Sump pump failure during storms and flooding: emergency basement triage

Броевите за итни случаи се разликуваат по земја. Оваа страница користи 911, бројот за Соединетите Американски Држави и Канада. Многу други земји користат 112, 999 или друг број. Најдете го бројот за вашата земја.

A primary sump pump is a residential foundation's primary mechanical defense against rising groundwater tables, hydrostatic concrete pressure, and severe stormwater infiltration. When a sump pump fails during a torrential rainstorm, rapid snowmelt, or flash flood, water entering through the perimeter drain tile (weeping tile) fills the sump basin within minutes and overflows across the basement slab. A single failed pump can allow thousands of liters of contaminated groundwater into a subterranean living space or utility mechanical room in less than an hour, threatening electrical panels, natural gas furnaces, water heaters, and structural framing.

Surviving a sump pump failure without catastrophic property loss or fatal electrocution requires disciplined emergency triage. You must first evaluate the basement for lethal electrical current in standing water, rapidly diagnose whether the failure stems from power loss, a jammed float switch, a burned-out motor winding, or a frozen discharge line, and immediately deploy secondary pumping or siphon systems before water reaches vulnerable mechanical infrastructure.


Направете го ова сега

  1. Stop at the top of the stairs and verify electrical safety before touching water. If standing water on the basement floor has reached the level of floor-mounted outlets, extension cords, power strips, space heaters, or the base of your furnace or water heater, do not step into the water. Water mixed with soil minerals is a lethal electrical conductor. If anyone is unresponsive in the water, do not enter; call your local emergency number (911 in the United States and Canada, 112 across the European Union, 999 in the United Kingdom, or see our global броеви за итни случаи directory) and request an emergency utility disconnect.
  2. Shut off basement electrical circuits if the panel is safely reachable on dry ground. If your main breaker panel is upstairs or in a dry garage, immediately flip the circuit breakers controlling all basement outlets, lighting, and appliances to the OFF position while leaving the dedicated sump pump circuit active only if the outlet is elevated at least 1.2 meters (4 feet) above the floor. If the main breaker panel is in the flooded basement and reaching it requires stepping into water, stay out and call your electric utility to pull the exterior meter.
  3. Test and free a jammed mechanical float switch. Using a dry wooden broom handle or wearing thick insulated rubber boots and dry rubber gloves on dry footing, inspect the sump basin. Debris, small stones, or pump torque twist frequently cause the buoyant float arm or tether ball to wedge against the basin wall. Gently lift the float upward with the wooden handle; if the motor hums and discharges water immediately, reposition the pump centrally in the pit so the float moves freely.
  4. Reset the GFCI receptacle and execute the piggyback plug bypass. Locate the elevated ground-fault circuit interrupter (GFCI) wall outlet powering the pump and press the Reset button firmly until it clicks. If power is confirmed at the outlet but lifting the float does nothing, unplug the two-part piggyback plug assembly from the wall, separate the two plugs, and plug the single-prong pump motor cord directly into the wall outlet to bypass a broken float switch.
  5. Deploy emergency backup drainage immediately. If the primary motor hums without moving water or remains completely dead, activate your 12-volt battery backup system, lower a portable submersible utility pump attached to a 19-millimeter (0.75-inch) garden hose into the pit, or start an outdoor portable generator positioned at least 6 meters (20 feet) away from all windows and doors.
  6. Исклучете ги вентилите за гас на ниско монтирани апарати и подигнете го имотот. Ако водата се крева низ плочата и покрај напорите за задржување, свртете го контролното копче за гас на бојлерот на ИСКЛУЧЕНО и затворете го рачниот жолт вентил за исклучување на гасот пред водата да достигне длабочина од 25 милиметри (1 инч). Свртете го црвениот прекинувач за итни случаи од страната на вашата HVAC печка на ИСКЛУЧЕНО и подигнете ги критичните предмети на бетонски блокови од пепел со висина од најмалку 200 милиметри (8 инчи).

