Skip to content

Ukhuseleko lwejenereyitha: ukuthintela ityhefu yecarbon monoxide kunye nomlilo

Amanani kaxakeka ayohluka ngokwamazwe. Eli phepha lisebenzisa u-911, inani laseMelika naseKhanada. Amanye amazwe amaninzi asebenzisa i-112, 999, okanye elinye inani. Fumana inombolo yelizwe lakho.

Iijeneretha eziphathwayo kunye nezokulinda zibonelela ngombane wobomi obungxamisekileyo ngexesha lezaqhwithi, izivunguvungu zeqhwa zasebusika, kunye nokucima umbane owenziweyo owandisiweyo, ukugcina izixhobo zonyango, iimpompo ze-sump, iinkqubo zokufudumeza kunye neefriji zisebenza. Nangona kunjalo, ukusebenza ngokungafanelekanga kwejenereyitha yenye yezona ngozi zibulalayo zasemva kwentlekele kwihlabathi liphela, ukubulala abantu abaninzi ngekhabhoni engabonakaliyo ye-carbon monoxide (CO) yokuphefumla, ukubangela imililo yepetroli edanyazayo ngexesha lokufakwa kwepetroli eshushu, kunye nokuntywila kubasebenzi bentambo yombane ngokubuyisela umbane ngokungekho mthethweni.

Yenza oku ngoku

  1. Misa ijenereyitha ngaphandle ubuncinane kwiimitha ezi-6 (iinyawo ezingama-20) ukusuka kwisakhiwo ngasinye: Beka iyunithi kwindawo evulekileyo ubuncinane kwiimitha ezi-6 (iinyawo ezingama-20) kude nendlu yakho, kumakhaya abamelwane, iigaraji, iishedi, kunye neveranda. Ungaze uqhube ijenereyitha ngaphakathi kwigaraji encanyathiselweyo okanye evalelweyo, indawo engaphantsi komhlaba, indawo yokukhwela umoya, indlela yokuphefumla, okanye ipatio egqunyiweyo, nokuba kukho iingcango okanye iifestile ezivulwe ngokubanzi.
  2. Jonga umbhobho wokukhupha umoya we-injini ezantsi kwaye kude kuzo zonke iindawo ezivulekileyo: Yalatha umbhobho we-muffler tail kude ngqo kwiifestile, iingcango, iiventi ze-soffit, iiventi zokomisa, kunye neziko elisebenza kakuhle kakhulu okanye i-heat-recovery ventilator (HRV) umoya omtsha ukuze imisinga yomoya ingakwazi ukuthwala iigesi zokukhupha ngaphakathi.
  3. Vavanya iialam zekhabhon monoksayidi esebenza ngebhetri kumgangatho ngamnye phambi kokuba uqalise: Cinezela iqhosha lovavanyo kwizichongi eziqinisekisiweyo, ezisebenza ngebhetri okanye ezixhaswe ngebhetri ekharbhon monoksayidi efakwe kuwo onke amanqanaba endlu yakho nangaphandle kwendawo yokulala. Ungaze uqhube ijenereyitha ngobusuku ngaphandle kokuba ii-alam ze-CO ezisebenzayo zisebenza ngaphakathi.
  4. Qhagamshela izixhobo ezisebenzisa umsebenzi onzima wegeyiji ye-10 okanye i-12-gauge yeentambo zangaphandle okanye utshintshiselwano: Xhaga izixhobo zombane ngqo kwizixhobo ezikhuselweyo ze-GFCI zejenereyitha usebenzisa ezisekelwe phantsi, iintambo zolwandiso lwangaphandle ezineentambo ezilinganiselwe kumthwalo (12 AWG okanye i-10 AWG edityanisiweyo yelayisenisi), okanye ufakele ilayisensi yombane edityanisiweyo mechanical breaker interlock.
  5. Ungaze uplage ijenereyitha kwindawo ephuma eludongeni okanye kwisokethi yokomisa (akukho sondlo): Ungaze usebenzise "intambo yokuzibulala" yamadoda amabini ukondla umbane kwisixhobo sasekhaya. I-backfeeding ithumela umbane we-240-volt ngasemva nge-transformer yakho yangaphandle, inyuse iye kuthi ga kwi-7,200 ukuya kwi-14,400 volts kunye nokubulala ngombane abasebenzi okanye abamelwane abaphantsi kwesitrato.
  6. Vala injini uze uyiyeke iphole kangangemizuzu eli-15 ukuya kwengama-20 phambi kokuba ugalele i-petroli: Cima yonke imithwalo yombane eqhagamshelweyo, cima i-injini yejenereyitha, uze ulinde imizuzu eli-15 ukuya kwengama-20 ukuze umbhobho wokuphuma uphole ngaphantsi kobushushu bokuvutha komphunga wepetroli phambi kokuba uvule isivalo sepetroli.

Ukuvula umnyango wegaraji akuyi kukusindisa kwi-carbon monoxide

Ungaze uqhube ijenereyitha ephathekayo ngaphakathi kwegaraji enocango lwebhayi luvuliwe, okanye ngaphantsi kwekhapoti eqhotyoshelweyo okanye uphahla lweveranda. I-aerodynamic wind eddies ejikeleze izakhiwo zenza iindawo zokufunxa ezinoxinzelelo olubi ngaphakathi kweigaraji ezivulekileyo ezitsala umsi ngasemva ngokusebenzisa amatywina angaphakathi ocango, i-drywall seams, kunye nejoists yesilingi ngqo kumagumbi okulala aphezulu, ivelisa i-carbon monoxide ebulalayo ye-1,000+ iinxalenye ngesigidi (ppm) ngaphantsi kwemizuzu eyi-15.


Ukusasazwa kwejenereyitha kaxakeka kunye nomthi wesigqibo sokhuseleko

Landela le tshati yokuqinisekisa ngenyathelo phambi kokuba uqalise nayiphi na i-petroli, ipropane, okanye i-diesel ephathekayo yejenereyitha ngexesha lokucima.

flowchart TD
    A["Ukumka koMbane kwenzeka: Lungisa iGenereyitha ephathwayo"] --> B{"Ingaba iyunithi ingaphandle kumhlaba owomileyo, othe tyaba >= 6 m (20 ft) kuzo zonke iindonga, iifestile, kunye neendawo zokungenisa umoya?"}
    B -->|"Hayi"| C["YIMA: Shutha iyunithi ubuncinci be-6 m (20 ft) ngaphandle kwaye ukhombe umbhobho wokuphuma umoya"]
    C --> B
    B -->|"Ewe"| D{"Ngaba kuyanetha okanye kunekhephu?"}
    D -->|"Ewe"| E["Phakamisa iyunithi nge-10 cm (4 ngaphakathi) kwiipava kwaye ufake i-canopy ebalekayo evulekileyo eqinisekisiweyo."]
    D -->|"Hayi"| F{"Ngaba ii-alam ze-CO ezixhaswa ngebhetri zivavanyiwe kwaye ziyasebenza kuwo wonke umgangatho?"}
    E --> F
    F -->|"Hayi"| G["Faka iibhetri ezintsha kwaye uvavanye ii-alam ze-CO phambi kokuba uqalise injini"]
    G --> F
    F -->|"Ewe"| H{"Uyidibanisa njani imithwalo yombane?"}
    H -->|"UTshintsho loTshintsho okanye i-Interlock"| I["Cima i-Main Utility Breaker kuqala, qhagamshela i-L14-30 / 14-50 intambo yokungena, qala injini, unike amandla iisekethe nganye nganye."]
    H -->|"Ngqo Extension Cords"| J["Qinisekisa i-12 AWG okanye i-10 AWG yangaphandle yeentambo ze-SJTW/SOOW, jonga iipronge zomhlaba, i-injini yokuqalisa, iplagi kumthwalo onzima wemoto kuqala"]
    H -->|"I-Wall Outlet / iSokethi yesomisi"| K["INKCAZELO ENGAKHO EMTHETHWENI NEYIFA: Yima ngoko nangoko kwaye utshintshele kwiintambo zokwandisa zangaphandle"]
    I --> L{"Ngaba ufuna ukugcwalisa ijenereyitha?"}
    J --> L
    L -->|"Ewe"| M["Khupha imithwalo, vala injini, linda i-15 ukuya kwimizuzu engama-20 ukuze uphole phambi kokuba ugalele amafutha"]

