Skip to content

Ukuphela kukagesi ekhaya: ukuphepha kukagesi, ukuqhubeka kwezokwelapha, nokugcinwa kokudla

Izinombolo zezimo eziphuthumayo ziyehluka ngezwe. Leli khasi lisebenzisa u-911, inombolo yase-United States naseCanada. Amanye amazwe amaningi asebenzisa u-112, 999, noma enye inombolo. Thola inombolo yezwe lakini.

Ukucinywa kwegridi kagesi okusabalele kukhubaza ukushisisa nokupholisa kwendawo yokuhlala, kumisa isiqandisi, kuvala amaphampu angasese aphuma emanzini, futhi kuphazamise imishini yezokwelapha yasekhaya esebenza ngogesi. Nakuba ukucisha okuningi kokusabalalisa kwendawo kuxazululeka emahoreni ambalwa, izivunguvungu zeqhwa zasebusika ezinamandla, amagagasi okushisa, imililo yequbula, ukuphazamiseka kwe-geomagnetic, kanye nokwehluleka kwemishini yesiteshi esincane kungashiya izindawo ezingomakhelwane zingenawo amandla izinsuku noma amaviki. Ngokudabukisayo, ukubhekwa kwezempilo yomphakathi kubonisa ukuthi ukufa ngemva kokucisha umlilo kuvame ukudlula inani lesiphepho sokuqala ngenxa yezingozi zesibili ezingavinjelwa: ubuthi be-carbon monoxide endlini obuphuma kumajeneretha aphathekayo namalahle amalahle, umlilo wezindlu oqalwe ngamakhandlela angagadiwe, kanye nokugula okunzima okubangelwa ukudla noma okubangelwa amanzi.

Lo mhlahlandlela uhlinzeka ngezinqubo zokusebenza zesinyathelo nesinyathelo ezihambisana neziqondiso zokuphepha ezivela ku-Federal Emergency Management Agency (FEMA, United States), uMnyango Wezolimo wase-United States (i-USDA) kanye Nokuphathwa Kwezokudla Nezidakamizwa (i-FDA), i-Centers for Disease Control and Prevention (CDC, United States), i-Health and Safety Executive (HSE, United Kingdom), kanye ne-National Fire Protection Association (NFPA). Ukuhlukanisa amasekhethi adonsa kakhulu, ukuphoqelela imithetho eqinile yokudla kwamaketanga abandayo, ukusebenzisa amajeneretha aphathekayo okungenani amamitha angu-6 (amafidi angu-20) ngaphandle, nokugcina amazoni amancane ashisayo kuzogcina ikhaya lakho liphephile kuze kubuye amandla egridi.

Yenza lokhu manje

Uma igridi kagesi ihluleka futhi ikhaya lakho liba mnyama:

  1. Hlola ukuthi ukuphela kwendlu yakho kuphela noma umgwaqo wonke, bese ukubike: Bheka ngefasitela ukuze ubone ukuthi izibani zasemgwaqweni nemizi engomakhelwane kumnyama yini. Uma omakhelwane bakho besenamandla, hlola iphaneli yakho yokuhlala eyinhloko yokuphula ugesi ukuze uthole i-breaker enkulu ehlatshiwe. Uma indawo imnyama, bika ngokucisha ngokushesha usebenzisa uhlelo lokusebenza lwe-smartphone yensiza kagesi, ulayini wombhalo we-SMS ozenzakalelayo, noma inombolo yocingo ecishayo. Ungalokothi ushayele abezimo eziphuthumayo ukuze nje ubuze ukuthi amandla azobuya nini; shayela inombolo yakho yasendaweni yezimo eziphuthumayo (911 e-United States naseCanada, 112 ngaphesheya kwe-European Union, 999 e-United Kingdom) ngokusebenzisa yethu izinombolo eziphuthumayo uhla lwemibhalo KUPHELA uma kunesimo esiphuthumayo sezokwelapha esisongela ukuphila, umlilo wesakhiwo osebenzayo, intambo yamandla ezinhlansi ezehlisiwe, noma okusolwa ukuthi kunobuthi be-carbon monoxide.
  2. Shintsha amadivaysi ezokwelapha asekela ukuphila enze ikhophi yasenqolobaneni yebhethri ngokushesha: Uma noma ubani ekhaya ethembele kumshini wokungenisa umoya, isigxivizo somoya-mpilo, idivayisi yokusiza i-ventricular (LVAD), noma umshini we-dialysis wasekhaya, qinisekisa ukuthi ibhethri langaphakathi noma i-Uninterruptible Power Supply (UPS) ibandakanyekile, shintsha iziguli ezithembele kumoya-mpilo ziyise kusilinda sazo esilondoloza igesi ecindezelwe eluhlaza (E-tank or H-tank), futhi uqaphe amahora ebhethri asele eduze.
  3. Khipha izinto zikagesi ezizwelayo futhi uvale izinqamuli zezinto zikagesi ezisindayo: Khipha amakhompyutha, amathelevishini, amarutha, nezinto zikagesi ze-countertop ezindaweni eziphuma ebondeni, bese upheqa ama-circuit breaker VALIWE ku-air conditioner yakho emaphakathi, iphampu yokushisa, isithando somlilo sikagesi, nesifudumezili samanzi sikagesi. Lapho izisebenzi zinika amandla kabusha igridi, amandla kagesi avame ukukhuphuka ngamandla futhi i-compressor kanyekanye iqale kabusha ezinkulungwaneni zamakhaya ("inrush current") ingashisa izinjini zikagesi noma iphinde ishaye ama-transformer aseduze.
  4. Shiya iswishi yokukhanya yangaphakathi "yesilinda" eyodwa sivuliwe: Gcina isibani segumbi le-LED esingashisi kakhulu noma isibani sevulandi sishintshelwe endaweni ethi VULIWE ukuze ube nesignali ebonakalayo lapho amandla okusebenza ebuyiselwa khona.
  5. Gcina iminyango yesiqandisi neyesiqandisi ivalwe ngokuqinile: Yala wonke umuntu osendlini ukuthi angasivuli isiqandisi noma iminyango yesiqandisi ngaphandle uma kunesidingo. Isiqandisi esingavuliwe sigcina ukudla kubanda ngokuphephile (ku-4 noma ngaphansi kuka-4 degrees Celsius / 40 degrees Fahrenheit) amahora angu-4*, isiqandisi esigcwele uhhafu sibamba amazinga okushisa aphephile amahora angu-24, futhi isiqandisi esifakwe ngokuqinile esigcwele sibamba amazinga okushisa aphephile amahora angu-48.
  6. Sebenzisa amathoshi ebhethri e-LED noma amalambu futhi ugcine amajeneretha okungenani amamitha angu-6 (amafidi angu-20) engaphandle: Ungalokothi ushiye amakhandlela avuthayo engagadiwe, futhi ungalokothi usebenzise igesi, udizili, noma i-propane generator ephathekayo ngaphakathi kwendlu, indawo engaphansi, igaraji, i-carport, noma uvulandi omboziwe, ngisho nomnyango wegalaji uvuleke kakhulu. Misa amajeneretha aphathekayo ngaphandle ngaphandle okungenani okungu-*** kwamamitha angu-20 (amafidi angu-20)** kusukela kuwo wonke amafasitela, iminyango, nezintuba zokuphuma umoya lapho umsi ukhombe kude nesakhiwo.

I-Carbon monoxide evela kumajeneretha nama-grill ibulala buthule phakathi nemizuzu

Ijeneretha eyodwa kaphethiloli ephathekayo engu-5,000-watt ikhiqiza umsi obulalayo, ongenaphunga njengezimoto zesimanje ezingamakhulu ezigijima ngesikhathi esisodwa. Ukusebenzisa ijeneretha ngaphakathi kwegalaji elinamathiselwe elinomnyango omkhulu wegalaji ovuleke kakhulu kusabangela amazinga abulalayo e-CO ukuthi angene ezindongeni nasezicabheni emakamelweni okulala phakathi nemizuzu eyi-15. Ngokufanayo, ungalokothi ulethe amalahle okushisa, izitofu zekamu, noma izifudumezi ze-propane patio endlini ukuze ufudumale noma upheke, futhi ungalokothi usebenzise uhhavini wekhishi wegesi ukushisa indlu yakho.

Ukugeleza kwesinqumo esihlakaniphile sokunqanyulwa kukagesi ekhaya

flowchart TD
    Start["Kutholwe Ukucisha Kwegridi Kagesi"] --> Scope{"Ingabe imizi engomakhelwane inawo amandla?"}

    Scope -->|Yes: Only Your Home| Breaker["Hlola Iphaneli Yesevisi Eyinhloko ye-Tripped Breaker<br/>Uma intambo yokuwisa yangaphandle iphansi, hlala u-10 m (33 ft) ubuye futhi ushayele isisetshenziswa"]
    Scope -->|No: Neighborhood Blackout| MedCheck{"Ingabe ukhona osebenzisa i-electric life-support noma umoya-mpilo?"}

    MedCheck -->|Yes| MedAction["Shintsha Isixhumi Somoya-mpilo sibe Isilinda Segesi Ecindezelwe<br/>Qinisekisa I-Ventilator / CPAP / LVAD Isipele Sebhethri <br/>Phumela esibhedlela noma endaweni yokukhosela enamandla ngaphambi kokuba ibhethri lehle libe ngaphansi kwamahora angu-2"]
    MedCheck -->|No| Surge["Ukuzivikela Komjikelezo Nokwanda:<br/>1. Bika ukunqamuka kuhlelo lokusebenza lwensiza kagesi/inombolo yocingo<br/>2. Khipha ama-TV, amakhompyutha, nezinto zikagesi ezizwelayo<br/>3. Shintsha i-HVAC nama-heater heater AVALIWE<br/>4. Shiya isibani ESINYE somlindi IVULIWE"]

