Markaziy changyutgich yoki kiyim quritgich kuchaytirgichi ventilyatori devor ichidagi yong'in: metall plyonkali egiluvchan kanalning kuyishi va kirish panelini bo'g'ish¶
Emergency numbers differ by country. This page uses 911, the number for the United States and Canada. Many other countries use 112, 999, or another number. Find the number for your country.
Kiyim quritish moslamasining egzoz kanali, shiftga yoki devorga o'rnatilgan ikkinchi darajali quritgich kuchaytirgichi yoki markaziy vakuumli PVX/metall assimilyatsiya quvuri yashirin devor bo'shlig'idagi siqilgan tsellyuloza tuklarini yondirganda, siz xuddi o'sha yashirin yong'inga o'xshab tez kuchayib borayotgan **olovga duch kelasiz. devor ramkasi. Milliy yong'indan himoya qilish assotsiatsiyasi (NFPA) va Amerika Qo'shma Shtatlari Yong'in boshqarmasi (USFA) ma'lumotlariga ko'ra, tolali tuklar to'plamini tozalamaslik Qo'shma Shtatlardagi 15 970 yillik kiyim-kechak quritgich yong'inlarining taxminan 34 foizini tashkil qiladi va bu xavf zamonaviy ko'p qavatli shaharchalar va binolarning ichki qismidagi kir yuvish xonasining metrlari bo'lgan kvartiralarda ko'payadi 15 (25 dan 50 futgacha) tashqi devordan. Nam havoni uzoq masofadan pastga tushirish uchun quruvchilar 100 millimetrli (4 dyuymli) motorli in-line kanalli kuchaytirgich ventilyatorlarni ship tagliklari yoki gipsokarton kovaklariga o'rnatadilar. Yupqa nam paxta, polyester va uy hayvonlari soch tolalari birlamchi tuklar pardasini chetlab o‘tib, kuchaytirgich fanining 60°C dan 85°C (140°F dan 185°F) dvigatel korpusi va pervanel pichoqlarini qoplaganida, rotor ushlanib qoladi, dvigatel o‘ramlari haddan tashqari qizib ketgan yoki cho‘g‘ bilan quyilgan havo oqimi ostidagi tuproqli isitish elementi ichidan isitiladi. kanal. Bundan ham yomoni, agar quritgich roʻyxatga kiritilmagan Mylar plastmassasi yoki yupqa akkordeon alyuminiy folga oʻtish shlangi bilan devorga ulangan boʻlsa, 400°C (752°F) lint yongʻin yupqa plyonka orqali **45 soniyadan kamroq vaqt ichida yonib, olovni toʻgʻridan-toʻgʻri kir yuvilgan polga va yogʻochga chiqarib yuboradi.
Hech qachon kiyim quritgich eshigini ochmang, quritgichning orqa qismidagi egiluvchan o'tish trubasini tortib olmang yoki ichkarida tuklar olovi yonayotganda issiq gipsokartonni yirtib tashlamang; To'satdan 21 foizli xona kislorodining och qolgan, yonayotgan tuklar trubasiga tushishi kanal teshigidan chiqib ketadigan bir lahzada chayqaladigan shamollatuvchi olovni keltirib chiqaradi. Darhol hammani uydan evakuatsiya qiling, kir yuvish xonasining eshigini orqangizdan yoping va mahalliy aholiga qo'ng'iroq qiling favqulodda raqamlar (AQSh va Kanadada 911 ta, Buyuk Britaniyada 999 ta, Yevropa Ittifoqi boʻylab 112 ta va Avstraliyada 000 ta) tashqaridan. Tegishli qurilma, chodir va elektr yong'inga oid favqulodda vaziyatlar uchun bizning qo'llanmalarimizga murojaat qiling chordoqdagi yong'in, egzoz ventilyatorining haddan tashqari qizishi va quritish moslamasining yong'inga chiqishi, kiyim quritish moslamasi isitish elementi korpusga ulangan, havo paxmoq ustida qiziydi va tuklar yonadi, qurilma yong'inlari, va elektr olovi va uchqunlar.
Buni hozir qiling¶
Agar kir yuvish xonangiz devoridan, ship tagidan, markaziy vakuumli idishdan yoki tashqi ventilyatsiya qopqog'idan qattiq yonayotgan paxta, yonayotgan plastmassa yoki kuygan soch hidini sezsangiz:
- Masofaviy paneldagi elektr quvvati va gaz ta'minotini zudlik bilan o'chiring, quritgich eshigini OCHMANG:
- Chekiladigan kirlarni tekshirish uchun quritgichning yuklash eshigini hech qachon tortmang; eshikni ochish yangi kislorodni to'g'ridan-to'g'ri o'ta qizib ketgan barabanga beradi va olovni yuzingizga uradi.
- To'g'ridan-to'g'ri asosiy elektr o'chirgich panelingizga o'ting va 30 amperli 240 voltli ikki qutbli quritgichni, kanal ichidagi kuchaytirgich fanini** (yoki gaz quritish dvigateli) oziqlantiruvchi 15 amperli 120/230 voltli avtomatik o'chirgichni va markaziy elektr to'xtatuvchining quvvat blokini **20 amperli **kuum.
- Nima uchun kuchaytirgich fanini to'xtatuvchini o'chirish juda muhim: Avtomatlashtirilgan quritish kanali kuchaytirgich fanini differensial bosim o'tkazgichi yoki oqimni sezuvchi o'rni ishga tushiradi. Quritgichni o‘chirganingizdan keyin ham o‘rnatilgan 5-10 daqiqalik kechikish taymeriga ega booster fan 2500 rpm tezlikda ishlashni davom ettiradi va to‘g‘ridan-to‘g‘ri temirchining ko‘rigi kabi shift ustunlaridagi yonib turgan tuklar olovi orqali majburiy kislorodni pompalaydi.