Ityhefu yeCarbon monoxide, i-emission physics, kunye nemigangatho yokubeka

I-Carbon monoxide (CO) yigesi eyityhefu engenavumba, engenambala, engenancasa, engacaphukisiyo eveliswa kukutsha okungaphelelanga kwamafutha asekelwe kwikhabhoni kuquka i-petroli, i-diesel, i-propane yamanzi (LPG), kunye negesi yendalo. Ngenxa yokuba izivamvo zomntu zingakwazi ukubona ikharbon monokside nakweyiphi na inxinaniso, amaxhoba adla ngokuphazama iimpawu zetyhefu zakwangoko (intloko ebuhlungu, ukuba nesiyezi, isicaphucaphu, nokozela) ngenxa yomkhuhlane oyintsholongwane, ityhefu ekutyeni, okanye ukudinwa sisiphango, alale phantsi ukuze aphumle, aze awele kwisiqaqa esingenakulungiseka.

Amazinga okukhutshwa okukhulu kweenjini ezincinci zokupholisa umoya

Ngokungafaniyo neemoto zanamhlanje zabahambi, ezisebenzisa i-computer-controlled closed-loop fuel injection and three-way catalytic converters ukunciphisa i-tailpipe CO ekhutshwayo ngaphantsi kwe-0.05 pesenti, ii-injini zejeneretha eziphathwayo zilula, ii-injini zejeneretha eziphathwayo zilula, ezipholiswe ngumoya omnye okanye ii-twin-cylinder engines ezisebenza kumxube otyebileyo we-fuel-to-air ukugcina isilinda sombane phantsi kweentloko ezinzima.

Ngokovavanyo olwenziwa yi-United States Consumer Product Safety Commission (CPSC) kunye neNational Institute of Standards and Technology (NIST): - Ijenereyitha enye ye-5,500-watt yepetroli ephathwayo ikhupha ikharbhon monoksayidi eninzi ngeyure njenge-100 ukuya kuma-450 eemoto zabakhweli ezingasebenziyo kule mihla. - Ukukhutshwa kwejenereyitha eluhlaza iqulethe phakathi kwe-**20,000 ppm kunye ne-80,000 ppm (2% ukuya kwi-8%) i-carbon monoxide ecocekileyo **, eyi-16 ukuya kuma-65 amaxesha oxinaniso oluthathwa njengeNgozi kuBomi okanye kwiMpilo (IDLH = 1,200 ppm) yi-United States National Safety Institute and Occupational Health Institute (NI) - Iijeneretha zanamhlanje ezakhelwe kwi-ANSI/PGMA G300 okanye UL 2201 imigangatho yokukhutshwa ephantsi iquka i-onboard CO sensors ezivala ngokuzenzekelayo i-injini ukuba i-CO iqokelela ijikeleze i-generator ngokwayo (ngokuqhelekileyo kwi-400 ppm ngokukhawuleza okanye i-150 ppm ngaphezu kwe-avareji yemizuzu eyi-10). Nangona kunjalo, ** akufuneki uthembele kwi-sensor ye-CO yokuvala ngokuzenzekelayo ukuvumela ukusebenza kwangaphakathi okanye kufutshane nekhaya **, kuba umoya unokuvuthela i-exhaust plume ngqo ngefestile evulekileyo kwigumbi lokulala ngelixa umoya omtsha uhlambulula inzwa efakwe kwisakhelo sejeneretha.

I-Cellular pathophysiology ye-carbon monoxide poisoning

Xa i-carbon monoxide ingena emiphungeni, iwela inwebu ye-alveolar-capillary ngokukhawuleza kwaye ihlasele ukuthuthwa kweoksijini kumanqanaba amathathu ahlukeneyo ebhayoloji:

  1. Ukwenziwa kweCarboxyhemoglobin (COHb): Ikharbhon monoxide ibophelela kwiiathom ze iron kwihemoglobin ngokudibana 200 ukuya kuma 250 amaxesha omelele kuneoksijini. Kwanaxa umoya une-0.1 ekhulwini kuphela ye-CO (1,000 ppm) ecaleni kwe-20.9 ekhulwini yeoksijini, i-carbon monoxide yodlula ioksijini kwaye iguqula isiqingatha se-hemoglobin ejikelezayo yomzimba ibe yi-carboxyhemoglobin engasebenziyo kwimizuzu engama-30 ukuya kuma-45.
  2. I-Haldane Effect (i-shift-left ye-oxygen dissociation): Xa i-CO ibophelela kwenye yeendawo ezine ezibophelela i-oksijini kwimolekyuli ye-hemoglobin, iguqula ubume besakhiwo seprotheni ukuze iimolekyuli ezintathu ze-oksijini eziseleyo zibanjwe ngokuqinileyo kwaye ** azikwazi ukukhutshwa ** kwingqondo elambileyo i-oksijini kunye nezicubu zentliziyo.
  3. **I-intracellular cytochrome c oxidase inhibition kunye ne-lipid peroxidation **: I-carbon monoxide echithiweyo ingena kwiiseli zemisipha yentliziyo (ibophelela kwi-myoglobin ye-cardiac kunye ne-depressing output ye-cardiac) kwaye inhibits ** i-cytochrome c oxidase ** ngaphakathi kwe-mitochondria, ukuvala i-cellular cell ATP ukuveliswa kwe-oxygen ukulibaziseka, ukuvelisa ukuveliswa kwamandla oksijini kunye ne-genering yengqondo emhlophe) iintsuku okanye iiveki emva kokuba sesichengeni.

