant bi ci milliampère, mA): Ampée mooy killer physiologique bi njëkk, ñu koy xam ci voltage biy dawal xaaj ko ak mbañeelu der bi ak tisu bi ci biir.
- ** Voltage (Potentiel électrique ci volt, V):** Xaajale ko ci voltage bu woyof (ci suufu 1,000 volt, lu melni 120 V réseau Amerique du Nord, 230 V réseau Europe/UK/Australie, ak su 400 V voltage bu ëpp ñatti fase, ligne yiy séddale 4.160 V ba 34.500 V ak tour yiy joxe 115.000 V ba 765.000 V).
- Bañ (Impedans ci ohms, \(\Omega\)): Palm yu nit yu waw, yu amul yaram dañuy joxe bañ bu rëy (ba 40,000 ba 100,000 ohm), te loolu dafay tere courant bi dem. Waaye, der bu tooy, der bu ñaq, der bu suul ci biir ban, wala der bu yàqu dafay wàññi resistance epiderme bi ba 500 ba 1,000 ohms. Ci 1,000 ohms yu der bu tooy mëna xeex, laal benn aparey bu 120 wala 230 volt ci saal bi dafay joxe 120 ba 230 milliampère ci deret ji, lu ëpp lu doy ngir xol bi dakkal ci saasi.
- Xeetu courant bi: Courant alternatif (CA) ak courant direct (DC).
- Yoon anatomique (Transthoracic vs vertical): Courant dafay jaar ci yoonu resistance électrique bi gëna néew (vesoo deret yi, neer yi, ak sidit yi) daale ko ci point bi ñuy duggee dem ba ci point bi ñuy génnee ci suuf:
- Loxo-ci-loxo (yoon transtorasik bu tëdd): Courant bi dafay dugg ci benn loxo bi, jaar ci mediastinum bi ak xol bi, ba noppi génn ci beneen loxo bi. Yoon woowu mooy gëna bari luñuy génn àdduna (~60 pursaa ci kontakt yu am voltage bu kawe) ndax fibrillation myocardial direct.
- Loxo-ba-tànk (yoon wi taxaw): Courant dafay joge ci kaw tànk bi jaar ci thorax bi, cër yi ci biir bi, ak tànk bi dem ba ci suuf.
- Tànk-ci-tànk (yoon wi mëna dem wala jéego): Courant dafay dugg ci benn tànk bi, daal di jàll ci pelvis bi, daal di génn ci beneen tànk bi.
- Duration of contact (\(t\)): Lu yaram wi di gëna yàgg di nekk ci lëkkaloo ak fiil bi, tàngoor wi dafay gëna bari ci biir tisu yu xóot yi, der bi dafay yàqu, di wàññi resistance bi gëna gaaw, ba noppi gaawlu duggu courant bi.
Efe fisiyolojiku courant CA 50/60 Hz ci miliampere¶
| Intensité courant (mA, 1-second contact) | njeextalu physiologique ci yaramu nit | Résultat clinique |
|---|---|---|
| 1 ba 3 mA | Buntu gis-gis bi am ci yëg-yëg | Xam-xam bu woyof ci catu baraam yi; amul benn yàqu-yàqu ci tisu |
| 5 ba 10 mA | Choc sensoriel bu metti | metit wu tar; mag ñi mën nañu ba leegi bàyyi seen loxo ("let-go" courant) |
| 10 ba 20 mA | Bayi-Dem" Buntu (Tetany Flexor) | Contraction tetanic bu sidit flexor yi ci kanam loxo bi dafay tëju loxo bi bu baax ci fiil bi; kiñ ci lor mënul bàyyi |
| 20 ba 50 mA | Tetani torasik ak diafragm | Paralisis bu wéy ci diaphragm bi ak sidit yiy noyyi ci diggante costal yi; dakkal noyyig ak asphyxie sudee laal bi wéy |
| 50 ba 100 mA | **Fibrilaasioŋ ventrikular (V-Fib) ** | Courant électrik dafay dal ci palanteeru repolarisasioŋ onde T bu xol bi, sànni xol bi ci fibrillation bu jaxasoo |