Дрво за одлука за итна дијагноза

Користете ја оваа дијагностичка шема на тек за да ја изолирате основната причина за дефект на пумпата за помалку од три минути и изберете ја вистинската механичка интервенција.

flowchart TD
    Start["Вода што се издига во јамата на шахтата или се прелева на подот во подрумот"] --> WaterDepth{"Дали стоечката вода ги допира електричните кабли, приклучоците или основите на апаратот?"}
    WaterDepth -->|"Да"| Evacuate["НЕ ЧАЗНЕТЕ ВО ВОДА<br/>Исклучете го главниот напојување од сув под или повикајте ја електричната мрежа и службите за итни случаи"]
    WaterDepth -->|"Не, подот е сув или безбеден"| MotorSound{"Дали моторот на пумпата за картер испушта звук?"}

    MotorSound -->|"Тивко"| CheckPower["Притиснете RESET на излезот GFCI и проверете го прекинувачот на главниот панел"]
    CheckPower --> PowerRestored{"Дали ресетирањето ја врати работата на пумпата?"}
    PowerRestored -->|"Да"| Monitor["Монитор за 3 циклуси; проверете дали има прегревање или дефекти на земјата"]
    PowerRestored -->|"Не, сè уште молчи"| LiftFloat["Рачно подигнете ја пливачката рака со сува дрвена рачка"]

    LiftFloat --> FloatResult{"Дали пумпата започнува кога ќе се подигне пловиот?"}
    FloatResult -->|"Да"| FixFloat["Повторно центрирајте ја пумпата во сливот така што пливањето ги расчистува ѕидовите на јамата и цевките"]
    FloatResult -->|"бр"| Piggyback["Исклучете го прекинувачот со пигџибек; приклучете го кабелот на моторот директно во штекер"]

    Piggyback --> BypassResult{"Дали моторот работи на директна моќност?"}
    BypassResult -->|"Да"| ManualRun["Пливачкиот прекинувач е мртов; циклус пумпа рачно со приклучување и исклучување додека прекинувачот не се замени"]
    BypassResult -->|"бр"| DeadMotor["Изгорен примарниот мотор или исклучен напојувањето на мрежата; веднаш распоредете резервна пумпа или генератор"]

    MotorSound -->|"Силно потпевнува или вибрира, вода не се движи"| UnplugMotor["Веднаш исклучете ја пумпата за да спречите изгорување на термичката намотка"]
    UnplugMotor --> InspectImpeller["Проверете го долниот екран за довод за кал, чакал или пластика"]
    InspectImpeller --> CheckDischarge["Проверете ја ориентацијата на обратниот вентил, издупчете ја дупката за плачење од 5 mm (0,19 инчи) и проверете дали надворешната цевка за празнење не е замрзната"]

Фаза 1: Проценка на електрична опасност и исклучување на комуналните услуги

Влегувањето во поплавен подрум е една од водечките причини за електричен удар во станбени простории за време на бури. Подземните води никогаш не се чиста дестилирана вода; носи растворени електролити, ѓубрива за тревникот, патни соли и минерални јони кои спроведуваат смртоносна наизменична струја (AC) струја низ влажна бетонска плоча.

Смртоносна опасност од струен удар во поплавени подруми

Никогаш не влегувајте во стоечката вода во подрумот за да го исклучите апаратот, да ја проверите пумпата за картер или да го превртувате прекинувачот. Потопениот продолжен кабел или компромитирана жица на моторот на апаратот го напојуваат целиот базен со вода. Дури и носењето стандардни работни чизми нема да ве заштити ако водата го надмине работ на багажникот или ако вашата рака допре заземјена метална цевка, бакарна водоводна линија или челична потпорна колона додека стоите на влажен бетон.

Оценување на потенцијалот на чекорот и напојуваната вода

  1. Проверете од слетувањето на горните скали: Запалете фенерче со висок лумен надолу во подрумот пред да се спуштите. Побарајте потопени ленти за напојување со повеќе излези, кабли за одвлажнување, приклучоци за замрзнувач на градите или садови за машината за перење.
  2. Гледајте за визуелни и аудитивни електрични индикатори: Побарајте слабо сино или портокалово искри во близина на ѕидните плинтуси, слушајте јасно зуење од 60 херци или 50 херци што доаѓа од потопените жици и забележете каков било остар мирис на запален озон или топење на ПВЦ изолација.
  3. Проверете дали има чувство на пецкање: Ако допрете метална ограда, канал од печката или бакарна водоводна цевка на скалите и почувствувате дури и најмали вибрации или чувство на пецкање, системот за заземјување на зградата се напојува поради дефект. Повлечете се веднаш и евакуирајте ја зградата.
  4. Изолација на далечински прекинувач: Ако вашиот главен електричен сервисен панел се наоѓа на приземје, во приложена сува гаража или е монтиран на надворешниот ѕид од куќата, застанете на сува гумена подлога или сува дрвена табла и исклучете ги поединечните гранки што ги хранат садовите во подрумот, просторијата за перење и печката. Оставете го прекинувачот на пумпата само ако неговиот сад е високо на ѕидот и целосно сув.