Ugxininiso lweCarbon monoxide vs itafile yokuqhubela phambili kweklinikhi

Inqanaba le-CO engqongileyo (ppm) Ubude bexesha lokutyhileka ICarboxyhemoglobin (COHb%) Iimpawu zeklinikhi kunye neMpembelelo yePhysiological Inyathelo elifunekayo
9 ppm Iiyure ezisi-8 < 2% Umbutho wezeMpilo weHlabathi (i-WHO) kunye ne-US EPA ubuninzi obukhuselekileyo ngaphandle/kwindawo yokuhlala iiyure ezisi-8 zesikhokelo. Ukubeka iliso okuqhelekileyo.
35 ukuya ku-50 ppm Iiyure ezisi-8 5% ukuya kwi-8% Ubuninzi obuvumelekileyo bomda wokuvezwa emsebenzini (NIOSH 35 ppm / OSHA 50 ppm / UK HSE 20 ppm 8-hr TWA). Intloko ebuhlungu kumaqela abuthathaka. Yandisa umoya kwaye ujonge indlela yokuphuma.
70 ppm Iiyure ezi-1 ukuya kwezi-4 10% ukuya kwi-15% Umgangatho we-UL 2034 wokuhlala we-alarm ye-alarm ibangela umda (kufuneka ivakale ngaphakathi kwe-60 ukuya kwi-240 imizuzu). Intloko efihlakeleyo yangaphambili, ukudinwa, ukuphefumla nzima xa usenza umthambo. Vala ijenereyitha ngokukhawuleza kwaye uhambe ngaphandle.
150 ukuya ku-200 ppm Imizuzu engama-30 ukuya kwengama-90 20% ukuya kwi-25% I-alarm ye-UL 2034 ibangela ngaphakathi kwe-10 ukuya kwi-50 imizuzu. Ukuqaqanjelwa yintloko yetempile, isiyezi, isicaphucaphu, ukubhideka okungephi, ukonakala kwesigwebo. Phuma kwisakhiwo ngokukhawuleza kwaye ubize iinkonzo eziphuthumayo.
400 ppm Imizuzu eyi-15 ukuya kwengama-60 30% ukuya kwi-40% I-alarm ye-UL 2034 ibangela ngaphakathi kwe-4 ukuya kwi-15 imizuzu. Intloko ebuhlungu kakhulu, ukuhlanza, ukungaboni kakuhle, tachycardia, ataxia (ukukhubeka), ukuwa xa umile. Phuma emoyeni omtsha; fowunela 911/112/999 100% unyango oxygen.
800 ppm Imizuzu eli-15 ukuya kwengama-45 45% ukuya kwi-55% Ukuxhuzula, ukulahlekelwa zingqondweni, ukuphefumla kukaCheyne-Stokes, isiqaqa, nokufa kwisithuba semizuzu engama-45 ukuya kwengama-60. Ukuhlangulwa ngokukhawuleza ngabacimi bomlilo kwi-SCBA; Ukuqwalaselwa kweoksijini ye-hyperbaric.
1,200+ ppm (IDLH) 1 ukuya kwi-15 imizuzu > 60% Ngoko nangoko ingozi kuBomi okanye kwiMpilo. Ukulahlekelwa yingqondo emva kokuphefumula kwe-2 ukuya kwe-3; ukubanjwa kwentliziyo kunye nokufa kwengqondo phantsi kwemizuzu eyi-15. Musa ukungena kwindawo evaliweyo ngaphandle kwezixhobo zokuphefumla ezizimeleyo (SCBA).

Ukuba nabani na ekhaya ufumana intloko ebuhlungu, isiyezi, isicaphucaphu, ukubhideka, okanye ukuba i-alarm ye-carbon monoxide iyakhala, jonga kwakhona. ityhefu yecarbon monoxide uncedo lokuqala ngokukhawuleza: ngenisa wonke umntu ngaphandle emoyeni omtsha ngaphandle kokuyeka ukucima ijenereyitha ukuba ikwindawo ebiyelweyo, kwaye ufowunele ingingqi yakho. amanani kaxakeka (Ama-911 eUnited States naseKhanada, ali-112 kulo lonke iManyano yaseYurophu, angama-999 eUnited Kingdom).


I-physics ye-6-meter (i-20-foot) yomgaqo wokukhutshwa kwangaphandle

Ii-arhente zoKhuseleko kwihlabathi jikelele, kubandakanywa iKomishoni yoKhuseleko lweMveliso yoMthengi wase-United States (CPSC), amaZiko oLawulo lweZifo kunye noThintelo (CDC), uMbutho woKhuseleko loMlilo weSizwe (NFPA), kunye neeNkonzo zoMlilo kunye nokuHlangula e-United Kingdom nase-Australia, gunyaza ubuncinci ** imitha ye-6 (i-20-foot) imvume yangaphandle ** phakathi kwejeneretha ephathekayo kunye naluphi na isakhiwo esihlala kuyo, kunye nendawo yokukhupha.

Nasi isizathu sokuba imigama ekufutshane ingaphumeleli nangaphandle: 1. Ulwakhiwo lwezowuni zokujikeleza kokuvuka: Xa umoya uvuthuza phezu kophahla olumisiweyo okanye ujikeleze iindonga zendlu, udala indawo yokuvuka yoxinzelelo oluphantsi oluya kwi-1.5 ukuya kwi-4.5 yeemitha (5 ukuya kwi-15 iinyawo) kude nodonga lomoya. Ijenereyitha ebekwe nje ngeemitha ezi-1.5 (iinyawo ezi-5) ngaphandle kocango olungasemva ihlala ngqo ngaphakathi kweliqamza lokujikeleza kwakhona kwe-aerodynamic; endaweni yokuvuthela, igesi ephumayo ifunxelwa phezulu ngokubhekiselele kwicango elingaphandle, ingene ngefestile, imingxuma yokulila, iiventi ze-attic, kunye neengcango zokutyibilika. 2. Isixhobo sokufunxa umoya esifakwe ngumatshini: Ngelixa ifeni yesithando somlilo sendlu, isitshizi sokukhupha impahla kwigumbi lokuhlambela, esomisi mpahla, okanye i-heat-recovery ventilator (HRV) yendlu yonke isebenza ngamandla ejenereyitha, iyicinezela indlu kancinane, itsala umoya wangaphandle ngaphakathi kuyo yonke imikroskopu ekwimvulophu yesakhiwo. 3. Ingozi yekhaya ebumelwaneni: Kwiindawo ezixineneyo zasezidolophini okanye kwizindlu zasedolophini ezineeyadi ezimxinwa ezisecaleni, ukubeka ijenereyitha ezimitha ezi-6 (iinyawo ezingama-20) ukusuka kwiveranda yakho engasemva ungayibeka kumgama weemitha ezi-2 (iinyawo ezi-6.5) kwifestile yegumbi lokulala elivulekileyo lommelwane wakho. Soloko ujonga umgama ukuya zombini isakhiwo sakho kunye namakhaya akufuphi.


Uqhagamshelo lombane: iiswitshi zotshintshiselwano, ii-interlocks, kunye ne-backfeeding

Indlela owuthumela ngayo umbane osuka kwijenereyitha yakho ukuya kwisixhobo sakho iqinisekisa ukuba useto lwakho lukhuselekile kwaye luyayithobela ikhowudi (phantsi kweNFPA 70 / Ikhowudi yoMbane yeSizwe yeSiqendu 702 eUnited States, CSA C22.1 eKhanada, kunye neBS 7671 IET Wiring Regulations eUnited Kingdom) okanye ingozi ebulalayo yombane.

Kutheni i-backfeeding yombane ibulala abasebenzi kwaye itshabalalisa iijeneretha

Ukubuyisela emva kwenzeka xa umntu eplaga ijenereyitha kwisixhobo esisemgangathweni sodonga lwendlu, indawo yokuphuma igaraji, okanye i240-volt isomisi sempahla yombane/isokethi yoluhlu esebenzisa intambo yeplagi eyindoda eyenziwe yasekhaya okanye engekho mthethweni ephuma kabini (eyaziwa jikelele kurhwebo lombane njenge ntambo yokuzibulala).