| 1000 ba 4000 mA (1 ba 4 Ampère) | Kontraksioŋ miokardial bu yàgg (Asystole) ak lakk yu xóot | taxawaayu sidit xol bu mat sëkk boole ci toggu tisu bu xóot bi ci biir |
Courant alternatif (CA) ak courant direct (DC)¶
| Màndarga klinik ak yaram | Courant alternatif (CA: 50 Hz / 60 Hz) | Courant direct (DC) |
|---|---|---|
| Sources yu gëna bari ci àdduna | prise mur kër (120 V / 230 V), aparey waañ, jumtukaayi kuuraŋ, HVAC komersiyaal, ligne utilite ci kaw | Pack batëri oto ak EV (12 V ba 800 V), matrix fotowoltaik jant, ñetteelu rail metro kuuraŋ, soudeur arc, bëréet |
| Tontu sidit yax yi | Spasm tetanik bu wéy (fenomen "No-Let-Go"): Ndax courant bi dafay soppi yoon wi 50 ba 60 yoon ci seconde, sidit flexor yi ci loxo bi dañuy wéy di gëna xëcc, di tëye fistu kiñ laal ci fiil biy dundu | Benn contraction ballistic bu am doole: Defar benn spasme musculaire bu mag buy faral di sànni kiñ laal ay meetar ci ginaaw fu sori ci source kuuraŋ bi |
| Aritmi karjaak bu njëkk | Fibrillation ventriculaire (V-Fib): 3 ba 5 yoon la gëna ñaawe DC ci voltage yu woyof ndax cycle 50/60 Hz dafay jàll lu bari yoon ci fase repolarisasioŋ karjaak bu ñakk kaarange | Asystole ventriculaire (xol bu taxaw): DC bu am voltage bu kawe dafay depolarise myocarde bi yépp ci saasi, dakkal beppu xol bi |
| Profil trauma bu ànd ak moom | Diiru jokkoo bu yàgg mën na indi nekrose termik bu xóot ci biir, asphyxie respiratoire, ak lakk bu mat sëkk ci dugg/génn | Jamonoy jokkoo bu gàtt, waaye bariwaayu trauma orthopédique bu dëgër (fractures crâne, fractures cervical, fractures spleen, fractures yax yu gudd) ndax dañu leen sànni wala ñu daanu ci seel yi |
Protokolu xettali bu wóor: dagg jokkolante kuuraŋ¶
Danger
Bul musa jegesi 10 meetar (33 pied) ci liiñ kuuraŋ bu wàcci, transformatëru substation, rail saxaar bu am kuuraŋ, wala bépp balluwaay usine bu am voltage bu ëpp 1,000 volt, te bul musa jéema toxal fiil bu am voltage bu rëy ak balaa dénk, car garab, wala plastik ci toxal. Kuuraŋ bu am voltage bu kawe dafay ionise air bi ngir mu tëb (arc) ci barab bu ubbeeku, daal di wàcci directement ci surface guus gu dénk wala plastik bi dugg ci sa yaram.
1. Wallu kër ak barabu liggéey bu woyof (ci suufu 1,000 Volt)¶
Su amee aparey bu am 120 wala 230 volt, fiil buy yokk, jumtukaayu kuuraŋ, wala interruptër bu defoon njuumte:
- Dagg kuuraŋ bi ci balluwaay bi (mooy anam wi gëna wóor saa yu nekk):
- Daw nga dem ci paanelu séddale kuuraŋ bi ci kër gi (boîte de fuse wala boîte de disjoncteur) nga wëlbati Disjoncteur bu mag bi ci position Off, wala nga wëlbati disjoncteur bi ci branche bi.
- Ci Royaume-Uni, Europe, ak Australie, prise yi dañuy àndaale ak interruptër buy yëngu; Sudee prise bi dafa wow, te mën nga ko yegg te doo laal kiñ laal wala aparey bi, nga jël lu waw ludul yóbbu kuuraŋ, nga dindi fiil bi.