Заштита на системите за греење со природен гас, пропан и нафта

Кога надојдената вода се крева низ подрумот, механичките системи за греење се соочуваат и со ризици од експлозија и со неповратно оштетување на компонентите:

  • Гласни вентили за електронски бојлер: Современите бојлери со природен гас и течен пропан користат електронски вентил за контрола на гас и сензор за запалива пареа поставен на 50 до 75 милиметри (2 до 3 инчи) над подната тава. Ако водата од поплава го потопи сензорот за запалива пареа или електронскиот модул, безбедносното заклучување трајно се прекинува, што бара целосно замена на вентилот и сензорот пред уредот повторно да се запали.
  • Ризици од пловноста на термоспојот и резервоарот: Ако водата се крене доволно високо за да изгасне стоечка пилотска сијалица додека неисправниот механички вентил за гас останува делумно заглавен, неизгорениот гас може да истече во затворениот подрум. Ако водата достигне длабочина од 300 до 450 милиметри (12 до 18 инчи), делумно празен резервоар за бојлер или резервоар за масло за греење може да стане пловни, да лебди нагоре и да пукне крути црни железни цевки за гас или бакарни линии за снабдување со масло.
  • Веднаш затворање на вентилот: кога водата се приближува за 25 милиметри (1 инч) од основата на вашиот бојлер или печка, завртете го контролниот бројчаник за гас на ИСКЛУЧЕНО и свртете го рачниот топчест вентил за гас со четврт вртење на вертикалната цевка за снабдување за 90 степени, така што рачката седи нормално на цевката.

Фаза 2: Сеопфатна механичка и електрична дијагностика

Откако ќе потврдите дека областа околу јамата на картерот е безбедно да се приближи, систематското отстранување на проблеми открива дали постоечката примарна пумпа може да се оживее за неколку минути.

Забележан симптом Веројатна основна причина Дијагностичка верификација Итна поправка на теренот за итни случаи
** Јама прелива; моторот целосно тивко; куќата има моќ** Исклучен GFCI штекер, исклучен главниот прекинувач или заглавен пливачки прекинувач Тест штекер со светилка или полнач за телефон; подигнете ја пливачката рака рачно со дрвен стап Притиснете го копчето GFCI Ресетирање; повторно центрирајте ја пумпата подалеку од ѕидовите на јамата; бајпас прекинувач со пигџибек
** Моторот гласно брмчи 5 до 10 секунди, а потоа постојано се исклучува ** Заглавени сечила на работното коло или запленети моторни лежишта што предизвикуваат внатрешно термичко преоптоварување Исклучете ја пумпата; извадете го од јамата или допрете во доводната основа за да почувствувате чакал или остатоци Извадете ги заглавените камења, пластика или корени од волутот на работното коло со клешти со игла
Пумпата работи постојано со нормална брзина; нивото на водата никогаш не паѓа Воздушна брава во куќиштето на работното коло, скршена осовина на работното коло или замрзната надворешна линија за празнење Проверете дали има проток на вода на надворешната излезна цевка; проверете ја цевката под обратниот вентил за дупка за плачење Дупчете дупка за плачење од 5 mm (0,19 инчи) помеѓу пумпата и обратниот вентил; исклучете ја замрзнатата надворешна линија
Пумпата нормално ја празни јамата, се исклучува и водата веднаш се враќа внатре Проверете го вентилот инсталиран наопаку или внатрешен гумен капак е скинат од остатоци Слушајте како гласна брза вода паѓа по вертикалната ПВЦ цевка кога моторот запира Одвртете ги прицврстувачите на нерѓосувачките црева на обратниот вентил; отстранете ги заглавените камчиња или инсталирајте резервен вентил
Пумпата се вклучува и исклучува на секои 3 до 5 секунди (кратко возење велосипед) Поставете го вертикалното стоп за пливање премногу тесно, или дијаметарот на сливот е премал за волумен на доток Гледајте го растојанието на патување на вертикалната пливачка прачка помеѓу активирањето и исклучувањето Приспособете ја пливачката запчаница повисоко на вертикалната шипка за да го зголемите волуменот на циклусот на пумпата
Излезот GFCI го исклучува моментот кога моторот на пумпата е приклучен Навлегување на вода во внатрешноста на куќиштето на моторот предизвикува електричен краток спој од топла до земја Приклучете ја пумпата во различно коло GFCI; ако веднаш се сопне, намотките се скратуваат Веднаш напуштете ја примарната пумпа; не приклучувајте на штекер што не е GFCI; распореди резервна пумпа