- Agar sizda tabiiy gaz yoki propanli quritgich bo‘lsa, quritgich orqasidagi chorak burilishli guruch gaz o‘chirish klapanini (yoki kir yuvish xonasi tutunli bo‘lsa, gaz manifoldu/metridagi) OFF (90 daraja perpendikulyar) holatiga burang.
- Chekish uchun quritgich orqasidagi egiluvchan o‘tish shlangini hech qachon ajratmang:
- 100 millimetrli (4 dyuymli) metall kanal tizimi ulangan va yopiq bo'lib qolsa, quvur ichidagi momiq olovi qisman silindrsimon metall trubka ichida saqlanadi va uning mahalliy kislorod ta'minotini tezda iste'mol qiladi.
- Agar siz quritgichni devordan uzoqroqqa tortsangiz va o'tish trubkasini devor bo'limidan tortib olsangiz, 100 millimetrlik ochiq quvur xona havosini ichkariga tortadigan va xona bo'ylab porlayotgan tuklar cho'g'ini portlatib yuboradigan gorizontal mo'ri mo'ri vazifasini bajaradi.
- Flex-Duct Burn-through yoki Booster kirish paneli alangasini ABC sinfidagi quruq kimyoviy o‘t o‘chirgich bilan o‘chiring:
- Faqat shiftdan tutun chiqmasa va orqangizdan to‘siqsiz chiqishingiz bo‘lsa:
- Agar quritgich orqasidagi yupqa folga yoki Mylar akkordeon shlangi orqali olov yonib ketgan bo‘lsa, idishning orqasidagi olov tagini UL/EN standartiga muvofiq ABC toifali quruq kimyoviy o‘t o‘chirgich bilan 2 metr (6,5 fut) masofadan supurib tashlang.
- Agar kir yuvish xonasi shiftidagi yoki shkaf devoridagi ilmali kuchaytirgich-ventilator xizmatiga kirish panelidan tutun chiqsa, avval kirish eshigini qo'lingizning orqa tomoni bilan his qiling. Agar metall yoki plastmassa kirish paneli qizib ketsa, uni yopiq holda qoldiring va darhol evakuatsiya qiling. Agar u salqin bo'lsa va faqat engil tutun ko'rinsa, xizmat ko'rsatish qulfini biroz sindirib, 2 soniyali ABC toifasidagi quruq kimyoviy kukunni kuchaytirgich fan korpusi qutisiga to'kib tashlang, so'ngra korpusni bo'g'ish uchun panelni yoping.
- Agar markaziy vakuumli devor kirish joyidan yoki garaj quvvati kanistridan tutun chiqsa, devordagi barcha kirish qopqoqlarini yoping:
- Markaziy vakuumli yong‘in foydalanuvchi iliq kamin kuli, sigaret qoldig‘i, gugurt boshi yoki metall silliqlash uchqunini changyutganda boshlanadi, bu uchqun soatiga 100 kilometr (60 mil/soat) tezlikda harakatlanadi, **50 millimetr (2 dyuym) devor ichidagi yupqa trubkaga yoki to‘g‘ridan-to‘g‘ri PVX trubkaga kirishi mumkin. devor ichidagi 90 graduslik tirsagida tolali soch tiqilib qolgan.
- Darhol markaziy changyutgichni o'chiring (turbina dvigatelining o'chirilishi cho'g'ni shamollatuvchi yuqori tezlikdagi havo oqimini to'xtatadi) va uydagi har bir bahorli devorga kirish klapan eshigi mahkam yopilganligini, uning rezina O-halqali qistirmalari muhrlanganligini tekshiring. PVX quvur tarmog'ining ikkala uchini muhrlab qo'yish devor ichidagi kislorodning tiqilib qolishiga olib keladi 30-60 soniya.
- Kir yuvish xonasi va garaj eshiklarini yoping va binoni evakuatsiya qiling:
- O'chirgichlar o'chirilgandan keyin sirt tutuni pasaygan bo'lsa ham, 26 kalibrli galvanizli po'lat quritish kanali yopiq yog'och polga yotqizilgan bo'shliqdan yoki devor tirgaklaridan o'tuvchi kanal **450 ° C dan 600 ° C gacha (842 ° F dan 1 112 ° F gacha) ** ichki tuklar yong'inida.
- Ko'pgina quruvchilar yonuvchi moddalar uchun **50 millimetr (2 dyuym) bo'sh joyni saqlab qololmaganligi sababli yoki quritish kanallarini shisha tolali izolyatsiyaga o'ramaganligi sababli, metall quvur tashqarisidagi yog'och ramka yoki kraft-qog'oz bug 'to'sig'i alangalanishi va shiftning ichida ko'rinmasdan yonishi mumkin.
- Termal tasvir kamerasi (TIC) yordamida butun devor va ship panjarasini skanerlash uchun yong'in bo'limiga qo'ng'iroq qiling:
- Mahalliyngizga qo'ng'iroq qiling favqulodda raqamlar uyning tashqarisidan.
- O't o'chiruvchilar quritgichning ventilyatsiyasi yoki markaziy vakuum trubasining kir yuvish xonasidan tomga/tashqi devor qopqog'igacha bo'lgan to'liq yo'lini infraqizil Termal Ko'rish Kamerasi (TIC) yordamida tekshirib ko'rishlarini kuting va ramka ichida yashirin 300°C (572°F) qizg'in nuqta yo'qligiga ishonch hosil qiling.