- Sudee kiñ ci lor dafa yor aparey ci barab bu tooy (dëru duus, sous-sol bu fees, pond piscine, wala gazon bu tooy), bul musa yéeg ci dër bu tooy bi wala laal buum aparey bi. Soo taxawee ci dër bu wow, dangay fay kuuraŋ bi ci paanelu interruptër bi ci kër gi.
- Ni ñuy tàqalee victime sudee breaker bi mënul yegg:
- Sudee mënoo yegg ci disjoncteur bi ci diir bu gàtt, te kiñ laal dafa tëju ci spasme tetanic ci kaw dër bu wow ci biir kër gi, danga wara isoler sa bopp ci suuf ak kiñ laal:
- Jéego A (Isoler say tànk): Taxaw ci kaw lu dëll, lu waw lëmm, ludul mëna yóbbu kuuraŋ lu melni tapis bu am kawsu, dàll yu waw yu am sol kawsu, tablo daggukaayu dénk bu waw, wala téere yu waw yu dëll wala sarbet yu waw yuñ plie.
- Jéego B (Tannal jumtukaay bu waw budul yóbbu kuuraŋ): Jëppal lu gudd luñu defaree macceer isolant bu sell: jàppukaayu balaas bu waw, chaise dénk bu waw, tuyo plastik bu dëgër wala PVC, jàppukaayu jumtukaayu fibre de verre, wala mbàjji wëtteen bu waw wala buum nylon bu waw.
- Jéego C (Xam ndax amul benn wen wala guus): Fexeel ba jàppukaayu bale bi amul benn mbaxana buy weer, peinture bu tooy, wala guus, te bul musa jàpp der bu amul dara wala yéere yu xawa tooy ak yu xawa ñaq.
- Jéego D (Dagg jokkool bi ci benn yoon bu am solo): Jëfandikool poto bant bi ngir dindi loxo kiñ laal ci fiil bi, wala nga mbëkk buum aparey bi fu sori ci kiñ laal, ci benn lakk bu dëgër ngir ñu baña daanu ci kaw conducteur biy dundu.
2. Emergence yu am voltage bu kawe, ligne kuuraŋ yu wacc, ak potentiel¶
Su amee liiñ bu am doole ci kaw (bu yor 4,000 ba 35,000 volt) bu dagg ci jamonoy taw wala aksidaa oto ba noppi daanu ci suuf, ci tali, ci ñag, wala ci garab, ñaari loraange yuñudul gis dañuy forme ci saasi ci barab bi ñuy laal: ** arc électrique.
Xam potentiel jéego ak potentiel laal¶
Su fiil bu am voltage bu kawe nekk ci kaw suuf, du saa yu nekk lay dindi interruptëru substation utilite bi, rawatina sudee suuf si, asphalte bu wow bi, wala car garab yi dañu am impedance bu yam. Lu moy loolu, ay junni volt kuuraŋ dañuy wéy di tuuru ci suuf si, di tasaaroo ci biti ci bague circulaire yu am voltage buy wàññeeku, muy nuru ay ripple yuy tasaaroo ci biti suñu sànnee xeer ci benn pond:
-Soo laalee cable bi ci suuf, suuf si mën na nekk ci 15,000 volt. - Soo nekkee ci diggante 2 meetar (6,5 pied), suuf si mën na nekk ci 10,000 volt. - Soo nekkee ci 4 meetar (13 pied), suuf si mën na am 6,000 volt. - Soo yeggee ci 10 meetar (33 pied), suuf si dafay wàcci ba 0 volt.
Sudee ab wallukat dafay daw wala dox ak tànk bu mat 0.8 meetar (2.5 pied) ci zone concentrique bi, seen tànk kanam dafay jëm ci ring bu 8,000 volt bi, seen tànk bi ci ginaaw dafay tëdd ci ring bu 10,000 volt bi. Boobu ** 2,000-volt wuute ci seen ñaari tànk (potentiel jéego) ** ci saasi tànn yaram nit bu néew doole ci kaw tilim bu bari doole: courant dafay yéeg ci benn tànk, jaar ci cër yi ak xol, ak wàcci ci beneen tànk bi, di waral tetanic voltage ci saasi daanu ci kaw suuf, gap (potentiel pont), di gaawa ray nit.