Ungaze wakhe, uthenge, okanye usebenzise intambo yendoda ukuya kwindoda ngezizathu ezine: 1. Izintlu eziveziweyo zobhedu: Lo mzuzu uqhoboshela isiphelo sentambo yendoda ukuya kwindoda kwijenereyitha ebalekayo, iiprongs zobhedu ezingakhuselwanga kwelinye icala esandleni sakho zixhotyiswe nge-120 okanye i-240 volts kwi-30 amps, ekwaziyo ukubangela ukufa kwangoko kwi-ventricular fibrillation yentsimbi ukuba i-fibrillation yentsimbi yakho. 2. Reverse transformer step-up to 7,200+ volts: Ukuba uyalibala ukucima eyona ndawo ingundoqo yekhaya lakho i-100-amp okanye i-200-amp yesaphuli sokungena kwenkonzo (okanye ukuba isaphuli-mthetho esingundoqo sinempazamo yangaphakathi edityanisiweyo), umbane osuka kwijenereyitha yakho uqukuqela umva uphuma kwiphaneli yebreaker, unyuse inkonzo yakho engaphezulu kwentloko, yehla kwaye ungene kwindawo ephantsi komhlaba ujiko lwesibini. Iziguquli zizixhobo ze-electromagnetic ezijikelezayo: ukondla 240 volts ukuya kwinqanaba lesibini amanyathelo ombane ukuya kuthi ga kwi-7,200 volts, 13,800 volts, okanye 14,400 volts kwimigca yesitrato ethotyiweyo. Abasebenzi beentambo eziluncedo kwiimayile kude okanye amasebe okucoca eyadini yakho banokubulawa ngumbane. 3. Ukugqitha ukhuseleko lwesekethe yesebe: Ukondla i-high-amperage yangoku ngasemva kwi-15-amp wall receptacle inokulayisha ngaphezulu ngaphakathi kwe-14 AWG Romex wiring ngaphakathi kweendonga zakho ngaphambi kokuba i-breaker ihambe, ukuqala ngokufihlakeleyo. umlilo wombane. 4. Ugqabhuko lwejenereyitha olukhawulezayo xa amandla aluncedo ebuya: Ukuba amandla egridi aluncedo abuyiselwe ngelixa ijenereyitha yakho ibuyisela umva indawo yolawulo ngaphandle kwesigaba kunye nesixhobo sokusetyenziswa kwe sine wave, 10,000+ iiamps zemposiso esebenzayo ngoku slam ngqo kumajiko estator ejenereyitha yakho, ngogonyamelo ukwaphula ijenereyitha, icandelo lomlilo eliqhekezayo, isakhiwo somlilo esiqhekezayo kunye nesixhobo sokutshintsha isitshixo.

Ukuthelekiswa kweendlela ezine zokudibanisa i-generator

Indlela yoQhagamshelwano Indlela Esebenza Ngayo Ukhuseleko kunye nokuThotyelwa kweKhowudi (Ubugcisa be-NEC 702 / BS 7671) Amandla eeSekethe eziHardwired (Isithando somlilo, iMpompa elungile)? Iindleko eziFakelweyo eziqikelelweyo
1. Iintambo zoLwandiso lwaNgaphandle oluNxibele ngokuNgqongileyo Izixhobo zombane ziplaga ngqo kwiivenkile ze-GFCI kwijenereyitha nge-10 AWG okanye i-12 AWG yeentambo zangaphandle ezihanjiswa ngokukhuselekileyo ukuya ekhaya. 100% Ikhuselekile kwaye iyahambelana (Uqhagamshelo olungenaziro kwiingcingo zendlu; umngcipheko we-backfeed awukho). Hayi (Inika amandla kuphela izixhobo zeplug-in: ifriji, isikhenkcisi, impompo yesump ephathekayo, izibane, iitshaja). I-50 ukuya kwi-150 USD (ixabiso le-10/12 AWG iintambo).
**2. Uluhlu oludwelisiweyo lwe-Mechanical Breaker Interlock Kit + Ibhokisi yokungena ** I-CNC-machined steel sliding plate efakwe kwi-main panel ye-breaker cover ikhusela ngokomzimba i-Generator Backfeed Breaker ukuba ivule ngaphandle kokuba i-Main Utility Breaker ivaliwe ngokupheleleyo. 100% Ikhuselekile & Iyahambelana xa usebenzisa ikhithi ye-interlock efakwe kuluhlu lwe-UL / iphaneli-umenzi-eyamkelweyo efakwe ngusombane. Ewe (Ikuvumela ukuba ukhethe ngokukhethayo nayiphi na isekethi kwiqela lakho eliphambili ukuya kumda wamanzi omenzi wejenereyitha). I-350 ukuya kwi-800 USD (iinxalenye + zombane ezinelayisensi).
3. Iphaneli engaphantsi yoTshintsho lweManuwali (MTS) (iiSekethe ezi-6 ukuya kwezili-10) I-subpanel ezinikeleyo ecaleni kwebhokisi yakho ephambili nomntu ngamnye LINE / OFF / GEN iiswitshi ze-6 ukuya kwi-10 iisekethe zekhaya ezibalulekileyo, zondliwa yi-NEMA L14-30P yangaphandle okanye i-CS6365 ibhokisi yokungena. 100% Ekhuselekileyo & Iyahambelana (Ikwahlula ngokupheleleyo iisekethe ezikhethiweyo kwigridi yoncedo; ihlala ibandakanya iiwattmeters ezakhelwe ngaphakathi). Ewe (Amandla okuvuthela ngegesi enziwe ngocingo oluqinileyo/ioyile, impompo yequla enzulu eyi-240V, ifriji yasekhitshini, kunye neesekethe zokukhanyisa). I-600 ukuya kwi-1,400 USD ifakiwe.
4. Ukutshintshela ngokuzenzekelayo (ATS) eneGenereyitha yokulinda Irhasi yendalo esisigxina yangaphandle okanye ijenereyitha yepropane (10 kW ukuya kuma-26 kW) eva ilahleko yegridi, ikhuphe unxibelelwano olungundoqo ngokuzenzekelayo, kwaye iqale kwimizuzwana eli-10. 100% Ikhuselekile & Iyahambelana (Yenzeka ngokupheleleyo; isafuna i-1.5 m / 5 ft ukukhutshwa kwefestile ngokweNFPA 37 kunye noluhlu lomvelisi). Ewe (Indlu yonke inamandla okanye ilawulwa ngumgangatho ophezulu we-HVAC ilayisha ngokuzenzekelayo). I-5,000 ukuya kwi-15,000 + USD ifakiwe.

Ukwandiswa kweentambo zokulinganisa, i-American Wire Gauge (AWG), kunye nokwehla kwamandla ombane

Ukuba uqhagamshela izixhobo zombane ngokuthe ngqo kwijenereyitha yakho ephathwayo usebenzisa iintambo ezongezelelekileyo, ungaze usebenzise iintambo zesibane zasendlini ezisebenza ukukhanya okanye iintambo ezicekethekileyo ze-16-gauge (16 AWG) zezichebi zegadi eziorenji. Iingcingo zobhedu ezibhityileyo zinokuxhathisa umbane. Xa icompressor yesikhenkcezisi okanye i-sump pump motor itsala isantya sokuqala esinzima kwintambo ende, ebhityileyo, izinto ezimbini eziyingozi zenzeka ngaxeshanye: 1. Ukwehla kwamandla ombane kutshabalalisa isixhobo sesixhobo sombane: Ukuba ii-volts ezili-120 ziyishiya ijenereyitha, ukuxhathisa kwintambo yeemitha ezingama-30 (iinyawo ezili-100) ze-16 AWG kunokwehlisa umbane ofikelela kwifriji yakho ukuya kuma-98 volts. Iimotor zokungenisa umbane zizixhobo zamandla angaguqukiyo: xa umbane wehla, imotor itsala i-amperage ephezulu (Amps = Watts / Volts), ukutshisa i-compressor windings kunye nokutshisa ifriji yakho okanye impompo ye-sump. 2. **I-Joule yokufudumeza inyibilikisa ibhatyi yentambo **: Amandla achithwayo njengoko ubushushu kwintambo bulingana namaxesha angoku aphindwe kabini ukumelana ($ P = I^ 2R $). Intambo ejijekileyo okanye engaphantsi kobukhulu obuthwele ii-amps ezili-15 inokudlula i-100 degrees celcius (212 degrees Fahrenheit), inyibilikisa ukugquma kwayo kwePVC kunye neeragi ezivuthayo okanye ingca eyomileyo. Ngalo lonke ixesha khulula iintambo zokwandisa ngokupheleleyo xa iphantsi komthwalo ukuze ubushushu buphele emoyeni.