Nega in-line quritish moslamasi ventilyatori yonayotgan zig'ir uchqunini shiftingizdagi shamollatgichga aylantiradi
Quritgich tashqi devorga o'rnatilgan bir qavatli uylarda egzoz kanalining uzunligi atigi 1,5-2,5 metr (5-8 fut) ni tashkil qiladi. Zamonaviy ko'p qavatli uylar, kvartiralar va ikkinchi qavatdagi kir yuvish xonalarida quritgichning egzoz kanali ko'pincha tom yoki rom ustunidan chiqishdan oldin yopiq gipsokarton shiftlari ichidagi uchta 90 graduslik tirsak orqali **8 dan 18 metrgacha (26 dan 60 futgacha) ** yuradi. Kiyim quritish moslamasining standart g'ildiragi faqat **10,7 metr (35 fut) ekvivalent qattiq quvur qarshiligini engib o'tishi mumkinligi sababli (Xalqaro turar joy kodeksining IRC M1502.4.5.1 bo'limiga ko'ra), o'rnatuvchilar ikkinchi darajali **100 millimetr (4 dyuym) elektr kanalini shipning ventilyatorining yarmiga o'rnatadilar: v.
- Tuyg‘anish g‘ildiragining xavfi: Ventilyatorning yuqori oqimidagi ikkinchi darajali lint tutqich qutisi bilan himoyalanmagan bo‘lsa, ho‘l lint tolalar kuchaytirgich fanining orqaga egilgan pervanel pichoqlari va termal motor korpusini qoplaydi.
- Korong'i effekti: quritgich barabani yoki asosiy o'tish kanali ichida tuklar olovi alangalanganda quritgichning termal sug'urtasi (91°C / 196°F) puflaydi va quritgichni o'chiradi. Shu bilan birga, shiftdagi masofaviy kuchaytirgich fan o'zining bosim/taymer rölesi bo'yicha ishlashda davom etadi, quritkichning orqa qismidan alangani so'rib oladi va shift bo'shlig'idagi yonayotgan zig'ir to'shagidan bosim ostida kislorod oqimini o'tkazadi, yupqa kanallar orqali tez eriydi va yog'och pol ustunlarini yondiradi.
Qaror daraxti: devor ichidagi quritgichning shamollatgichini, kuchaytirgich fanini yoki markaziy vakuumli olovni ishga tushirish¶
flowchart TD
Start["Devor ichidagi kanaldagi yong'inda favqulodda vaziyat: quritgichning shamollatgichidan, ship kuchaytirgichidan yoki markaziy vakuumdan yonayotgan tuklar/plastik hid yoki tutun"] --> KillPower["1-QADAM: MASALIQ QUVVATNI VA HAVO OQIMINI O‘CHISH: 1. Quritgich eshigini ochmang yoki shamollatuvchi shlangni devordan tortib olmang 2. 30A quritgich to‘xtatuvchisi, 15A kuchaytirgich fan o‘chirgich va 20A markaziy elektr to‘sarni o‘chirib qo‘ying 3. Qattiq tutun kirmasa, gaz klapanini o‘chiring."]
KillPower --> SystemType{"Qaysi kanal tizimi chekish yoki qizib ketishdir?"}
SystemType -->|"KIYIMLARNI KUTITISH / IN-LINE BOOSTER FAN"| FlexCheck{"Quritgich orqasidagi o'tish shlangi orqali olov yondimi?"}
FlexCheck -->|"HA: folga/plastmassa shlangni yoqish"| SweepABC["O'TKAZIShNI MUVOFIQ QILING: • Quritgich eshigini yopilgan holda saqlang • ABC sinfidagi o't o'chirgich bilan orqa shlang alangasining tagini 2 m (6,5 fut) dan supurib tashlang • Kir yuvish xonasi eshigini yoping va zudlik bilan EVAKUAAT qiling."]
FlexCheck -->|"YO'Q: Devor ichidagi olov / Shiftni kuchaytirgich"| BoosterAccess{"Shiftni kuchaytiruvchi kirish panelidan tutun chiqyaptimi yoki devor quvib o'tyaptimi?"}
BoosterAccess -->|"Panelni qoplaydigan issiq yoki og'ir tutun"| EvacNow["Yashirin tuzilmaviy quvg'in yong'inlari: • Issiq kirish panelini ochmang yoki gipsokartonga kesmang (kislorod qo'shadi) • Tutun bo'lishi uchun kir yuvish xonasi eshigini yoping • Barcha yo'lovchilar va uy hayvonlarini evakuatsiya qiling; 911/999/112 raqamiga qo'ng'iroq qiling"]
BoosterAccess -->|"Panelni faqat sovuq va engil tutun"| PuffABC["KIRISH PANELINI BO‘LASH: • Yoriqni kuchaytiruvchi xizmat ko‘rsatish lyugi 5 sm (2 dyuym) • ABC toifasidagi quruq kimyoviy moddani ventilyator korpusiga 2 soniya davomida to‘kib tashlang • Kirish lyukini qayta yoping, kir yuvish xonasi eshigini yoping va yong‘in bo‘limi TIC skanerlash uchun evakuatsiya qiling."]
SystemType -->|"MARKAZIY VAKUUM Devor ichidagi trubka / kanistr"| VacTriage["MARKAZIY VAKUUM KO'R / TIQALIK TRIAYI: • Devorga kirish joyidan olinadigan 9 m shlangni ajratib oling va BARCHA devorga kirish qopqoqlarini yopib qo'ying • Barcha kirish joylarini muhrlab qo'ying + motorni o'chiring 50 mm PVX kislorod trubkasi • Garaj/podvaldagi po'lat yig'ish idishini eshikdan tekshiring."]
VacTriage --> CanisterHot{"Garajning markaziy vakuumli qutisi chekadimi yoki yonadimi?"}
CanisterHot -->|"HA: Canister sumkasi / qoldiq yong'in"| CanisterABC["YUKLASH CHOLASINI OCHISHMANG: • Pastki axloqsizlik chelakining qulfini ochishda yonayotgan kul/lint ustiga 21% kislorod to'kiladi • ABC o't o'chirish moslamasini kirish porti orqali to'kib tashlang yoki o't o'chirish bo'limini kuting."]