    MedAction --> Surge
    Surge --> ColdChain["Ukugcinwa Kokudla Namanzi:<br/>• Isiqandisi Sotywina (esiphephile amahora angu-4) Nefriji (iphephile amahora angu-24-48)<br/>• Gcwalisa obhavu namabhodwe uma kumanzi kamasipala ngaphambi kokuba umfutho wehle"]

    ColdChain --> GenCheck{"Ingabe usebenzisa i-generator ephathekayo yamafutha?"}
    GenCheck -->|Yes| GenSafe["UKUBEKA NGAPHANDLE OKUQINILE:<br/>• Beka ngaphandle >= amamitha angu-6 (amafidi angu-20) ukusuka kuwo wonke amafasitela/iminyango<br/>• UNGALOKOTHI ugijime egaraji, kuvulandi, noma eshedeni<br/>• UNGALOKOTHI uxhume okukhipha odongeni (i-backfeeding ibulala abasebenza ngomugqa)<br/>• Hlola ama-alamu e-CO asebenza ngebhethri kuzo zonke izitezi"]
    GenCheck -->|No| Thermal["Lawula Izinga Lokushisa Langaphakathi:<br/>• Ubusika: Hlanganani egumbini eli-1 elibheke eningizimu, beka itende lasendlini, izingubo zogqinsi<br/>• Ihlobo: Iya egumbini elingaphansi/eliphansi, amawindi anomthunzi, amanzi"]

Izintambo zikagesi ezehlisiwe nokuvikelwa kokukhuphuka kukagesi

Umoya onamandla, ukunqwabelana kweqhwa, amalunga esihlahla awile, nokushayisana kwezimoto kuvame ukuletha izintambo zikagesi ezihamba phezulu zinqamule amayadi, imigwaqo, kanye nemigwaqo phakathi nokucima kukagesi.

1. Umthetho wokukhishwa wamamitha angu-10 (33-foot) namandla wesinyathelo

  • Cabanga ukuthi zonke izintambo eziwile zinamandla futhi ziyabulala: Izintambo zokusabalalisa zamandla kagesi aphezulu ezithwala 7,200 kuya ku-34,500 volts zivame ukuhlala zithule futhi zinganyakazi phansi ngaphandle kokucwayiza, futhi izivala zesiteshi esingaphansi ezizenzakalelayo zingathumela amandla kagesi aphezulu abuyele emugqeni ngaphandle kwesixwayiso.
  • Gcina umjikelezo wamamitha angu-10 (33-foot): Hlala okungenani amamitha angu-10 (33 amafidi) kude nanoma iyiphi intambo ewile futhi noma yini ucingo oluyithintayo, okuhlanganisa itiyela elimanzi, amachibi okubhukuda, amatshe eqhwa, amagatsha ezihlahla, izintambo zokuvikela, nezinsimbi zocingo oluxhumanisa amaketango (intambo ephilayo ingafaka uthango oluyikhulu lamamitha othango).
  • Indlela yokuphunyuka kokuthi "Isinyathelo Esingenzeka" (I-Ground Gradient Voltage): Uma intambo ephilayo enamandla amakhulu ithinta umhlaba, amandla asakazayo aphumela ngaphandle enhlabathini ngamaringi kagesi amaphakathi. Ukuhamba ngokuvamile kudala umehluko we-voltage phakathi konyawo lwakho lwangaphambili nonyawo lwangemuva (isinyathelo esinamandla), kuthumela amandla abulalayo phezulu komlenze owodwa futhi phansi komunye. Uma ungaphakathi kwendawo eyingozi eduze kocingo oluwile, UNGAhambi noma ugijime: cindezela izinyawo zakho uqinise ndawonye bese ushova uhlehle (uslayida amathe akho emhlabathini ngaphandle kokuhlukanisa izinyawo zakho) noma gxuma ngonyawo olulodwa uze ucace okungenani ngamamitha angu-15 (amafidi angu-50).

2. Ukuvikela izinto zikagesi zasendlini kokuthi "Inrush Current" kanye nokwanda kokubuyisela

Uma abasebenzi bezinsiza bebuyisela amandla endaweni yangakini, kwenzeka izingozi ezimbili zikagesi:

  1. Ukulandwa Komthwalo Obandayo (I-Inrush Yamanje): Yonke i-compressor yemoto kagesi (iziqandisi, iziqandisi, ama-air conditioner, amaphampu okushisa, amaphampu omthombo) kanye nezinto zokufudumeza zizama ukuqala nge-millisecond efanayo ncamashi ezinkulungwaneni zezindlu. Iziminyanisi zidweba eziphindwe ka-5 kuye kweziyi-7 ze-amperage yazo evamile ekuqaleni, okubangela ama-voltage sags (ama-brownout) alandelwa ama-voltage spikes esikhashana alimaza amabhodi esekethe.
  2. Ukuvikela umonakalo: Ngenkathi ugesi uphelile, phendula ama-circuit breaker CIMILE uthole iphampu yakho emaphakathi ye-AC/yokushisa, isifudumezi samanzi sikagesi, ibanga likagesi, nokomisa izingubo, futhi ukhiphe ugesi ozwelayo. Uma isibani sakho sokukhanya esisodwa sesibuyile futhi sikhanya kancane imizuzu eyi-10 kuye kweyi-15, khanyisa ama-circuit breaker akho amakhulu okukodwa ngesikhathi, ulinde imizuzu engu-2 phakathi kwento ngayinye enkulu esetshenziswayo.