Ci anam wu mel nii, potentiel touch dafay am su nit taxawee ci suuf ba noppi laal benn ñag buñ defaree wen, balustrade buñ defaree wen, wala yaram wu oto bu laal liiñ bu wàcci téemeeri meetar ci mbedd mi.
Ni ñuy rëcci ci zone ligne kuuraŋ bu daanu (Shuffle wala Bunny-Hop)¶
Soo jekki saa rek nga gis ni danga taxaw ci diggante 10 ba 20 meetar (33 ba 65 pied) ci liiñ bu wacc, wala soo yëgee ni say tànk ak say tànk dañuy yëngu:
- Dakkal sa dox ci saasi: Bul dox beneen jéego, te bul musa daw.
- Jëfandikool anam Shuffle ñaari tànk:
- Toggal say tëstën ak catu biir ñaari dàll yi ñu boole bu baax suko defee say tànk ñu laal seen biir.
- Dellu ndànk ci ginaaw wala nga sori ci fiil bi wàcci, nga gliise benn tànk ci kanam ay santimet yu néew ci suuf suko defee taloŋu sa tànk bi jiitu du musa romb baraami sa tànk bi ci ginaaw, nga tëye ñaari tànk yi ci diggante bu wéy ak benn ring voltage.
- Wala nga jëfandikoo anam Bunny-Hop bu am ñaari tànk:
- Toggal say wóom, say tànk, ak say tànk bu baax, nga jàll say loxo ci sa dënn ngir nga baña ñàkk ekilibre, nga laal suuf ak say loxo, nga tëmb dem ak ñaari tànk yi bàyyi ak wàcci ci suuf ci saa si.
- Bul musa tëb ci benn tànk (soo daanu, sa yaram wi tàllal dafay jàll ci bague voltage yu bari).
- Wéyal di yëngal wala di tëb ba nga yegg ci 10 meetar (33 pied) ci suuf su wow, wala 20 meetar (65 pied) sudee trotoire bi wala ñax mi tooy na.
3. Dañu tëju ci biir oto buy laal liiñ bu wacc¶
Sudee poto serwiis publik dafa daanu ci sa oto wala kamioŋ:
- Demal ci biir oto bi: Fa oto bi tàkkul, barab bi gëna wóor mooy nga toog ci biir kabine bi nga ànd ak dal. Yaramam oto bi dafa melni kaaf Faraday ci noonu pënu kawsu yi dañuy isoler wàll wi, di yóbbu kuuraŋ ci der bi ci biti. Bul laal kaadaru buntu weñ yi, vile yu palanteer yi, wala radio, nga woo 911, 112, wala 999 ci sa telefon. Àrtu bu baax ñiy seetaan ci palanteer bu xar, ñu baña dem 15 meetar (50 pied) ci ginaaw.
- Evakuaasioŋ urgent ci tëb-ak-jaxas (sudee oto bi dafa tàkk rek):
- Su amee saxaar wala xal yuy tàkk ci barabu motër bi wala ci kabine bi, danga wara génn te doo laal oto bi ak suuf si benn yoon (loolu dina tax sa yaram nekk pont bu jëm ci suuf):
- Ubbi buntu oto bi bu baax, nga moytu laal pano weñ biñ defaree biti.
- Taxawal ci kaw dër bi ci biir wala ci buntu plastik bi, nga takk say loxo bu baax ci sa dënn bi, nga tëye sa sikkim.
- Tëmb fu sori ci oto bi, sa ñaari tànk yi génn ci oto bi balaa benn ci tànk yi di laal suuf, nga wàcci nga boole sa ñaari tànk yi bu baax.
- Bul mbëggéel ci ginaaw nga laal oto bi ak sa loxo. Ci saasi shuffle wala bunny-hop ak ñaari tànk yi boole lu mu néew 15 meetar (50 pied) balaa ngay dox nimu waree.
Jéego ak jéego ci paj mu njëkk ginaaw bi kiñ laal wéree¶
Su kuuraŋ bi dee wala ñu tàqale kiñ ci lor ci ki koy yóbbaale, trauma electrik dafay laaj C-A-B-C-D-E trauma resuscitation ndax choc electrik dafay indi arrêt cardiaque, paralyse respiratoire centrale, fractures spinale, ak burns thermique.