CanisterHot -->|"YO'Q: Smolder devor tirsagida qamalgan"| EvacNow
SweepABC --> EvacNow
PuffABC --> EvacNow
Yashirin quritgich kanalining anatomiyasi va devor quvib o'tish ichidagi kuchaytirgich fanining olovi¶
Qurilish me'yorlari nima uchun kiyim quritgichining egzoz tizimining har bir millimetrini qat'iy tartibga solayotganini tushunish uchun quritgichning isitish elementidan tom qopqog'igacha bo'lgan momiq yong'in yo'lini kuzating:
ANATOMY OF AN IN-WALL DRYER DUCT & BOOSTER FAN LINT FIRE
[LAUNDRY ROOM] [WALL CHASE / CEILING JOIST BAY] [EXTERIOR / ROOF]
+--------------+ || ||
| Clothes | || 4. IN-LINE BOOSTER FAN || 5. EXTERIOR HOOD
| Dryer | || (Motor seizes on damp lint || OR ROOF CAP
| | || OR fans flames like bellows) || (Illegal mesh
| [Heating | || +-----------+ || bird screen
| Element] | || ==============>| (Impeller)|==========> || plugs 100%
| | | || // +-----------+ || with lint)
| v | 1. FOIL || // * ||
| [Blower]====>| TRANSITION || // 2. SHEET-METAL | ||
+--------------+ DUCT ||// SCREWS IN PIPE [Access Hatch] ||
(Thin Mylar || (Protruding tips in Drywall Ceiling ||
or foil || snag wet lint ||
melts at || into a 10-cm ||
150-300°C) || fire plug) ||
Yashirin quritgichni ta'qib qilish yong'inlariga sabab bo'lgan 5 ta kod buzilishi¶
- Noqonuniy oq vinil, mylar folga yoki quritgich orqasidagi yupqa akkordeon alyuminiy o'tish shlangi:
- UL 2158A (Kiyim quritish moslamasi o‘tish kanali uchun standart) va Xalqaro turar joy kodeksi (IRC bo‘limi M1502.4.3) bo‘yicha UL 2158A ro‘yxatiga kiritilgan yarim qattiq alyuminiy kanal yoki og‘ir devorli folga o‘tish kanalining faqat bitta bo‘lagi 8 metrdan ortiq quruq va 2 metrdan oshmasligi kerak. O'tish kanali HECH QACHON devor, pol yoki ship bo'shlig'iga yashirilmasligi kerak.
- Mylar qatlamli folga shlanglari 150°C dan 250°C gacha (302°F dan 482°F gacha) haroratda eriydi va yonadi, 30-45 soniya ichida yonib ketadi va to'g'ridan-to'g'ri quritgich orqasida olov chiqaradi.
- Qattiq egzoz kanallarining bo'g'inlariga o'rnatilgan lavha-metall vintlar:
- IRC bo'limi M1502.4.2 ostida 100 millimetrli (4 dyuymli) qattiq galvanizli yoki alyuminiy quritgich quvurlarining qismlarini **metall vintlardek yoki trubaning ichki qismiga 3,2 millimetrdan (0,125 dyuym) ko'proq chiqadigan perchinlar bilan birlashtirish qat'iyan man etiladi.
- Yashirin ship tirsagi ichidagi har bir chiqadigan vint uchi ho'l paxta tolasini o'tkazib yuboradigan tikanli baliq ilgagi kabi harakat qiladi va devor quvib ichida zich 2 dan 5 kilogrammgacha (4,4 dan 11 funtgacha) quruq tsellyuloza bo'lagini hosil qiladi. Bo'g'inlar UL 181B-FX alyuminiy folga tasmasi yordamida tashqi tomondan mahkamlanishi kerak (kauchuk yopishtiruvchi quriydigan va yonib ketadigan hech qachon standart kulrang mato "yog'li lenta" emas).
- Ikkilamchi tuklar tutqichisiz himoyalanmagan in-line quritgich kuchaytirgichlari:
- UL 705 (Qo'shimcha SC: Quritish kanalining quvvatli shamollatgichlari / DEDPV) va IRC bo'limi M1502.4.4 bo'yicha har qanday in-line quritgich kuchaytirgichi ventilyatori maxsus UL 705 DEDPV ro'yxatiga kiritilgan bo'lishi kerak (**65°C / avtomatik havo o'tkazmaydigan, 150°C haroratda ishlay oladi. kir yuvish xonasi devoridagi issiqlik uzilishi va vizual nosozlik indikatori) va devor yoki shiftdagi doimiy olinadigan kirish paneli orqasiga o'rnatilishi kerak.
- Ko'pincha ustalar quritish moslamasini kuchaytirish uchun yopiq gipsokarton shiftlari ichiga arzon plastik hammom/chodirli inline fanatlarni o'rnatadilar. 6 oy ichida lint plastik motor korpusini o'rab oladi va yonadi.
- 2x4 o‘lchamdagi tirsakli devorlar va 90 graduslik tirsaklardagi maydalangan oval kanallar:
- Har bir o'tkir 90 graduslik metall tirsak quritgich kanaliga 1,5 metr (5 fut) ekvivalent ishqalanish uzunligini qo'shib, havo oqimidan og'ir ho'l tuklar to'planadigan girdok zonasini hosil qiladi.
- Tashqi parranda pardasi yoki tom/devor qopqog‘idagi sim to‘r:
- IRC Bo'limi M1502.3 ostida, ekranlar yoki sim to'rlar HECH QACHON kiyim quritgich egzoz chiqarish qopqog'ining tashqi qopqog'iga o'rnatilmasligi kerak, chunki 6 millimetr (0,25 dyuym) apparat mato pardasi bo'ylab nozik tuklar bir necha hafta ichida egzoz trubkasini muhrlab, isitish elementini 100 foiz yopib qo'yadi. Faqat gravitatsion damper qopqog'i yoki panjur qopqog'idan (yoki to'liq ochiladigan bitta katta ochiladigan zararkunandalardan himoyachi) foydalaning.