Ukuphepha kwejeneretha ephathekayo: ukuvimbela ubuthi be-CO kanye nokuncelisa emuva

Amajeneretha aphathekayo kaphethiloli, i-propane, kanye ne-diesel awusizo phakathi nokucima kukagesi kwezinsuku eziningi, kodwa ukubekwa okungafanele kanye nezintambo kuzenza kube imbangela ehamba phambili yokufa kwabantu ngemva kwesiphepho.

Ingozi ye-Generator I-Safe, I-Code-Compliant Practice Iphutha Elibulalayo Okufanele Uligweme Kungani Iphutha Libulala
Indawo Yejeneretha (I-Carbon Monoxide) Beka eduze nje ngaphandle emoyeni ovulekile okungenani amamitha angu-6 (amafidi angu-20) kude nayo yonke iminyango, amafasitela, izindawo zokungenisa umoya, namagaraji, lapho kuphuma khona umoya okhombe kude nezakhiwo. Ukuqhuba ijeneretha ngaphakathi kwegumbi elingaphansi, ishedi, uvulandi omboziwe, noma ngaphakathi kwegalaji elinamathiselwe noma elivalekile nomnyango wegalaji ovuliwe. I-generator exhaust iqukethe i-Carbon Monoxide ebulalayo (50,000+ ppm). Ama-wind eddies avunguza isisi esiphuma egalaji elivuliwe noma kuvulandi ngezintuba nemifantu yeminyango, abulale abangaphakathi ngaphansi kwemizuzu engama-30.
Izintambo eziya endlini (Ukuphekelwa kukagesi) Xhuma izinto zikagesi ngokuqondile ezitolo zejeneretha usebenzisa izintambo zokunweba zangaphandle ezisindayo (12 AWG noma 10 AWG), NOMA xhuma nge-*I-Manual Transfer Switch eqinisekisiwe noma Ikhithi yokukhiya yephaneli. Kusetshenziswa amadoda amabili "intambo yokuzibulala" ukuze uxhume ijeneretha endaweni yokukhipha udonga noma isokhethi yokomisa ngaphandle kokuhlukanisa isinqamuli esiyinhloko. I-Backfeeding ithumela u-240V isuka kujeneretha yakho ihlehle ngemitha yakho iye ku-transformer yomgwaqo, inyusa ugesi ifike ku-7,200V noma ku-14,400V* ezintanjeni eziwisiwe zasemgwaqweni kanye nezisebenzi zolayini zokucupha ugesi.
Ukufaka Uphethiloli Nokuphepha Komlilo Vala ijeneretha VALA bese uvumela injini nesifihli ukuthi kuphole okungenani imizuzu engu-15 ngaphambi kokuthela uphethiloli ethini lokuphepha eligunyaziwe. Ukuthela uphethiloli ethangini likaphethiloli ngenkathi ijeneretha isebenza noma ngenkathi i-exhaust manifold ishisa. Uphethiloli ochithiwe ochaphazela kumshini wokukhipha umoya oshisayo uyahwamuka bese uvutha ube yibhola lomlilo ngokushesha.
Ukusebenza kwesimo sezulu esimanzi Isebenza ngaphansi kwe- canopy yejeneretha eyakhelwe inhloso, emaceleni evulekile** endaweni enezinga elomile, futhi ungalokothi uthinte amaswishi ngezandla ezimanzi. Ukusebenzisa ijeneretha engavikelekile emathafeni emvula amile, noma ukuyihambisa ngaphansi kophahla lukavulandi ukuze ihlale yomile. Amanzi asezindaweni zokudayisa adala izingozi zogesi, kuyilapho ukudonsa ijeneretha kuvulandi kubangela ukunqwabelana kwe-CO ebulalayo endlini.

Ukulinganisa kwentambo yesandiso ukuze kuxhunywe into eqondile

Uma ungenayo i-wired transfer switch, sebenzisa i-heavy duty, i-3-prong isekelwe, ilinganiselwe ngaphandle (SJTW or STW) izintambo zokunweba ezintweni zakho zikagesi (ukuvala noma yisiphi igebe sewindi ngegwebu noma ithawula, nokugcina ijeneretha okungenani iqhele ngamamitha angu-6 / amafithi angu-20 ohlangothini ** oluphambene** lwendlu):

  • Ungalokothi usebenzise igeji yangaphakathi engu-16 (16 AWG) lamp cords for refrigerators or space heaters; voltage drop over a thin cord overheats compressor motors and melts cord insulation.
  • Up to 15 meters (50 feet): Use at least a 12-gauge (12 AWG) heavy-duty outdoor cord.
  • 15 to 30 meters (50 to 100 feet): Use a 10-gauge (10 AWG) extra-heavy-duty cord.
  • Safer indoor alternative: Portable Lithium Iron Phosphate (\(\text{LiFePO}_4\)) battery power stations ("solar generators") produce zero emissions and zero carbon monoxide. They can be operated safely inside an apartment or bedroom to power CPAP machines, medical devices, refrigerators, and phones.