Решавање проблеми со пливачки прекинувачи и бајпас на пиггибек приклучокот

Речиси 70 проценти од дефектите на пумпата се предизвикани од дотраен или попречен пливачки прекинувач, а не од дефект на електричен мотор. Пумпите за цевковод користат три дизајни на главни прекинувачи:

  • Заврзани пливачки прекинувачи (топче на флексибилен кабел): Потребен е широк корито со дијаметар од најмалку 450 милиметри (18 инчи). Ако вртежниот момент на стартување ја помести пумпата, врзаната топка се фаќа за брановидниот ѕид или куките под влезната цевка од 100 милиметри (4 инчи) за плачење. Завртете го телото на пумпата за 30 до 45 степени во внатрешноста на јамата, така што врзувачот се лула во отворена вода и врзете ги вишокот кабли за напојување надвор од неговата патека.
  • Вертикални механички пливачки прекинувачи (лизгачки на водилка): Железната окерна бактерија (лигите од портокал) или калциумовата вага може да ја обложат водичката шипка и да го врзат пливачкиот цилиндер. Избришете ја вертикалната водилка со партал и рачно работете ја шипката нагоре и надолу неколку пати.
  • Електронски прекинувачи за притисок во цврста состојба и дијафрагма: строго исчистете ги електронските метални сонди со сензор со бел оцет и цврста четка за да го отстраните изолациониот слој за детергент или лигите од железо.

Ако контактите на пливачкиот прекинувач не успеале внатре, можете да го заобиколите прекинувачот за 10 секунди ако вашата пумпа користи дводелен приклучок на ѕидниот сад:

  1. Со суви раце, исклучете го склопот на пигџибек од ѕидниот штекер GFCI.
  2. Pull the rear plug (the pump motor cord) out of the back of the front pass-through plug (the float switch cord).
  3. Приклучете го приклучокот на моторот на пумпата директно во ѕидниот сад. Ако пумпата веднаш ја исцеди јамата, вашиот мотор е целосно здрав. Оставете го скршениот пливачки прекинувач исклучен и вртете ја пумпата рачно на секои 10 до 20 минути со приклучување и исклучување на кабелот на моторот додека не помине бурата.

Never run a submersible sump pump dry

When operating a pump manually via a bypassed piggyback plug, never walk away and leave the pump running after the pit empties. Submersible sump pumps rely on surrounding water for cooling and use water-lubricated shaft seals. Running a pump dry for more than 2 to 3 minutes will melt the mechanical shaft seal, overheat the motor windings, and destroy the pump permanently.

Clearing jammed impellers and intake screens

If the pump motor hums loudly when energized, vibrates the PVC pipe, and clicks off after 5 to 15 seconds via its internal thermal overload switch, the impeller is jammed by debris:

  1. Disconnect power completely: Unplug the pump power cord from the wall outlet. Never put your hands into a sump basin while the pump is plugged in; once the thermal overload cools, the motor will restart without warning and can cause severe hand injuries.
  2. Loosen the check valve union and lift the pump: Use an 8-millimeter (5/16-inch) nut driver or flathead screwdriver to loosen the stainless steel hose clamp on the flexible check valve coupler above the pit cover, and lift the pump out by its top handle onto a plastic bag.
  3. Clear the obstruction: Flip the pump onto its side, shine a flashlight into the bottom intake opening, and use needle-nose pliers or a flathead screwdriver to pry out stones, concrete chips, or plastic debris wedged between the impeller vanes and the volute housing. Spin the impeller blade manually with the tip of the screwdriver to verify smooth 360-degree rotation.