Taqqoslash jadvali: 4 ta quvur materiallari bo'yicha yashirin kanaldagi yong'in harakati¶
| Kanal materiali devor ichidagi / quritgichning orqasida | Kod holati (IRC M1502 / NFPA 211 / UL 2158A) | Erish / yonish harorati | Lint yong'in paytida yong'inni o'chirish harakati |
|---|---|---|---|
| 1. Oq vinil yoki mylar-laminatsiyalangan folga akkordeon shlangi | **100% NOQONUN ** quritgich orqasida ham, ichki devorlarda ham. | 120°C dan 200°C gacha (248°F dan 392°F gacha) (Olovli plastmassa yonadi va tomiziladi). | 15 dan 30 soniyagacha yonib, kir yuvilgan polga alangali erigan plastmassani tomizadi va zaharli vodorod xlorid (HCl) gazini chiqaradi. |
| 2. Thin Unlisted Aluminum Foil Accordion Flex Duct | QONUNIYSIZ devor/shipning ichki qismi; behind dryer only if specifically UL 2158A-listed (\(\le 2.4\text{ m / 8 ft}\)). | 350°C dan 450°C gacha (662°F dan 842°F gacha) (Yupqa 0,025 mm folga oksidlanadi va yirtilib ketadi). | Chuqur akkordeon tizmalari massiv tuklar cho'ntaklarini ushlab turadi; when crushed behind the dryer, a lint fire melts pinholes through the thin foil in 45 to 90 seconds. |
| 3. Yarim qattiq gofrirovka qilingan alyuminiy kanal | FAQAT quritgich orqasida UL 2158A oʻtish kanali sifatida ruxsat etiladi (\(\le 2.4\text{ m / 8 ft}\)); yashirin devorlar ichida taqiqlangan. | 660°C (1220°F) (Sof alyuminiy qotishmasining erish nuqtasi). | **5 dan 12 minutgacha ** yonib ketishga chidamli bo'lib, quvvatni o'ldirish va bo'g'ish uchun vaqt beradi, lekin momiqning doimiy yonishi 650°C dan oshsa, yumshaydi va osadi. |
| 4. Silliq devorli 26-gauge yoki 28-gauge qattiq galvanizli po'lat quvur | Majburiy KOD STANDART Devorga, polga va chodirga quritgichning barcha yashirin egzoz quvurlari uchun (IRC M1502.4.1). | 1370°C dan 1510°C gacha (2500°F dan 2750°F gacha) (uglerodli po'latning erish nuqtasi). | Quvur ichida jismonan yong‘in paydo bo‘ladi, agar bo‘g‘inlar UL 181B-FX folga lentasi bilan yopishtirilgan va yog‘och ramkalar orasidagi bo‘shliqlar saqlanib qolgan bo‘lsa, erimaydi. |
Markaziy vakuumli devor ichidagi PVX quvurlari yong'inlari: nega kamin kulini changyutkichdan tozalash halokatli¶
Kiyim quritgichdan (issiq havoni tashqariga chiqaradi) farqli o'laroq, markaziy vakuum tizimi garaj yoki podvalda o'rnatilgan yuqori quvvatli 1500-2400 vattli tangensial aylanma turbinali dvigateldan foydalanadi havoni soniyasiga **30-45 metr tezlikda (65-45 m/saat 0-10-10-000 m/s) ichkariga tortish uchun. (2 dyuym) yupqa devorli ASTM F2158 PVX vakuum trubkasi ichki devorlaringizga yashiringan:
HOW A CENTRAL VACUUM IN-WALL PVC PIPE FIRE DEVELOPS AND IS SMOTHERED
[LIVING ROOM WALL INLET] [IN-WALL 90° SWEEP ELBOW] [GARAGE POWER UNIT]
1. User vacuums "cold" fireplace ash 2. 100-MPH airflow fans ember 3. IF MOTOR LEFT ON:
containing a hidden 500°C ember into a hair/carpet-fiber clog PVC melts at 140°C
|| at a 2-inch PVC elbow & canister explodes
vv ||
[Snap Inlet Door SHUT] ===========================>(**)<==================== [Flip Breaker OFF]
(Blocks incoming air) (Starved of oxygen in (Stops turbine suction)
sealed pipe -> Dies in 45 s)
- Yong'in qanday boshlanadi:
- Uy egasi kul sovuq deb o'ylab, pechka yoki kamin atrofidagi o'choqni tozalayapti (yoki tushgan gugurt, isiriq konusi yoki Dremel uchqunini changyutmoqda).
- 50 millimetr (2 dyuym) PVX devor trubasiga so'rilgandan so'ng, 100 milya / soat tezlikdagi majburiy havo oqimi mikroskopik ko'mir cho'g'ida yuqori o'choq kabi ishlaydi.
- Agar cho'g' garaj yig'ish idishigacha bo'lgan yo'lni bosib o'tsa, u quruq gilam paxmoqlari, qog'oz changlari va sochlarga o'ralgan **20 litrli (5 gallon) chelak ichiga tushib, po'lat yoki plastmassa kanistrni 60 soniya ichida do'zaxga aylantiradi.
- Agar cho'g' 90 graduslik PVX tirsagiga** tiqilib qolgan **soch to'pi va tish pichog'i tiqilib qolgan qismiga devorning yarmigacha tiqilib qolsa, yonayotgan tiqin tezda yumshaydi va 1,8 millimetr (0,07 dyuym) PVX quvur devori (u **80°C / **80°F /176°S haroratda yumshaydi) orqali yonib ketadi. 734°F), yog'och devor tirgaklarini olovga qo'yish.
- Markaziy vakuum liniyasidagi yong'inni darhol qanday bo'g'ish kerak:
- 1-qadam: Moslashuvchan vakuum shlangini devor portidan ajratib oling, shunda bahorli metall yoki plastmassa devorga kirish qopqog'i uning rezina qistirmasiga mahkam yopishib qoladi.