Jéego 1: Xoolaat tontu, noyyi, ak tàmbali CPR / AED¶
- Bësal mbaggu kiñ laal nga yuuxu ngir xool ndax dafay tontu ci saasi ngay scanner dënn bi ngir xam ndax dafay noyyi bu baax, du ëpp 10 seconde.
- Lu tax CPR bu yàgg lu am solo la ci choc électrique ak bëréet:
- Ñi am choc électrique wala bëréet wuute nañu ak mag ñi am choc électrique wala bëréet, dañuy faral di nekk ndaw yu am xol yu wér, seen sistemu conduction cardiaque dafa mujjee nekk fibrillation ventriculaire (ci AC) ** wala ** asystole (ci DC, respiratoire wala bëréet) apnée bu yàgg (arrêt respiratoire).
- Sudee xol kuuraŋ bi dafa wéy di tëf (wala mu tàmbaliwaat ci saasi) waaye seen center respiratoire bu yuur gi des ci jaxasoo, dina ñu dee ci ñaareelu arrêt cardiaque hypoxic ci diir bu gàtt fileek kenn joxul leen ** noyyig mucc ak compressions ci dënn bi **.
- Triage inverse ci bëréet yu bari yu ñàkk seen bakkan wala dóor yu am voltage bu kawe: Daanaka, ci musiba yu bari, wallukat yi dañuy njëkka faj ñi loru ñuy noyyi ba noppi romb ñi loru ci apnée/pulseless. Ci bëréet wala dóor kuuraŋ, dañuy soppi sàrt bi ("Dekkal ki dee"): ñi ci loru ñuy onku ak di yëngu seen xol dafay tëf te dina ñu mucc, waaye kiy loru te baxa bu nekk ci suuf mingi ci fibrillation ventriculaire buy dellu ginaaw wala tronc yuur gi mën na nekk ci noyyig immediate ak CPR ak defibrilaasioŋ AED.
- Defal CPR bu baax (30 kompresioŋ ngir 2 noyyig xettali):
- Toxal bu baax te gaaw ci diggu dënn bi ci 100 ba 120 kompresioŋ ci simili bi ba ci xóotaayu 5 ba 6 santimet (2.0 ba 2.4 pouce) ci mag ñi.
- Ndax paralysie respiratoire dafay màndargaal tetany thoracique ak tronc cerebral bu yéeme, boole ci 2 noyyig rëcci ginaaw 30 compressions yu nekk soo ko mënee, jëfandikoo manœuvre jaw-thrust sudee dañu jàpp ni daanu wala gaañ-gaañu ci yaxu ndigg li.
- Takkal benn Defibrillateur externe automatique (DEA) bimu yegsee. Fexeel nga fomp dënnu kiñ laal bamu waw ci ndox wala ñaq, nga teg pad yi 2.5 centimètre (1 pouce) fu sori ci bépp lakk bu lakk bu dugg su ko mënee suko defee char der bi baña tere shock bi joxe.
2ème étape: Nga tëye collu cervical bi nga xool ndax amna trauma bu dëgër¶
Bul musa yëngal wala yëngal ku ñàkk kuuraŋ mu jub te doo xool seen yaxu ndigg:
- Choc yu am voltage bu kawe ak yëngu DC dañuy waral sidit paraspinal yu am doole yi di gëna xëcc, te loolu mën na waral ** fractures compression ci vertebre thoracique ak lumbaire ** wala ** dislocations ci mbagg yi ci ginaaw ** doonte kiñ laal musul daanu.
- Rax ci dolli, ñiy liggéey ci kaw kër yi, ñiy liggéey ci kaw kër yi, ak boroom kër yi dañuy faral di am choc kuuraŋ suñu taxawee ci kaw seel yi, scaffold yi wala poto yi.