Food safety and the 4-hour / 48-hour cold-chain countdown

When the power goes out, bacterial pathogens such as Salmonella, Escherichia coli, Staphylococcus aureus, Listeria monocytogenes, and Bacillus cereus multiply rapidly once perishable food enters the Temperature Danger Zone between 4 degrees Celsius and 60 degrees Celsius (40 degrees Fahrenheit and 140 degrees Fahrenheit).

Step-by-step cold-chain preservation strategy

  1. The 4-Hour Refrigerator Rule: An unopened refrigerator maintains food at or below 4 degrees Celsius (40 degrees Fahrenheit) for approximately 4 hours. Every time you open the refrigerator door to browse for snacks, dense cold air pours out onto the kitchen floor and is replaced by warm room air, cutting safe holding time by 30 to 45 minutes per opening.
  2. The 24-to-48-Hour Freezer Rule: A half-full freezer keeps food safely frozen for about 24 hours if kept closed; a tightly packed, full chest or upright freezer keeps food frozen for 48 hours. If your freezer is only half full when a storm approaches, group all frozen packages tightly together (so they insulate each other like an igloo) and fill empty spaces with jugs of water or bags of ice.
  3. Extending cold holding past 4 hours with ice or dry ice:
    • If the outage will last longer than 4 hours, pack your most perishable refrigerator items (milk, raw meat, poultry, fish, leftovers) into an insulated camping cooler buried in block ice, cubed ice, or frozen gel packs, OR transfer bags of ice from the store into the shelves of your refrigerator to keep the internal cabinet temperature at or below 4 degrees Celsius (40 degrees Fahrenheit).
    • Dry Ice (solid carbon dioxide at -78.5°C / -109.3°F): Eleven kilograms (25 pounds) of dry ice will keep a 280-liter (10-cubic-foot) full freezer safely below freezing for 3 to 4 days. Handle dry ice only with thick leather gloves (never bare skin), wrap it in brown paper or cardboard so it does not touch plastic freezer liners directly, and make sure the kitchen has some ventilation as the \(\text{CO}_2\) sublimates.

USDA & FDA post-outage food triage matrix (Keep vs Discard)

Once power is restored (or when inspecting your refrigerator after more than 4 hours without power), use an appliance thermometer or digital food probe thermometer to check the temperature inside the refrigerator and freezer. Never taste food to determine if it is safe: you cannot see, smell, or taste the heat-stable enterotoxins produced by Staphylococcus aureus or Bacillus cereus, and reheating spoiled meat will not destroy those toxins.

Food Item Category Refrigerated Condition: Exposed Above 4°C (40°F) for More Than 2 Hours (Typically >4 Hours of Outage) Frozen Condition: Freezer Compartment After Power Returns
Raw or Cooked Meat, Poultry, Fish, and Seafood DISCARD. Throw out all raw ground beef, steaks, chicken, pork, fish, shellfish, hot dogs, bacon, and opened lunch deli meats. (Exception: whole, uncut raw country-cured hams or hard dry salami are safe). SAFE TO REFREEZE OR COOK only if the package still contains ice crystals in the center or registers at or below 4°C (40°F) on a food thermometer. If completely thawed and warm above 4°C for >2 hours, discard.
Milk, Cream, Soft Cheeses, and Yogurt DISCARD all liquid milk, buttermilk, cream, sour cream, cottage cheese, ricotta, cream cheese, Brie, Camembert, shredded cheese, and opened baby formula. Safe to refreeze or use if ice crystals remain or temperature is \(\le 4^\circ\text{C}\) (\(40^\circ\text{F}\)).
Hard Block Cheeses, Butter, and Margarine SAFE TO KEEP. Hard cheeses (Cheddar, Swiss, Parmesan, Provolone, Romano in solid blocks), grated Parmesan, and salted butter or margarine remain safe above 4°C. Safe to refreeze or keep.
Eggs and Egg Products DISCARD all raw shell eggs, liquid egg substitutes, hard-boiled eggs, quiches, and custards held above 4°C for more than 2 hours. Discard if thawed above 4°C for >2 hours.
Cooked Leftovers, Casseroles, Soups, Pizza, and Cooked Rice/Pasta DISCARD. Cooked grains, rice, beans, pasta, stews, and meat/cheese pizzas rapidly grow Bacillus cereus and Staphylococcus toxins above 4°C. Safe to cook or refreeze only if ice crystals remain or temperature is \(\le 4^\circ\text{C}\) (\(40^\circ\text{F}\)).
Cut Fresh Fruits, Cut Melons, Leafy Greens, and Cooked Vegetables DISCARD pre-washed bagged salads, cut melons, cooked vegetables, and opened vegetable juice held above 4°C for >2 hours. (Whole, uncut fresh fruits and raw vegetables are SAFE TO KEEP). Safe to refreeze or cook if ice crystals remain; discard if warm above 4°C for >6 hours or showing sour odor.
Condiments, Dressings, and Jams SAFE TO KEEP: Ketchup, mustard, vinegar-based salad dressings, relish, taco sauce, barbecue sauce, soy sauce, olives, peanut butter, jelly, and jams.
DISCARD: Opened mayonnaise, tartar sauce, or creamy horseradish if held above 10°C (50°F) for more than 8 hours.
N/A (typically stored in refrigerator).
Breads, Rolls, Cakes, Tortillas, and Fruit Pies SAFE TO KEEP: Bread, rolls, bagels, tortillas, waffles, muffins, and fruit pies.
DISCARD: Cream-filled pastries, éclairs, cheesecake, or custard pies held above 4°C for >2 hours.
Safe to refreeze all breads and baked goods (except cream/custard fillings thawed above 4°C for >2 hours).