- 2-qadam: Elektr paneliga (yoki garaj quvvat tugmasi) yuguring va markaziy vakuum quvvat blokini o'chiring.
- Nima uchun bu ishlaydi: Markaziy vakuumli PVX quvurlari har bir devor kirish joyidan yig'ish idishigacha bo'lgan havo o'tkazmaydigan erituvchi bilan payvandlanganligi sababli u 25 kilopaskal (100 dyuymli suv ustuni) vakuum assimilyatsiyasini ushlab turishi mumkin, dvigatelni o'chiradi va barcha devorga kirish klapanlarini yopib qo'yadi **3 litr havo-metrdan kam bo'lgan trubka ichida ** 330. Havo oqimi bo'lmasa, PVX trubkasi ichidagi yonayotgan tiqin qolgan kislorodni **30-45 soniya ichida iste'mol qiladi ** va o'z-o'zidan o'chadi.
- 3-qadam: Garajdagi chekish uchun markaziy vakuum kanistrining pastki kir paqirini hech qachon ochmang va devor yo‘lini va garaj blokini termal tasvir kamerasi bilan tekshirish uchun o‘t o‘chirish bo‘limiga qo‘ng‘iroq qiling.
Nima uchun siz hech qachon issiq quritish moslamasiga yoki markaziy vakuumli devorga suv tushmasligingiz kerak
Devor ichidan yonayotgan tuklar hidini sezadigan uy egalari ba'zan bog 'shlangini tashqi quritgichning shamollatuvchi qopqog'iga yopishtirishga yoki markaziy vakuumli devor portiga suv quyishga harakat qilishadi. Hech qachon quvvat olayotgan yoki issiq qurilma kanaliga suv quymang: - Kiyim quritgichda suv qiyalik 100 millimetrli (4 dyuymli) metall kanal orqali to'g'ridan-to'g'ri orqa 240 volt / 5000 vattli nikromli isitish elementi korpusi va klemens blokiga (yoki 120/230 voltli liniyadagi kuchaytiruvchi fan motoriga) oqib o'tadi va bu to'g'ridan-to'g'ri qisqa tutashuv va metall quvur liniyasida kuchlanish hosil qiladi. - Bunga qo'shimcha ravishda, ho'l zig'ir og'ir, betonga o'xshash papier-mache tiqinga aylanadi, bu quvurni to'liq to'sib qo'yadi va bug 'issiqligini devor ichidagi quvg'in ichida ushlab turadi.
Favqulodda vaziyatdan keyingi tekshirish va doimiy yong'inga qarshi kanallarni tiklash¶
Tuklar haddan tashqari qizib ketganidan yoki kanaldagi yong‘in sodir bo‘lgandan so‘ng, sertifikatlangan quritgichning chiqindi chiqarish bo‘yicha mutaxassisi (masalan, CSIA sertifikatlangan quritgich chiqarish bo‘yicha mutaxassis [C-DET]) yoki litsenziyaga ega HVAC pudratchisi to‘liq kamerali tekshiruvdan o‘tmaguncha yoki markaziy changyutgichni boshqa hech qachon ishlatmang**:
- Ichki yong'inga duchor bo'lgan barcha yashirin kanallarni almashtiring:
- 26 kalibrli galvanizli po‘lat quritgich kanali ichida lint yong‘in sodir bo‘lganda, 600°C (1112°F) issiqlik himoya ruxli galvanizatsiya qoplamasini yoqib yuboradi, yopishtiruvchi tikuvlarni burishtiradi va tashqi **UL 181B alyuminiy folga elimini eritadi.
- Faol alanga olib ketayotgan har qanday kanal qismi olib tashlanishi va yangi 100 millimetr (4 dyuym) qattiq 26 kalibrli galvanizli po'lat quvur bilan almashtirilishi kerak, uning o'rniga erkak qiyshiq uchlari **havo oqimi yo'nalishi bo'yicha pastga qaratiladi (shuning uchun tuklar xom metall labga yopishgandan ko'ra, tizza bo'g'inlari ustida silliq oqadi).
- Istalgan in-line kuchaytirgich fanining yuqori oqimiga ikkinchi darajali devorga o‘rnatilgan tuklar tutqichni o‘rnating:
- Agar quritgichingiz ish vaqti 10,7 ekvivalent metrdan (35 fut) oshsa va UL 705 DEDPV ro‘yxatiga kiritilgan kuchaytiruvchi fan kerak bo‘lsa, kanal devorga kirishdan oldin to‘g‘ridan-to‘g‘ri quritgichning tepasiga aniq eshikli ikkilamchi devorga o‘rnatiladigan to‘rli tuklar tutqich qutisini o‘rnating. Ushbu ikkilamchi ekranni haftada bir marta tozalash, qochib ketgan tuklarning 99 foizi yashirin ship kuchaytirgich faniga etib borishini oldini oladi.
- Quritish moslamasi orqasidagi ulanishlarni qattiq periskop qutisiga yoki quritgichning o‘rnatilgan shamollatish qutisiga yangilang:
- Ko'pincha o'tish shlangi yong'inlari uy egalari quritgichni devorga mahkam itarib, egiluvchan shlangni zig'irchalarni ushlab turuvchi egilgan S-egri chiziqqa ezib tashlashi sababli boshlanadi. 2x4 yoki 2x6 o'lchamdagi kir yuvish devori bo'shlig'iga cheklangan po'lat quritgich qutisini o'rnating, shunda quritgich quvurni bukmasdan devorga tekis surishi mumkin.