Ulwandiso lwegeyiji yocingo lwentambo (AWG / metric \(\text{mm}^2\)) ireferensi yokulinganisa itafile

Ubuninzi bomthwalo oqhubekayo (Amps) Ubukhulu bomthwalo kwi-120V (Watts) Ubuncinane boBubungakanani bocingo ukuya kuthi ga kwi-15 m (50 ft) Ubuncinane bobungakanani bocingo kwi-15 m ukuya kwi-30 m (50 ukuya kwi-100 ft) Ibhatyi yangaphandle eCetyisiweyo kunye noHlobo lwePlagi
Ukuya kuthi ga kwii-Amps ezili-10 1,200 Watts 14 AWG (\(2.08\text{ mm}^2\)) 12 AWG (\(3.31\umbhalo{ mm}^2\)) Ngaphandle SJTW okanye SOOW (i-3-prong isekelwe kwi-NEMA 5-15P)
10 ukuya kwi-15 Amps 1,800 Watts 12 AWG (\(3.31\umbhalo{ mm}^2\)) 10 AWG (\(5.26\umbhalo{ mm}^2\)) Umsebenzi onzima 12/3 SJTW okanye irabha SOOW
15 ukuya ku-20 Amps 2,400 Watts 10 AWG (\(5.26\umbhalo{ mm}^2\)) 10 AWG (\(5.26\umbhalo{ mm}^2\)) Umsebenzi onzima 10/3 SOOW (NEMA 5-20P okanye L5-20P twist-lock)
30 iiAmps (120/240V Ukwahlulwa-Isigaba) 7,200 Watts 10 AWG (\(5.26\text{ mm}^2\), 4-wire) 8 AWG (\(8.36\text{ mm}^2\), 4-wire) 4-I-Conductor 10/4 okanye 8/4 SOOW nge NEMA L14-30P twist-lock
50 iiAmps (120/240V Ukwahlulwa-Isigaba) 12,000 Watts 6 AWG (\(13.3\text{ mm}^2\), 4-wire) 6 AWG (\(13.3\text{ mm}^2\), 4-wire) 4-I-Conductor 6/3+8/1 SOOW nge NEMA 14-50P / CS6364 iplagi yokutshixa

Qaphela kwiintambo zomzila ngaphakathi endlini: Xa usebenzisa intambo yolwandiso olusuka kwijenereyitha yangaphandle ngefestile okanye ucango olungena endlwini, ungaze uyishiye ifestile ivuleke ivuleke apho umsi wokukhupha umsi unokukhukuliseka ngaphakathi. Endaweni yoko, gqithisa intambo, vala i-sash yefestile phantsi ngobunono kumtya oshinyeneyo wombhobho-insulation foam okanye itawuli esongiweyo (uthathele ingqalelo ukuba ungaculi okanye utyumze isigqubuthelo sentambo), kwaye uteyiphe isithuba sivalwe ngomzobi okanye iteyiphu yokuqhagamshela.


I-Grounding, i-nege-to-frame bonding, kwaye kutheni i-GFCI breakers ihambe

Enye yezona zinto zingxamisekileyo zobuchwepheshe ezididayo ngexesha lokumka kombane kwenzeka xa umninimzi eplaga ijenereyitha yakhe entsha kraca kwiswitshi yokudlulisa ikhaya okanye ibhokisi yokungena, iqala injini, kunye nebhodi yejeneretha GFCI (I-Ground Fault Circuit Interrupter) i-breaker main trips ngoko nangoko, iwacima onke amandla.

Ukuqonda umahluko phakathi kwe- Bonded Neutral generator kunye Floating Neutral generator isombulula le ngxaki ngokukhuselekileyo:

  1. Kutheni i-OSHA jobsite generators have a Bonded Neutral: Uninzi lweejenereyitha eziphathekayo ezivulekileyo ezivulekileyo ezithengiswa kwiivenkile zehardware ziza ne umqhubi ongathathi hlangothi odityaniswe ngokuthe ngqo kwisakhelo sentsimbi yejenereyitha (Neutral-to-Ground Bonded). Ngaphantsi kwemigangatho yokwakha ye-OSHA yase-United States (29 CFR 1926.404), xa i-generator isetyenziswa ngokuzimeleyo kwisiza sokwakha kunye neentambo zokwandisa, ibhondi yangaphakathi ye-generator isebenza njengereferensi yenkqubo ukuze i-GFCI ikhuphe i-GFCI ikwazi ukubona iimpazamo zomhlaba ngaphandle kokufuna ukubethelela i-2.4-meter (8-foot) intonga yomhlaba wobhedu.
  2. Kwenzeka ntoni xa uplaga i-Bonded Neutral generator kwi panel yendlu: Kwiingcingo zokuhlala ezisemgangathweni (North American NEC kunye ne-UK PME/TN-C-S systems), iphaneli yenkonzo ephambili yekhaya lakho sele ibhondi iNeutral ukuya kuMgangatho kwindawo enye kwaye iqhagamshelwe kwiintonga zomhlaba eziqhutywa likhaya lakho. Ngaphantsi kweCandelo le-NEC ye-250.24, inkqubo yombane ivunyelwe kuphela ** enye ** ibhondi engathathi hlangothi ukuya emhlabeni.
  3. Ukuba uqhagamshela i Bonded Neutral generator ukuya kwi-standard yebreaker interlock okanye i-2-pole transfer switch (etshintsha imilenze emibini eshushu. L1 kwaye L2 kodwa ushiya ucingo olungathathi hlangothi luqhagamshelwe ngokuqinileyo kwibhasi engathathi hlangothi yekhaya), udala ** iibhondi ezimbini ezinxuseneyo ezingathathi hlangothi ukuya emhlabeni **.
  4. Buyisela ngokungathathi hlangothi kwangoku ukwahlula kwisiqingatha: i-50 ipesenti ibuyela kwintambo emhlophe engathathi hlangothi, kwaye i-50 yepesenti ibuyela kwisixhobo esiluhlaza sokumisa ucingo.
  5. Isivamvo se-GFCI sejeneretha sibona ukuba ukuhamba kwangoku kucingo olushushu akulingani nokubuyisela ngoku kwingcingo engathathi hlangothi, ithatha ukuba kukho umntu oyothukayo, kwaye ngoko nangoko ikhubekise isaphuli sejenereyitha.
  6. Isisombululo esikhuselekileyo:
  7. Usetyenziso lwentambo yolwandiso oluzimeleyo: Gcina umenzi-jenereyitha Ibotshelelwe ngokuNgaphakathi kwiSakhelo, kwaye uplage izixhobo zombane ngqo kwiivenkile ze-GFCI zomenzi.
  8. ** Ukuxhuma kwi-interlock yekhaya eqhelekileyo okanye i-2-pole transfer transfer : I-NEC yeSiqendu 702 ichaza i-generator edibeneyo nge-switch ye-2-pole (apho i-neutral ingatshintshwa) njenge--inkqubo engahlukaniyo ephumayo **. Ijenereyitha kufuneka iqwalaselwe nge-Floating Neutral (okanye kufuneka ufakele iswitshi yokudlulisa eneepali ezi-3). Abavelisi bejenereyitha abaninzi babonelela ngemiyalelo ebhaliweyo kwincwadana yomnini malunga nendlela yokususa ijumpi yokudibanisa ubhedu ngaphakathi kwe-alternator end-cap xa uguqulela iyunithi ngokukodwa ukusetyenziswa kotshintshiselwano lwekhaya, kwaye ifuna ukuncamathelisa ileyibhile esisigxina echaza: *"Isilumkiso: UkuNgaphakathi kokudadayo , UKuqhagamsheleka kwiNdawo kwiNdawo yokuNxibelela kwiNgxowa-mali phambi koNxibelelaniso lweLayisenisi yoMbane Kuphela.