Rule of thumb from the USDA and FDA: "When in doubt, throw it out." A $100 bag of groceries is never worth an emergency hospital admission for severe dehydration or kidney injury from food poisoning during a disaster.

Critical medical devices and temperature-sensitive medications

For millions of households, electricity is a direct medical life-support utility. Prepare and execute these protocols whenever power fails:

1. Electrically powered medical equipment

  • Home mechanical ventilators, LVADs, and parenteral pumps:
    • Check the internal battery runtime display immediately and silence non-critical AC-disconnect audible alarms once acknowledged so you can conserve focus.
    • Plug the unit into its external backup battery pack or a dedicated pure-sine-wave \(\text{LiFePO}_4\) power station.
    • The 2-Hour Evacuation Trigger: Do not wait until your last battery is beeping at 5 percent to seek help. If grid restoration is not guaranteed and your total remaining battery reserve drops to 2 to 3 hours, call your local emergency number (911 / 112 / 999) or travel immediately to a hospital, fire station, or designated municipal medical shelter with backup generator power.
  • Home oxygen concentrators:
    • Stationary home oxygen concentrators draw 300 to 600 watts continuously and stop producing concentrated oxygen the instant grid power fails.
    • Immediately switch the patient's nasal cannula tubing over to their backup compressed oxygen gas cylinder (E-tank or M-tank) and crack the valve wrench open to the prescribed liters-per-minute (\(\text{L/min}\)) flow rate.
    • How to calculate remaining tank time: For a standard portable green E-cylinder (tank factor \(0.28\)), multiply the pressure gauge reading in PSI (minus a 200 PSI safety reserve) by \(0.28\), then divide by the flow rate in \(\text{L/min}\). For example, a full 2,000 PSI E-tank at \(2\text{ L/min}\) lasts: \((2000 - 200) \times 0.28 / 2 = \mathbf{252\text{ minutes}}\) (about 4.2 hours). Call your durable medical equipment (DME) oxygen supplier immediately to request emergency cylinder delivery.
  • CPAP and BiPAP machines for sleep apnea:
    • A standard CPAP machine draws 30 to 60 watts, but turning on the heated humidifier chamber and heated hose triples power consumption to 90 to 120 watts. During a blackout, detach or switch OFF the heated humidifier and heated tubing in your CPAP menu settings; this allows a small 300-watt-hour portable battery station to run your CPAP fan for 3 to 5 full nights instead of just 1 night.
  • Pre-register with your electric utility's Medical Baseline / Priority Registry:
    • Contact your electric utility company before an emergency to submit a physician-signed Medical Baseline / Critical Care / Priority Services Register (PSR in the UK) form. This places your address on priority restoration lists, gives you advance warning before planned public-safety power shutoffs (PSPS), and protects against disconnection.

2. Keeping insulin and refrigerated biologics safe without power

  • Insulin storage rules (FDA / ADA guidelines):
    • Keep unopened insulin vials and pens inside the closed refrigerator for the first 4 hours.
    • Room temperature survival: If the refrigerator warms up, do not panic. Both opened (in-use) and unopened vials/pens of human and analog insulin remain chemically stable and safe to use at room temperatures between 15 degrees Celsius and 30 degrees Celsius (59 degrees Fahrenheit and 86 degrees Fahrenheit) for up to 28 days. (Once unrefrigerated insulin has been kept at room temperature, mark the date on the box and discard any unused portion after 28 days, even if you put it back in the fridge later).
    • Protect insulin from extreme summer heat (>30°C / 86°F) and freezing (<2°C / 36°F): Insulin proteins break down rapidly if exposed to temperatures above 30 to 37 degrees Celsius (86 to 98.6 degrees Fahrenheit) and are permanently destroyed if frozen. Never lay an insulin vial directly against a frozen ice pack or dry ice; wrap the insulin box inside a folded hand towel before placing it in an insulated cooler with a cool gel pack, or use an evaporative water-activated cooling pouch (such as a FRIO pouch), which keeps insulin at a safe 18 to 26 degrees Celsius (64 to 79 degrees Fahrenheit) for days using only tap water.
  • Refrigerated biologics, GLP-1 injections, and liquid antibiotics:
    • Check the manufacturer package insert for medications like adalimumab (Humira), etanercept (Enbrel), semaglutide, tirzepatide, or reconstituted children's amoxicillin suspension. Many biologics allow a single one-time room-temperature excursion (below 25°C to 30°C / 77°F to 86°F) for 14 to 21 days, while others require strict 2°C to 8°C cold-pack storage in an insulated cooler monitored with a min/max digital thermometer.