Devordagi quritgichning shamollatgichi yoki kuchaytirgich ventilyatoringiz zig'irchaga ulanganligini 10 soniya ichida qanday aniqlash mumkin
Kiyim quritgichingizni bo'sh baraban bilan High Heat rejimiga yoqing, tashqi devorga yoki tom yopish qopqog'iga boring va qo'lingizni yoki ro'molchani egzoz damperi oldida ushlab turing (yoki sizda DEDPV kuchaytirgich faningiz bo'lsa, devorga o'rnatilgan bosim nosozlik indikatori chiroqini tekshiring). 100 millimetrli (4 dyuymli) toza quritgich kanali kuchli 4,5-6,0 metr/sekund (900-1200 fut/daqiqa) issiq shabadani chiqaradi, bu esa damper qopqoqlarini 45-90 graduslik burchak ostida keng ochadi. Agar tashqi amortizator 5 millimetrga zo‘rg‘a ochilib qolsa, quritgich shkafi tepasi teginish uchun issiq bo‘lsa yoki vanna sochiqlarining yuki **45-50 daqiqadan ko‘proq quritilishi kerak bo‘lsa, devorga o‘rnatilgan kanal yoki kuchaytirgich ventilyatoringiz 70-90 foiz tuklar bilan tiqilib qolgan va yong‘in xavfi mavjud. Quritgichdan foydalanishni darhol to'xtating va aylanma cho'tka bilan butun kanalni uchidan oxirigacha tozalang.
Mintaqaviy quritgich egzoz kodlari, kuchaytirgich fan standartlari va favqulodda kontaktlar¶
| Mintaqa / mamlakat | Favqulodda raqam | Quritgichning chiqindisi va kuchaytirgich fanining standartlari | Majburiy kanal materiali, uzunligi va vida qoidalari |
|---|---|---|---|
| Amerika Qo'shma Shtatlari | 911 | Xalqaro turar joy kodeksi (IRC Section M1502), NFPA 211, UL 2158A (O‘tish kanallari) va UL 705 Supplement SC (DEDPV Booster Fans) | IRC M1502.4: Yashirin kanallar silliq devorli qattiq metall (min. 0,4 mm / 28 kalibrli po'lat) bo'lishi kerak; maksimal uzunlik 10,7 m (35 fut) minus 1,5 m (5 fut) 90° tirsak uchun; > 3,2 mm (⅛ dyuym) chiqadigan vintlar yo'q; tashqi ekranlar yo'q; kuchaytirgich fanatlari kirish paneli bilan UL 705 DEDPV ro'yxatida bo'lishi kerak. |
| Kanada | 911 | Kanada Milliy Qurilish kodeksi (NBC 9.32 / 6.2 bo'limi) va CSA C22.2 № 113 (DEDPV muxlislari) | Yashirin quritgichning egzoz kanallari qattiq silliq devorli metall lavha bo'lishi kerak; vinil/folga kanallari taqiqlangan; tashqi davlumbazlarda hasharotlar/qush to'rlari bo'lmagan, orqaga tortish damperi bo'lishi kerak. |
| Birlashgan Qirollik | 999 yoki 112 | Qurilish qoidalari tomonidan tasdiqlangan F hujjati (ventilyatsiya) & BS EN 61121 / Buyuk Britaniya yong'inga qarshi xizmati quritgich bo'yicha ko'rsatmalar | Iloji bo'lsa, 3 metr (10 fut) ostida qattiq silliq teshikli kanallarni tavsiya eting; plastik qoplamali quritgichlarda ishlab chiqaruvchining mahsulotini qaytarib olishini tekshiring; kommutatsiyalangan ikki qutbli eritilgan shnur yoki vilka orqali izolyatsiya qiling. |
| Yevropa Ittifoqi | 112 | EN 61121 (maishiy foydalanish uchun quritgichlar) va EN 13180 (Binolar uchun ventilyatsiya: kanallar) | Bino bo'linmalaridan o'tadigan, yong'inga to'xtatilgan penetratsiyali shamollatiladigan quritgichlar uchun A1/A2 sinfidagi yonmaydigan metall egzoz kanallarini talab qiladi. |
| Avstraliya va Yangi Zelandiya | 000 (AU) / 111 (NZ) | AS 1668.2 (Binolarda mexanik shamollatish) va AS/NZS 60335.2.11 (Kiyim quritgichlarning xavfsizligi) | Ko'p blokli/yashirin ship yo'nalishlari uchun silliq teshikli metall kanallarni, har qanday ichki egzoz ventilyatoridan oldin tozalanishi mumkin bo'lgan lintlarni filtrlashni va foydalanish mumkin bo'lgan tekshirish lyuklarini talab qiladi. |
Tez-tez beriladigan savollar¶
Nega quritish moslamasidagi yong'in paytida liniyadagi quritgich kuchaytirgichining o'chirgichini darhol o'chirish kerak?¶
Kiyim quritgich yoki uning egzoz kanalida tuklar yong'in boshlanganda, quritgichning ichki yuqori chegarali termal sug'urtasi (taxminan 91 daraja Selsiy / 196 daraja Farengeyt) odatda eritiladi va quritgichni o'chiradi. Shu bilan birga, shiftga yoki devorga o'rnatilgan kanal ichidagi kuchaytirgich fan alohida 120 voltli yoki 230 voltli kontaktlarning zanglashiga olib keladi va havo bosimini o'zgartirish tugmasi yoki 5 dan 10 minutgacha kechikish taymeriga ega bo'lgan oqimni sezuvchi o'rni bilan boshqariladi. Agar siz asosiy paneldagi kuchaytirgich fanining avtomatik o'chirgichini O'CHIRmasangiz, bu fan shift ichida 2500 aylanish tezligida aylanib, quritgichning orqa qismidan alangani so'rib oladi va devor bo'shlig'ingiz ichidagi yonayotgan tuklar orqali bosim ostida yangi kislorod oqimini pompalanadi.