Ukubalwa komthwalo wamanzi, ukuqala kokutyalwa, kunye neejenereyitha ze-inverter

Zonke iimoto zombane (iifriji, izikhenkcezisi zesifuba, iimpompo ze-sump ezisezantsi, iimpompo ezinzulu, ii-furnace blowers, kunye ne-air conditioners zefestile) zitsala **2.5 ukuya ku-4 amaxesha ayo aqhelekileyo okuqhuba i-wattage ** kwi-0.5 yokuqala ukuya kwi-2 imizuzwana ngelixa i-rotor yoyisa inertia yomatshini (Eyaziwa ngokuba yi-Surge Amps * Itshixiwe * I-Start Rocked).

Ukuba utshintshela kwisikhenkcisi sakho, impompo ye-sump, kunye ne-microwave ngesekondi enye kanye, isantya sokuqala esidityanisiweyo siya kudlula umlinganiselo wokunyuka kwe-generator yakho, ukukhubekisa isaphuli somthwalo okanye kubangele i-voltage emdaka emdaka eyonakalisa iibhodi zesekethe ze-elektroniki.

Umbane oyimfuneko wesixhobo sasekhaya kunye netafile yokuqalisa isantya

IsiXhobo saseKhaya esiyimfuneko IiWatts eziqhubayo eziqhubekayo IiWatts zoKuqala ezongezelelweyo Iyonke iPeak Watts efunekayo ekuQaleni UkuQalwa okuPhambili kokuNcitshiswa
Irhasi okanye iOyile yokuVuthela iFani yeSiko (⅓ ukuya kwi-½ HP) 600 ukuya 800 W + 1,200 ukuya kwi-1,600 W 1,800 ukuya ku-2,400 W Okuphambili 1 (Ithintela imibhobho engumkhenkce ebusika)
Impompo yeMpompa eNgaphantsi kweNgxaki (½ HP ukuya kwi-¾ HP, 240V) I-1,000 ukuya kwi-1,500 W + 2,000 ukuya kwi-3,000 W 3,000 ukuya ku-4,500 W Okuphambili 1 (Baleka ngokuthe gqolo ukucinezela itanki yesinyi)
Impompo yeSump yeBasement (⅓ HP ukuya kwi-½ HP) 800 ukuya kwi-1,050 W + 1,300 ukuya kwi-2,150 W 2,100 ukuya ku-3,200 W Eyona nto iphambili 1 (Inqanda izandyondyo zendlu ephantsi ngexesha lezaqhwithi)
Ifriji yale mihla-yeNkwenkwezi yaMandla / Isikhenkcezisi 150 ukuya 400 W + 600 ukuya kwi-1,200 W 750 ukuya ku-1,600 W Okuphambili 2 (Faka emva kwe-sump/i-furnace izinzile)
Isikhenkcisi seChest esizimeleyo 150 ukuya 350 W + 600 ukuya kwi-1,100 W 750 ukuya ku-1,450 W Eziphambili 2
Umatshini we-CPAP (onomfudumezi oshushu) okanye isiXhobo se-Oxygen 60 ukuya 450 W 0 ukuya +200 W 60 ukuya ku-650 W Okuphambili 1 (uKhuseleko kuBomi): Ifuna i-sine wave ecocekileyo (< 5% THD)
I-Window Air Conditioner (5,000 ukuya kwi-10,000 BTU) 500 ukuya kwi-1,200 W + 1,000 ukuya kwi-2,200 W 1,500 ukuya ku-3,400 W Okubalulekileyo 3 (Cima phambi kokuba usebenzise i-microwave okanye impompo yequla)
I-Oven yeMicrowave (1,000W amandla okupheka) okanye Iketile yoMbane 1,200 ukuya kwi-1,500 W 0 W (Ukuxhathisa) 1,200 ukuya ku-1,500 W Okuphambili 4 (Sebenzisa kuphela ngokufutshane kunye neminye imithwalo enzima esusiweyo)
Izibane zeNdlu ye-LED (iibhalbhu ezili-10) + iWi-Fi Router + iLaptop 150 ukuya 250 W 0 W 150 ukuya ku-250 W Eziphambili 2

Imithwalo yombane eyothusayo (iNdlela yokuLayishwa kweNyathelo)

  1. Qalisa kwaye ufudumeze ijenereyitha nge-ZERO imithwalo eqhagamshelwe: Soloko ujijela i-AC yebreaker ye-AC yejenereyitha ukuze OFF (okanye ukhulule zonke iintambo zokwandisa) phambi kokuba utsale umqalisi wokubuyisela. Vumela injini ifudumale kwaye izinze i-RPM yayo (i-3,600 RPM ye-60 Hz amandla aseMntla Melika; i-3,000 RPM ye-50 Hz yaseYurophu / yase-UK / yase-Australia) kwi-*2 ukuya kwi-3 imizuzu ** ngaphambi kokufaka nawuphi na umthwalo wombane.
  2. Qhagamshela oyena mthwalo mkhulu wenjini kuqala: Vula isixhobo sakho esikhulu sokuhlinza kuqala (esifana nempompo yequla enzulu, impompo yesump, okanye isivuthela somlilo), linda imizuzwana eli-15 ukuze injini yayo ifikelele kwisantya sokubaleka, emva koko uqhagamshele kwisikhenkcisi sakho, isikhenkcisi, kunye nezixhobo zombane ezincinci zibe nye ngexesha.
  3. Khulula zonke imithwalo phambi kokuba uvale injini: Ungaze uvumele ijenereyitha yome ngokupheleleyo ngamafutha ngelixa izixhobo zombane zisaplagiwe kwaye zisebenza. Njengoko ijenereyitha ikhupha igesi kwigesi, i-injini ye-RPM iyehla, ibangela ukuba i-frequency yehle ukusuka kwi-60 Hz ukuya kwi-30 Hz kunye ne-voltage eguquguqukayo, nto leyo etshabalalisa iibhodi zokulawula iziko kunye neecompressor zesikhenkcisi. Soloko ukhuphe iplagi yonke imithwalo (okanye flip ibreaker generator OFF), vumela i-injini engalayishwanga iphole kwindawo engasebenziyo imizuzu emi-2, kwaye emva koko ucime ukucima umlilo.

Iyonke i-Harmonic Distortion (THD): i-inverter vs iijeneretha ze-open-frame

  • **Iijeneretha eziqhelekileyo ezivulekileyo ze-open-frame ** zivelisa i-voltage ye-AC eluhlaza ngokuthe ngqo kwisantya se-injini kwaye ngokuqhelekileyo ivelisa ** i-12% ukuya kwi-25% i-Total Distortion Harmonic (THD) **. Ngelixa iinjini ezindala zoomatshini zinyamezela iTHD ephezulu, iziko legesi eliguquguqukayo elinesantya esiphezulu, iifriji ze-Samsung/LG inverter, oomatshini bonyango be-CPAP, kunye nonikezelo lwamandla olungaphazamisekiyo (UPS) bahlala bewagatya amandla nge> 10% THD okanye babandezeleke kwiibhodi zokulawula ezitshileyo.
  • ** Iijeneretha ze-Inverter ** zilungise i-AC eluhlaza kwi-DC kwaye isebenzise i-electronics microprocessor ukuze idibanise ** I-Wave ye-Sine ecocekileyo engaphantsi kwe-3% THD ** (icocekile kumandla ombane oqhelekileyo wegridi), ngelixa itshisa i-30% ukuya kwi-50% yepetroli engaphantsi kwemithwalo kunye nokusebenza kwi-52 ukuya kwi-62 decibels endaweni ye-85 decibels.