- Fexeel kiñ laal mu tëdd ci ginaawam, nga dakkal boppam ak baat bi ci position neutre ak ñaari loxo yi sudee daanu wala ñu sànni ko, nga xool ndax arteriel bi mën na ray ko deret. Sudee kiñ ci lor xëm na, noyyi bu baax, ba noppi tàmbali waccu, danga wara laxas yaram wi yépp ci wet gi nekk benn bu dëgër, boole ci tëye bopp bi, baat bi ak yaram wi ñu tolloo.
3ème étape: Faj buntu kuuraŋ, genn, ak lakk arc¶
Lakk kuuraŋ amna ñatti anam yu wuute: lakk dëgg (dugg ak genn gaañ-gaañu fu courant duggee ci der bi ba noppi génn ci suuf), lakk flash arc (li ko waral mooy tàngooru plasma radiant ba 19,000 °C / 35,000 °F), ak coss bu am voltage bu yéeg ci yaram wi arc a xal yu tàng yi dañuy tàkk** (su limyéer yi tàkkee chemise wala patalongi kiñ faat).
- Seetal gaañ-gaañu yi ci dugg ak ci genn: Saa yoo gisee bët bu tàng, bu tass, bu der, wala bullseye bu lewet ci loxo wala baraami kiñ laal, xoolal saa yu nekk sole tànk yi, baraami tànk yi, loxo bi jàkkarloo, pooj yi, ak deru bopp bi xool bu baax
- Cool external burns with cool running water for 20 minutes: Once the victim is completely clear of all electrical sources and breathing stably, flush thermal and contact burns gently with cool running tap water (around 15 °C / 59 °F) for 20 minutes. Do not delay CPR to cool burns, and stop cooling if the patient begins shivering (hypothermia).
- Remove constricting jewelry and watches immediately: Deep electrical current causes massive, rapid fluid swelling (edema) along the entire arm or leg within minutes. Slide off all rings, bracelets, watches, and tight boots immediately before the swelling traps them and cuts off blood flow.
- Never apply ice, butter, ointments, or tight circumferential wraps: Cover the cooled entrance and exit wounds loosely with sterile non-adherent gauze or a clean sheet of household plastic cling film laid lengthways over the limb (never wrapped tightly around the limb like a tourniquet).
Step 4: Treat for hypovolemic shock¶
Deep internal electrical burns pull massive volumes of plasma fluid out of the bloodstream into damaged muscle compartments, triggering rapid hypovolemic shock:
- Keep the conscious, breathing patient lying flat and cover them with a light blanket to conserve core body heat.
- Do not give the victim anything to eat or drink (no water, coffee, or pain pills), because patients with moderate-to-severe electrical injuries often require emergency general anesthesia in the operating room for surgical burn debridement or fasciotomy within hours of arrival.
The "iceberg effect": why every electrical shock requires hospital evaluation¶
The single greatest medical danger after surviving the initial shock is the iceberg effect: visible surface skin burns represent less than 5 to 10 percent of the total tissue destruction hiding inside the body.
THE ELECTRICAL INJURY "ICEBERG EFFECT"
[ Tiny Pinpoint Skin Entrance Burn ] <-- Visible Surface (5%)
============================================ Skin Line
/ \
/ 1. Bone heats to extreme temps \
/ 2. Deep periosteal muscle cooks \ <-- Hidden Internal
/ 3. Swelling inside rigid fascia \ Destruction (95%)
/ causes Compartment Syndrome \
/ 4. Dead muscle releases Myoglobin \
/ causing Acute Kidney Failure \
+--------------------------------------------------+
1. Deep muscle necrosis along bone ("Inside-Out Cooking")¶
Why can an electrician have only a 5-millimeter (0.2-inch) blister on their palm and yet lose their entire forearm 48 hours later?
- Inside an arm or leg, compact bone has the highest electrical resistance of any human tissue (roughly 900 ohms-cm, compared to 70 ohms-cm for blood and nerves and 150 ohms-cm for muscle).
- By Joule's Law (\(Q = I^2 R t\)), as electrical current travels up the arm, the central bone acts like the heating element inside a toaster, heating to extreme temperatures and cooking the deep skeletal muscles attached directly to the bone from the inside out.
- The overlying skin, cooled by room air, may look completely pink and unharmed while the deep flexor compartment beneath it is coagulated and necrotic.