Chekish kiyimlarini quritgichning orqa qismidan moslashuvchan shamollatish shlangini tortib olish nima uchun xavfli?¶
100 millimetrli (4 dyuymli) metall o'tish shlangi quritgichning orqa tomoniga ham, devordagi chiqindi shlangiga ham (quritgich eshigi yopilgan va quvvat o'chirilgan holda) mahkamlangan bo'lsa, quvur ichidagi momiq yong'in muhrlangan metall silindr ichida saqlanadi, u erda kislorod tezda tugaydi va soviydi. Agar siz quritgichni devordan uzoqlashtirsangiz va ichkarida tuklar yonayotgan paytda shamollatish shlangini devor trubkasidan uzib qo'ysangiz, siz bir zumda 21 foizli kislorodni o'ta qizib ketgan to'shagiga yuborasiz va vertikal devorni ochiq mo'riga aylantirasiz, bu esa kir yuvish xonasi bilan dush paytida olovni to'g'ridan-to'g'ri uyingizning ramkasiga tortadi.
Nima uchun metall lavha vintlardek va tashqi qush pardasi kiyim quritgichining egzoz kanallarida noqonuniy hisoblanadi?¶
Xalqaro uy-joy kodeksi (IRC Section M1502) va NFPA 211 ga binoan, 100 millimetrli (4 dyuymli) quritgich quvurining bo'g'inlariga standart metall vintlarni burish taqiqlanadi, chunki qorong'i trubaning ichida chiqadigan o'tkir vint uchlari nam paxta va polyester tolalarni har bir yukga yopishtiradi, qattiq shiftni quradi. bo'shliq. Xuddi shunday, tashqi devor yoki tomning shamollatuvchi qopqog'i ustiga sim to'rli qush yoki kemiruvchi pardani o'rnatish noqonuniy hisoblanadi, chunki quritgichning nozik tuklari bir necha hafta ichida sim to'r bo'ylab gilamchalar bo'lib, egzoz chiqishini 100 foizga yopib qo'yadi va tuklar quritgichning isitish elementiga to'liq to'planishiga olib keladi. Kanal bo'g'inlarini har doim tashqi tomondan UL 181B-FX alyuminiy folga tasmasi bilan yopishtiring va ochiq havoda to'rsiz panjur yoki qanotli damperdan foydalaning.
Issiq kamin kulini tasodifan tozalagandan so'ng, markaziy vakuumli PVX devor trubkasi ichidagi yong'inni qanday to'xtatish mumkin?¶
Kamin kulidan yoki sigaret qoldig'idan yashiringan cho'g'i markaziy vakuumga so'rilsa, 50 millimetrli (2 dyuym) yupqa devorli PVX trubka ichidagi soatiga 100 kilometr (60 milya) havo oqimi cho'g'ni ventilyatorga aylantiradi, bu esa sochlarni to'plash yoki yoqib yuborishi mumkin. kanistr yonmoqda. Darhol devordan egiluvchan vakuumli shlangni ajratib oling, shunda prujinali devorga kirish eshigi rezina O-halqasiga mahkam yopiladi, uydagi barcha boshqa devor kirish qopqog'i yopilganligiga ishonch hosil qiling va garajdagi markaziy vakuum turbinasi uchun o'chirgichni o'chiring. PVX quvur tarmog'i havo o'tkazmaydigan tarzda yopishtirilganligi sababli, dvigatelning so'rilishini kesib, barcha kirish qopqoqlarini yopish quvur ichidagi deyarli nol kislorodni ushlab turadi va devor ichidagi cho'g'ni 60 soniya ichida bo'g'ib qo'yadi.
Ushbu qoʻllanma maʼlumot uchun moʻljallangan boʻlib, favqulodda yongʻin boʻlimiga javob berish yoki sertifikatlangan quritgich chiqarish boʻyicha mutaxassis (C-DET) yoki litsenziyaga ega HVAC/elektrik pudratchi tomonidan xizmat koʻrsatishni almashtirmaydi. Agar devor yoki shift bo'shlig'idan tutun chiqsa, har doim uyingizni zudlik bilan evakuatsiya qiling va Qizil Xoch yoki Sent-Jon tezyordamida yong'in xavfsizligi va birinchi yordam kursini o'ylab ko'ring.
Tegishli qo'llanmalar¶
- Chordoqdagi yong'in, egzoz ventilyatorining haddan tashqari qizishi va quritgichning shamollatilishi
- Kiyim quritish moslamasining isitish elementi korpusga ulangan, havoda qiziydi va tuklar yonadi
- Hammom egzoz ventilyatori chordoqdagi shamollatuvchi kondensatsiya yomg'iri va haddan tashqari qizib ketgan dvigatel olovi
- Qurilma yong'inlari
- Elektr yong'inlari va uchqunlari
- Uglerod oksidi va tutun inhalatsiyasida birinchi yordam
- Favqulodda raqamlar
Manbalar va rasmiy ko'rsatmalar¶
- Xalqaro Kodeks Kengashi (ICC): Xalqaro turar joy kodeksi (IRC bo'limi M1502: Kiyim quritish moslamasi egzozlari, kanal materiallari, maksimal ekvivalent uzunlik, o'tish kanallari va DEDPV kuchaytirgich faniga qo'yiladigan talablar).
- Underwriters Laboratories (UL): UL 2158A (Kiyim quritish moslamasi oʻtish kanali uchun standart) va UL 705 qoʻshimcha SC (Quvvatli shamollatgichlar / quritish egzoz kanali quvvat shamollatgichlari uchun standart - DEDPV).
- Milliy yong'indan himoya qilish assotsiatsiyasi (NFPA) va Amerika Qo'shma Shtatlari yong'in boshqarmasi (USFA / FEMA): * Uy elektr va kiyim quritgichining yong'in xavfsizligi hisobotlari va NFPA 211 (mo'rilar, kaminlar, shamollatgichlar va qattiq yoqilg'ida yonadigan asboblar)*.
- Amerikaning Bacalar xavfsizligi instituti (CSIA): Sertifikatlangan quritgich egzoz bo'yicha texnik (C-DET) qo'llanmasi: tuklar to'planishi fizikasi, havo oqimi tezligini sinovdan o'tkazish va kuchaytirgich faniga texnik xizmat ko'rsatish.