I-refueling ekhuselekileyo, ukuzinzisa amafutha, kunye nokugcinwa kwepropane yamafutha amabini

Ipetroli lulwelo oluguquguqukayo olukhethekileyo olunokukhanya kwe-*-43 degrees celcius (-45 degrees Fahrenheit)**, okuthetha ukuba isoloko ikhupha umphunga otshayo nakwizikhephe ezikhenkcezayo zasebusika. Umphunga wepetroli unzima amaxesha ama-3 ukuya kuma-4 kunomoya; xa ichithiwe, umsi ongabonakaliyo uyatshona emhlabeni kwaye uqukuqele ukuhla ngakwindlela zekhonkrithi ukuya kwizibane zokulinga izifudumezi-manzi okanye izilumkiso zejenereyitha ezishushu.

Umgaqo osisinyanzelo we-15-to-20-minute-refueling rule

Ngelixa usebenza phantsi komthwalo, umbhobho wejenereyitha ophathwayo kunye nesigqubuthelo sobushushu sifikelela kumaqondo obushushu aphakathi kwama-450 nama-600 ngokukaCelsius (842 ukuya kwi-1,112 degrees Fahrenheit)**, ngaphezu kwama-280 degrees Celsius (536 degrees Fahrenheit) iqondo lobushushu lokuzivulela lwepetroli. Ukuba i-splash enye yepetroli yolwelo okanye i-plume enzima yomphunga idibana ne-muffler eshushu ngexesha lokufakwa kwe-refueling, iyavutha ngokukhawuleza ngaphandle kokufuna intlantsi, igubungela i-fuel can ezandleni zomqhubi.

  1. Khupha yonke imithwalo yombane kwaye uvale injini yejenereyitha ngokupheleleyo.
  2. Seta isibali-xesha kwaye ulinde 15 ukuya kwimizuzu engama-20 ukuze isigqubuthelo sentloko kunye nesilinda siphole.
  3. Ipetroli usebenzisa kuphela eqinisekisiweyo **UL / ASTM F852 / ilangatye-arrestor ixhotyiswe inkonkxa ebomvu yegesi yokhuseleko ** kunye nefaneli yomlomo obanzi ukuthintela ukutshiza.
  4. Shiya 2.5 ukuya kwi-5 yeesentimitha (i-intshi ezi-1 ukuya kwezi-2) zesithuba somoya kumphezulu wetanki yamafutha ukuvumela i-petroli ebandayo ukuba yande njengoko ifudumala ngaphandle kokuphuphuma kwisivalo segesi ephuma umoya.

Ukugcinwa kwamafutha ixesha elide kunye nokukhuselwa kwe-carburetor

Ipetroli yempompo yanamhlanje edityaniswe ne-10% ye-ethanol (E10) ifunxa ukufuma emoyeni (ukuhlukana kwesigaba) kwaye i-oxidizes kwi-varnish encangathi phakathi kwe-*30 ukuya kwiintsuku ze-60 **, ukuvala iijethi zobhedu ezincinci ngaphakathi kwi-carburetor yejeneretha kunye nokuqinisekisa ukuba i-generator iyakwala ukuqala xa kuvela imeko kaxakeka.

  • **Sebenzisa i-ethanol-free petroli (Rec-90) okanye wongeze i-fuel stabilizer ngokukhawuleza **: Yongeza i-dose elinganisiweyo ye-fuel stabilizer (efana ne-STA-BIL) kwi-gas can kwisikhululo segesi ngaphambi kokuyizalisa, eyandisa ubomi beshelufu ye-petroli kwiinyanga ezili-12 ukuya kwii-24.
  • Gcina ipetroli ngaphandle kwendawo yokuhlala: Ungaze ugcine iinkonkxa zepetroli ngaphakathi kwindlu okanye kwigumbi elingaphantsi. Gcina ukuya kutsho kwiilitha ezingama-75 ukuya kwezingama-95 (iilitha ezingama-20 ukuya kwezingama-25, ujonge imida yekhowudi yomlilo yasekuhlaleni) kwindawo etshixwayo, nephuma umoya yangaphandle kude nelanga elithe ngqo, kwaye ujikelezise amafutha kwitanki yegesi yemoto yakho rhoqo emva kweenyanga ezi-6.
  • Khupha isitya esidadayo sekhabhuretha emva kokucinywa ngakunye: Xa amandla egridi ebuya kwaye ubeka ijenereyitha kude, jika ivalve yepetcock iye OFF ngelixa i-injini isasebenza kwaye uvumele injini iqhube de isitya sokudada se-carburetor some ngokupheleleyo, okanye uvule isikrufu sobhedu esisezantsi kwesitya se-carburetor ukukhupha amafutha aseleyo.
  • Uncedo lweejenereyitha zentsimbi eziMabini (iPropane / LPG): Ngokungafaniyo nepetroli, ipropane yolwelo egcinwe kumgangatho we-9-kilogram (20-ponti) okanye 45-kilogram (100-ponti) iisilinda zentsimbi **ayiphelelwa kudala, ayikhe igawule icarburetor, kwaye inexesha elingenammiselo kwishelufu yobomi obungenammiselo xa igcinwe ngaphandle kweshumi leminyaka eyomileyo.

Ungaze ugcine iitanki zepropane ngaphakathi okanye kumagumbi angaphantsi

Ngalo lonke ixesha gcina iisilinda ze-LPG zepropane ngqo ngaphandle kwindawo enomthunzi, nengena umoya. Ngokungafaniyo negesi yendalo (elula kunomoya kwaye iphakama), igesi yepropane inamaxesha angama-1.5 anzima kunomoya. Ukuba ivalufa yokukhulula itanki yepropane iyavuza ngaphakathi kumgangatho ongaphantsi okanye igaraji encanyathiselweyo, irhasi enevumba elimnandi iqukuqela ngokungabonakaliyo emgangathweni de ifike kwiziko, iswitshi yempompo ye-sump, okanye i-motor yesixhobo kwaye ibangele ugqabhuko-dubulo oluyintlekele.


Isebenza ngokukhuselekileyo emvuleni, kwiikhephu, nakwimozulu emanzi

Ngenxa yokuba umnyama wenkanyamba nomkhenkce ebusika phantse usoloko uzisa izandyondyo zemvula, iliqhwa, okanye ikhephu elivuthuzayo, abaninimzi badla ngokuhendelwa ukuba batsale ijenereyitha ngaphakathi kwigaraji okanye kwiveranda ukuze kungangeni mvula. Ungaze ungenise ijenereyitha phantsi kophahla okanye kwindawo ebiyelweyo ukuze uyikhusele emvuleni.

Endaweni yoko, khusela ijenereyitha yangaphandle kwimozulu emanzi usebenzisa le mithetho mine yobunjineli:

  1. Phakamisa isakhelo ngeesentimitha ezili-10 (i-intshi ezi-4) ngaphezu kweedwana kunye nethambeka: Beka ijenereyitha kumphakamo wepatio pavers, ipali yeplastiki enzima, okanye ipalethi yomthi ebanzi ukuze amanzi emvula kunye nekhephu elinyibilikayo lingadibani emazantsi ealternator okanye isakhelo sevili.
  2. Sebenzisa ikhenopi eqinisekisiweyo evuleke emacaleni ebalekayo (engaze ibe yitarp egqunyiweyo): Ungaze ugqume iseta yeplastiki ngqo phezu kwejenereyitha ebalekayo; iya kunyibilika kwi-500-degree-Celsius muffler ngaphakathi kwemizuzwana engama-60 kwaye ibambe umlilo. Endaweni yoko, faka i-UL-ihlolwe yonke imozulu ye-generator canopy (efana ne-GenTent clamp-on canopy) okanye ubeke iyunithi phantsi kwesakhelo sophahla esincinci esivulekileyo esivulekileyo esihlala kwiimitha ezi-6 (iinyawo ezingama-20) ukusuka kwindlu egcina imvula ngaphandle kweendawo eziphezulu ngelixa ishiya onke macala amane i-100% evulekileyo kwi-airflow.
  3. **Gcina iintaba zekhephu zicocekile zijikeleze umbhobho kunye nomoya othathayo **: Ngexesha leqhwithi ezinzima okanye izaqhwithi zasebusika, jonga ijenereyitha rhoqo kwiiyure ezi-2 ukuya kwezi-3 ukuhlambulula ikhephu elikhukulisayo ukuze ikhephu lingavimbi umoya wokupholisa okanye ukungcwaba umbhobho wokuphuma.
  4. Sebenzisa ukhuseleko lwe-GFCI kunye nezandla ezomileyo: Soloko unxiba izihlangu ezomileyo ezinerabha kwaye uqinisekise ukuba izandla zakho zomile phambi kokuba ubambe iiswitshi zejenereyitha okanye iiplagi ngaphandle. Gcina uqhagamshelo lweplagi yentambo yolwandiso lwangaphandle luphakanyiswe kwingca emanzi (umzekelo, ngaphakathi kwidome yentambo yokutshixa ethintela imozulu okanye uphumle kwibhakethi yeplastiki eguqulweyo).