Surviving extreme winter cold or summer heat during a blackout

When a blackout disables your furnace in a winter blizzard or shuts off air conditioning during a summer heat dome, your home's indoor temperature begins equalizing with outdoor temperatures within 6 to 12 hours.

1. Winter blackout survival: creating a Thermal Micro-Zone and preventing frozen pipes

Even a modern gas furnace or oil boiler cannot run during a power outage because its electronic ignition control board, blower fan, or circulator pump requires AC electricity.

  • Build a single-room "Micro-Zone" (Room-Within-a-Room):
    1. Pick one small interior room (ideally south-facing on the main floor) where all family members and pets will gather and sleep.
    2. Close the doors to all other rooms. Hang thick blankets or sleeping bags over the windows and doorways of your chosen room, and place rolled bath towels along the bottom cracks of exterior doors.
    3. Pitch a camping tent indoors on the living room floor or mattress: Setting up a small nylon dome tent (or draping blankets over a dining table) on top of insulated sleeping pads traps metabolic body heat inside a small air volume, keeping the tent 8 to 14 degrees Celsius (15 to 25 degrees Fahrenheit) warmer than the surrounding unheated house.
  • Layer clothing using the 3-layer system: Wear a moisture-wicking synthetic or wool base layer next to your skin (avoid cotton), a fleece or wool mid-layer, and a windproof outer jacket, plus a warm hat, thick socks, and mittens.
  • Safe vs unsafe indoor heating:
    • SAFE: A wood-burning fireplace or stove with a clean chimney flue; a vented natural-gas fireplace with a standing millivolt pilot; or indoor-certified catalytic propane heaters (UL / CSA indoor-safe with an automatic Oxygen Depletion Sensor [ODS] and tip-over shutoff) used only with a window cracked 2.5 centimeters (1 inch) and a working battery CO alarm.
    • LETHAL (NEVER USE INDOORS): Never use a gas kitchen stove or open gas oven for heat; never bring a charcoal grill, camp stove, kerosene torpedo heater, or outdoor patio heater inside.
  • Preventing domestic water pipes from freezing and bursting:
    • If indoor temperatures drop toward 4 degrees Celsius (40 degrees Fahrenheit): open kitchen and bathroom sink cabinet doors and turn on both hot and cold faucets at the highest and farthest fixture to a slow, continuous drip.
    • If the house will drop below freezing (0°C / 32°F) for an extended period: Turn your main interior water shutoff valve completely OFF and open all faucets on every floor to drain standing water out of your plumbing lines so ice expansion cannot split the pipes (see our frozen pipes guide).

2. Summer heat wave blackout survival

  • Stay on the lowest floor: Hot air rises; move to a basement or ground-floor room, which stays 8 to 10 degrees Celsius (15 to 18 degrees Fahrenheit) cooler than upper floors.
  • Block solar heat gain BEFORE sunlight hits the glass: Cover east-, south-, and west-facing windows with closed blinds, white-backed curtains, or cardboard wrapped in aluminum foil during daylight hours, then open windows at night if outdoor air drops cooler than indoor air.
  • Use active skin wetting and conduction cooling: Pair a battery-powered fan with a water spray mister bottle, drape a cool wet washcloth over the back of your neck, wrists, and groin, or sit with your feet in a basin of cool water.
  • Hydrate on a schedule: Drink at least 250 milliliters (1 cup) of cool water every 30 to 45 minutes and travel to a municipal air-conditioned Cooling Center if anyone develops dizziness, headache, muscle cramps, nausea, or confusion (see our extreme heat guide futhi heat illness first aid).

Water supply, sanitation, and locked garage doors during a blackout

1. Private well pumps versus municipal water systems

  • Homes on private electric water wells: Your electric well pump stops when grid power fails, leaving only 4 to 15 liters (1 to 4 gallons) of pressurized water inside your basement bladder tank before faucets run dry. Conserve that water for drinking.
  • Homes on city municipal water: Prolonged regional blackouts can disable municipal booster pumping stations, dropping street main pressure and triggering a Boil Water Advisory. As soon as a major storm or blackout begins, scrub your bathtub clean and fill the bathtub to the rim with cold tap water (storing 150 to 250 liters / 40 to 65 gallons for washing and flushing toilets) and fill clean pitchers for drinking.

2. How to flush a toilet without running water (the bucket gravity flush)

A standard residential toilet is a mechanical gravity siphon that does not need electricity or pipe pressure to flush:

  1. Scoop 6 to 8 liters (1.5 to 2 gallons) of non-potable water (from your filled bathtub, a rain barrel, a pool, or melted snow) into a bucket.
  2. Pour the bucket of water rapidly all at once directly into the lower toilet bowl (not into the upper tank). The sudden surge raises the water level over the internal gooseneck trap, triggering the gravity siphon and flushing waste down the sewer drain.