2. Acute compartment syndrome (Surgical emergency)¶
Skeletal muscles in the forearms and lower legs are encased inside tough, unyielding fibrous sleeves called fascia.
- As deep electrically burned muscle swells with edema fluid, the pressure inside that closed fascial sleeve skyrockets past 30 mmHg, crushing the arteries and nerves running through the limb (acute compartment syndrome).
- Warning signs (The 6 Ps): Excruciating deep Pain out of proportion to the tiny skin burn (especially dramatic pain when the fingers or toes are passively stretched), Paresthesia (pins-and-needles numbness in the fingers/toes), Pallor (pale or mottled digits), Paralysis (weakness moving the hand/foot), Poikilothermia (limb feels cold), and Pulselessness (a late sign).
- If the patient is not at a hospital where trauma surgeons can perform an immediate decompressive fasciotomy (making long surgical incisions to release the pressure), the entire hand, arm, or leg can die within 4 to 6 hours.
3. Rhabdomyolysis (Myoglobinuria) and acute kidney failure¶
When electrical current bursts millions of skeletal muscle cells, two toxic intracellular substances flood into the bloodstream:
- Potassium (Hyperkalemia): Massive release of potassium from dead muscle cells spikes blood potassium levels, which can trigger lethal secondary cardiac arrest hours after the initial shock.
- Myoglobin (Rhabdomyolysis): Myoglobin is a heavy iron-containing oxygen-binding protein inside muscle fibers. When dumped into the bloodstream, myoglobin filters into the kidneys and precipitates as thick, dark sludgy casts that clog the microscopic renal tubules, causing acute kidney failure (acute tubular necrosis).
- The tea-colored or cola-colored urine warning sign: If anyone who suffered an electric shock passes urine that looks pink, red, reddish-brown, dark tea-colored, or dark cola-colored, they have severe rhabdomyolysis and require immediate emergency intravenous fluid resuscitation in a hospital burn/trauma unit.
4. Pediatric oral commissure (Electrical cord bite) burns¶
Toddlers occasionally chew on live extension cords or charger plugs, creating an electrical arc at the corner of the mouth. Every child with an oral electrical burn must be evaluated at a hospital. Roughly 5 to 14 days after the injury, the dead gray scab sloughs off and can erode into the labial artery, causing sudden arterial lip bleeding. If bleeding starts days later, pinch the lip firmly between your thumb (inside the mouth) and index finger (outside the lip) using clean gauze and go straight to the emergency room.
Mandatory criteria for emergency department evaluation and ECG monitoring¶
Every person who experiences a true electrical shock from mains wiring, tools, or lightning should be evaluated by a physician. Immediate Emergency Department transport and 12-lead electrocardiogram (ECG) monitoring are mandatory if any of the following are present:
- Contact with high voltage (>1,000 V) or lightning, or any loss of consciousness, confusion, or amnesia.
- Any transthoracic pathway (hand-to-hand or hand-to-foot) or prolonged "no-let-go" tetanic lock on a household wire.
- Chest pain, heart palpitations, shortness of breath, visible entrance or exit burns, deep muscle pain, or dark tea-colored urine.
- Pregnancy at any stage (requires immediate fetal monitoring) or pre-existing heart conditions.
Tip
Consider taking a hands-on CPR, AED, and first aid certification course from the Red Cross, St John Ambulance, or the American Heart Association. Knowing how to perform chest compressions and operate an AED immediately after breaking electrical contact doubles to triples a victim's chance of survival.
Laaj yi ñuy faral di laaj¶
Can an electric shock cause a heart attack or delayed cardiac arrest hours later if I feel completely fine right now?
If you experienced a high-voltage shock (over 1,000 volts), lost consciousness even briefly, have deep muscle pain or burns, or feel any chest pain or fluttering palpitations, delayed cardiac arrhythmias can occur hours later due to myocardial bruising or potassium leaking from damaged muscle cells, requiring 24-hour hospital ECG monitoring. For a brief low-voltage household shock (120 V to 240 V) where you never lost consciousness and feel well, a quick medical check with a normal 12-lead electrocardiogram (ECG) rules out delayed heart rhythm danger.