Yenza uvavanyo lolondolozo lwenyanga lwemizuzu engama-20

Ijenereyitha ehleli eshedini iminyaka emibini ayifane iqale ebumnyameni xa kukho isaqhwithi. Kanye emva kweentsuku ezingama-30 ukuya kwezingama-60, hambisa ijenereyitha yakho ephathwayo ngaphandle (iimitha ezi-6 / 20 ubude), jonga inqanaba le-oyile ye-injini kwidipstick (uninzi lweejenereyitha zale mihla zinenzwa yoxinzelelo lwe-oyile ephantsi ethintela i-injini ukuba iqalise ukuba i-oyile isezantsi kancinci), qalisa injini, kwaye uplage kwi-1,500-watts i-watt heater ukugcina i-heater ye-1,500-watt ukugcina isithuba se-injini yokushisa yangaphakathi okanye imizuzu emi-5. amatywina, kwaye akhuphe ukufuma kwi-alternator windings.


Imibuzo ebuzwa qho

Can I run a portable generator inside my garage if I leave the big garage door wide open and point the exhaust outside?

No, never run a generator inside an attached or detached garage, even with the garage bay door completely open and a box fan blowing outward. Wind currents flowing over your roof create low-pressure suction pockets inside open garages that pull exhaust gas backward and force carbon monoxide through door seals, ceiling drywall seams, and ductwork directly into your living room and upstairs bedrooms, reaching fatal levels in less than 15 to 30 minutes.

How far away from my house and windows must a portable generator be placed?

Place a portable generator outdoors at least 6 meters (20 feet) away from your house and at least 6 meters (20 feet) away from your neighbors' houses, with the engine exhaust pipe pointed downwind and away from all windows, doors, soffit vents, and furnace fresh-air intakes. Permanent natural-gas standby generators enclosed in factory-listed weatherproof cabinets must follow NFPA 37 and manufacturer clearance rules, typically at least 1.5 meters (5 feet) from any window or wall opening.

Why is plugging a generator into a dryer outlet or wall socket with a double-male cord so dangerous?

Using a double-male "suicide cord" to backfeed a wall or dryer outlet is illegal and lethal for three reasons: first, the exposed brass prongs on the unplugged end carry live 240-volt current that can kill you instantly if touched; second, if your main utility breaker is not isolated, power flows backward through your street's utility pole transformer, stepping 240 volts up to 7,200 to 14,400 volts and electrocuting utility line workers; and third, if grid power returns while your generator is connected, utility fault current will violently destroy your generator and ignite an electrical fire. Always use a licensed transfer switch or mechanical breaker interlock.

Why does my generator's GFCI breaker trip immediately when I plug it into my house transfer switch?

Most portable generators come with the neutral wire bonded to the generator frame (Bonded Neutral) to meet OSHA rules for standalone extension cord use. Because your home's main electrical panel already bonds neutral to ground, connecting a bonded-neutral generator to a standard 2-pole transfer switch or breaker interlock creates two parallel neutral-to-ground bonds. Return current splits between the neutral and ground wires, causing the generator's GFCI sensor to detect an imbalance and trip immediately. Have a licensed electrician verify whether your generator should be configured to a Floating Neutral for home panel use or install a 3-pole switched-neutral transfer switch.

How do I protect my portable generator when it is pouring rain or snowing during a blackout?

Never move the generator under a porch, carport, or garage to keep it dry. Instead, keep it 6 meters (20 feet) outdoors, elevate it 10 centimeters (4 inches) off wet ground on concrete pavers or a sturdy platform so puddles cannot reach the frame, and install a certified, clamp-on open-sided generator running canopy (such as a GenTent) that shields the top electrical panel and fuel cap from rain while leaving all four sides completely open for cooling airflow and exhaust dissipation.

How often do I need to change the oil in a portable generator running continuously during a multi-day outage?

Most small air-cooled generator engines do not have pressurized automotive oil filters and hold less than 1 liter (1 quart) of oil. Check the oil dipstick every time you shut down to refuel (every 8 to 10 hours). For a brand-new generator, perform the first break-in oil change after the first 20 to 25 hours of runtime to flush out metallic break-in shavings, and change the oil every 50 to 100 hours of continuous operation thereafter using SAE 10W-30 or full-synthetic 5W-30 (in freezing winter temperatures). Always keep 3 to 4 spare bottles of motor oil in your emergency kit.


Imithombo ijongiwe

  • IKomishoni yoKhuseleko lweMveliso yoMthengi eUnited States (CPSC) (eUnited States): Isilumkiso soKhuseleko lweGenereyitha kunye neCO Emission kunye ne-ANSI/PGMA G300 / UL 2201 yeeNgxelo zobuChwephesha (i-6-imitha / 20-foot-foot outdoor yokubekwa kwangaphandle, iimvavanyo ze-aerodynamic emnyango wegaraji, kunye namazinga okukhutshwa kwe-CO eninzi).
  • ** Umbutho woKhuseleko loMlilo weSizwe (i-NFPA) (eUnited States)**: * I-NFPA 70: IKhowudi yeSizwe yoMbane (NEC) iSiqendu 702 (IiNkqubo eziKhethekileyo zokulinda) * kunye * neSiqendu 250 (i-Grounding and Bonding) *, kunye * ne-NFPA 37: uMgangatho woFakelo kunye nokuSetyenziswa kweeNjini zokuThengisa ezimileyo *.
  • Amaziko oLawulo lweSifo kunye noThintelo (CDC) kunye neZiko leSizwe loKhuseleko lwezeMisebenzi kunye neMpilo (i-NIOSH) (eUnited States): *Ityhefu yeCarbon monoxide emva kweNtlekele * kunye * Isikhokelo sePokotho yeNIOSH kwiiNgozi zeMichiza (iCarbon Monoxide IDLH = 1,200 ppm) *.
  • UKhuseleko loMsebenzi kunye noLawulo lwezeMpilo (i-OSHA) (eUnited States): IPhepha leNgcaciso yoKhuseleko lweGenereyitha kunye ne-29 CFR 1926.404 (i-Grounding and GFCI Protection).
  • I-Health and Safety Executive (HSE) kunye noKhuseleko loMbane kuQala (eUnited Kingdom): uKhuseleko lweGeneretha kunye ne-BS 7671 IET Wiring Regulations for Standby Supplies.
  • I-Canadian Standards Association (CSA) kunye noRhulumente waseKhanada (eCanada): *CSA C22.1 IKhowudi yoMbane yaseKhanada * kwaye Zilungiselele: Ukusetyenziswa ngokukhuselekileyo kweeGenereyitha eziphathwayo.

Izikhokelo ezinxulumeneyo