3. How to manually open an electric garage door when the power is out

  1. Make sure the garage door is in the fully closed (down) position before pulling the release cord (pulling the release while a door with a broken spring is open overhead can cause the heavy door to crash down).
  2. Locate the red emergency release rope and handle hanging from the ceiling trolley carriage and pull it straight down until the spring lever disengages from the chain/belt shuttle.
  3. Lift the garage door smoothly upward by hand until it rests fully open on its overhead tracks.

Create a 360-degree room lantern with a headlamp and a water jug

Instead of using open-flame candles, strap an LED headlamp (facing inward) around a translucent 4-liter (1-gallon) plastic jug filled with water. The water diffuses the focused LED beam into a bright, safe 360-degree lantern that illuminates an entire living room.

Imibuzo ejwayelekile ukubuzwa

How long does food stay safe inside a refrigerator and freezer when the power goes out?

If you keep the doors closed, a refrigerator keeps food safely cold (at or below 4 degrees Celsius / 40 degrees Fahrenheit) for about 4 hours. A full freezer holds safe freezing temperatures for about 48 hours (or 24 hours if half full). Once a refrigerator has been without power for more than 4 hours and internal temperatures stay above 4 degrees Celsius (40 degrees Fahrenheit) for over 2 hours, discard perishable foods such as meat, poultry, fish, milk, soft cheeses, eggs, and cooked leftovers.

Is it safe to run a portable generator inside my garage if I leave the big garage door wide open?

No. Never run a portable generator inside an attached or detached garage, even with the main garage door wide open. Wind currents draw exhaust fumes containing lethal concentrations of odorless carbon monoxide (CO) through drywall seams, attic hatches, and interior doorways into living spaces within minutes. Always place a fuel-burning generator strictly outdoors at least 6 meters (20 feet) away from all windows, doors, and vents, with the exhaust pointing away from the house.

What is "backfeeding" a generator, and why is plugging a generator into a wall outlet illegal and deadly?

Backfeeding happens when someone connects a generator into a household wall outlet or dryer socket using a double-male cord without isolating the house from the street grid via a certified transfer switch. Electricity from your generator flows backward through your meter into the utility pole transformer outside, which steps your 120/240 volts up to 7,200 or 14,400 volts on downed neighborhood power lines, fatally electrocuting utility lineworkers or neighbors.

How do I keep insulin safe during a multi-day power outage?

Keep insulin inside the closed refrigerator for the first 4 hours. If the refrigerator warms up, both unopened and in-use insulin vials and pens remain safe at room temperatures between 15 degrees Celsius and 30 degrees Celsius (59 degrees Fahrenheit and 86 degrees Fahrenheit) for up to 28 days. If your home gets hotter than 30 degrees Celsius (86 degrees Fahrenheit), place the insulin in a water-activated evaporative cooling pouch or inside an insulated cooler wrapped in a thick towel so it never touches ice directly, because freezing destroys insulin.

Can I still flush my toilets if the power is out or the well pump stops working?

Yes. Standard household toilets work by gravity siphon and do not require electricity or water-pipe pressure to flush. Simply pour 6 to 8 liters (1.5 to 2 gallons) of non-potable water (such as water stored in the bathtub, rainwater, pool water, or melted snow) rapidly from a bucket directly into the lower toilet bowl to trigger the siphon and flush the waste down the drain.

Why should I unplug electronics and turn off my air conditioner or heat pump breaker during a blackout?

When utility crews restore electricity after a blackout, voltage often spikes and sags for the first few minutes, which can damage circuit boards in TVs, computers, and appliances. In addition, if thousands of air conditioners, heat pumps, and electric water heaters all draw heavy startup "inrush current" at the same second the grid comes back online, the combined load frequently trips the substation breakers again. Leave one light switch on as a signal, and wait 10 to 15 minutes after it lights up before turning your large appliance breakers back on one by one.

Sources checked

  • I-Federal Emergency Management Agency (FEMA, United States) & Ready.gov: Amandla Anqamula Izenzo Zokuvikela, Ukuqhubeka Kwedivayisi Yezokwelapha, kanye Namazinga Okubekwa Kwejeneretha Ephathwayo.
  • United States Department of Agriculture (USDA) Food Safety and Inspection Service & U.S. Food and Drug Administration (FDA): Keeping Food Safe During an Emergency: Cold-Chain Time/Temperature Thresholds and Refrigerated/Frozen Food Triage Charts.
  • Centers for Disease Control and Prevention (CDC, United States) & Consumer Product Safety Commission (CPSC): Carbon Monoxide Poisoning Prevention in Disasters (20-foot generator Setback Rules) kanye ne-insulin Storage in Emergency.
  • National Fire Protection Association (NFPA, United States): NFPA 70 (National Electrical Code) Transfer Switch Requirements and Candle Fire Safety in Blackouts.
  • Health and Safety Executive (HSE, United Kingdom) & UK Power Networks: Emergency Power Outage Preparedness, Priority Services Register (PSR) for Vulnerable Customers, and Generator Backfeed Prevention.