Why is household Alternating Current (AC) more dangerous than Direct Current (DC) at the same voltage?
Household alternating current oscillates back and forth at 50 or 60 cycles per second (50/60 Hz), which stimulates human skeletal muscle fibers into a continuous, locked tetanic spasm ("no-let-go" phenomenon). Because the forearm flexor muscles are stronger than the extensor muscles, the victim's hand clamps tightly around the live wire, vastly increasing the duration of current flow and internal tissue cooking. In addition, 50/60 Hz AC repeatedly strikes the heart's vulnerable repolarization window, triggering ventricular fibrillation at three to five times lower current than DC.
Is it safe to use a wooden broomstick or dry tree branch to push a downed overhead power line off someone?
No, never attempt to use a wooden broomstick, tree branch, plastic pipe, or rubber gloves to move an overhead power line or any high-voltage wire (>1,000 volts). Household non-conductive tools only insulate against low-voltage household current (110 V to 240 V). At distribution voltages of 4,000 to 35,000 volts, electricity arcs effortlessly through the air and travels down microscopic moisture and resin pathways in wood or plastic directly into the rescuer, killing both people. Always stay 10 to 20 meters (33 to 65 feet) away and wait for the electric utility company to de-energize the line.
Why do I have to shuffle or hop with both feet together near a downed power line even if I am not touching the wire?
When a live high-voltage wire touches the earth, electricity radiates outward through the soil in concentric rings of decreasing voltage, like ripples in a pond. If you walk normally, your front foot lands on a ring of one voltage while your back foot touches a ring of a different voltage. That voltage difference between your feet (step potential) forces high-amperage current to shoot up one leg, through your pelvis and heart, and down the other leg. Keeping both feet pressed tightly together and shuffling or hopping ensures both feet stay at the exact same electrical potential so no circuit forms through your body.
Why does an electrical shock victim need to go to the emergency room if their skin only has a tiny pinpoint burn?
Electrical injuries follow the "iceberg effect," where 95 percent of the damage occurs out of sight deep inside the body. Because bone has the highest electrical resistance of any tissue, current traveling through an arm or leg heats the bone to extreme temperatures, cooking the deep muscle layers wrapped around the bone while leaving the outer skin looking nearly normal. This deep muscle destruction can rapidly cause limb-threatening compartment syndrome and release muscle proteins (myoglobin) that cause acute kidney failure within hours.
What should a pregnant woman do if she receives a minor household electric shock?
Any pregnant person who receives an electric shock from a household outlet, appliance, or faulty cord, especially if the current entered the hand and grounded through the feet, should go to the emergency department or obstetrical triage unit immediately, even if she feels completely unharmed and has no skin burns. Amniotic fluid and the fetal circulation offer very low electrical resistance, meaning a small current that barely tingles the mother's hand can pass directly through the uterus and affect the baby's heart rate or placenta.
Gid yu jëm ci loolu¶
- Cardiopulmonary resuscitation (CPR) and AED
- Burns: classification and first aid
- Safara ak limyéer yu kuuraŋ
- Thunderstorms and lightning safety
- Xool deret ju metti
- Nimero telefonu jafe-jafe ci réew mu nekk
Saytu nañu ay balluwaay¶
- American Heart Association (AHA, United States) and International Liaison Committee on Resuscitation (ILCOR): Guidelines for Cardiopulmonary Resuscitation and Emergency Cardiovascular Care (Special Circumstances of Resuscitation: Electrical Injury and Lightning)
- European Resuscitation Council (ERC): Guidelines on Cardiac Arrest in Special Circumstances , Electrocution and Lightning Strike
- Occupational Safety and Health Administration (OSHA, United States) and National Institute for Occupational Safety and Health (NIOSH / CDC, United States): Electrical Safety, Step Potential, and Arc Flash Trauma Directives
- American Burn Association (ABA, United States): Advanced Burn Life Support (ABLS) Clinical Practice Guidelines for Electrical and Lightning Injuries
- National Health Service (NHS, United Kingdom) and St John Ambulance (United Kingdom): First Aid Protocols for High-Voltage and Low-Voltage Electric Shock