Phase 3: Resolving discharge pipe blockages, check valves, and air locks

If the pump motor spins freely and sounds normal, yet the water level in the sump basin refuses to drop, the hydraulic path between the impeller and the exterior yard is obstructed:

  • Eliminating an impeller air lock: When a sump pit drains completely dry, a pocket of air can remain trapped inside the lower impeller chamber while the weight of the water column sitting above the check valve holds the check valve shut. Inspect the vertical PVC discharge pipe inside the sump pit between the pump's threaded discharge outlet and the bottom of the check valve for a 5-millimeter (0.19-inch) anti-airlock weep hole. If mineral scale or iron slime has plugged it, poke a stiff wire or nail through the hole. If no hole exists, unplug the pump and drill a single 5-millimeter (3/16-inch) hole through one wall of the PVC pipe roughly 100 millimeters (4 inches) above the top of the pump housing and below the check valve, angled downward at 45 degrees so the thin relief stream shoots downward into the pit.
  • Troubleshooting check valve failures: Every check valve has a raised arrow on its body indicating Direction of Flow, which must point upward away from the pump. If installed backward, zero water can exit. If a check valve flapper is jammed shut during a midnight storm and you lack a spare valve, loosen both hose clamps, remove the check valve body, cut out the internal rubber flapper with a utility knife so the body acts as a hollow tube, and clamp it back onto the pipe.
  • Clearing frozen exterior discharge pipes: During winter rain-on-snow events or early spring thaws, poorly sloped exterior PVC discharge pipes or buried lawn popup emitters can freeze solid with ice. If the interior vertical PVC pipe feels rock-hard under pressure while the pump runs and no water exits outside, unplug the pump immediately so it does not overheat. Loosen the upper stainless steel band clamp on the flexible rubber Fernco coupling inside the basement, disconnect the frozen exterior run, clamp a temporary 38-millimeter (1.5-inch) flexible discharge hose onto the vertical pipe stub, and route it out a slightly opened basement window at least 3 to 5 meters (10 to 16 feet) downslope from the foundation.

Phase 4: Emergency backup pumping and power alternatives

When a storm knocks out the municipal electrical grid or your primary pump motor suffers an unrecoverable winding failure, you must immediately establish secondary water extraction. During peak storm saturation, a basement perimeter drain can feed 40 to 110 liters per minute (10 to 30 gallons per minute) into the sump pit.

Backup System Type Flow Capacity at 3 m (10 ft) Head Power Source Required Continuous Runtime Key Advantages and Limitations
12V DC Battery Backup Pump 75 to 130 L/min (20 to 35 GPM) 12V Deep-Cycle AGM or Marine Battery (75 to 120 Ah) 5 to 8 hours continuous; 24 to 48 hours intermittent Automatic activation via elevated second float; battery eventually depletes in multi-day blackouts
Portable Submersible Utility Pump 60 to 115 L/min (15 to 30 GPM) 120V/230V AC Outlet or Portable Generator Unlimited while AC power or fuel is available Капува директно во јама на градинарско црево; стандардното градинарско црево го ограничува протокот за 30 до 40 проценти
Резервна копија напојувана со вода (Вентури) 45 до 75 L/min (12 до 20 GPM) Општински градски притисок на вода од 2,8 до 5,5 бари (40 до 80 psi) Неограничено; бара нула електрична енергија или батерии Работи на неодредено време при повеќедневни прекини на струја; не може да се користи на приватни системи за вода од бунари
Пренослив инвертер/генератор на гас Напојува примарна AC пумпа од ⅓ или ½ HP со 150+ L/min (40+ GPM) Бензин, пропан или природен гас 8 до 14 часа по резервоар гориво Одржува да работи примарната пумпа за наизменична струја со целосен капацитет; се применуваат строги правила за поставување на јаглерод моноксид на отворено
** 12V автомобилски инвертер за напојување ** Напојува пумпа до ⅓ КС (потребна е континуирана 1.500 W / 3.000 W напојување) Работен автомобил или камион алтернатор и 12V батерија Неограничено додека моторот на возилото работи во мирување со гориво Користи семејно возило како генератор за итни случаи; бара тежок инвертер од чист синусен бран прицврстен на батеријата
**Рачна кофа за спасување / сифон ** 15 до 30 л/мин. (4 до 8 GPM) Човечка физичка работа или степен на гравитација во надолнина Ограничена од човечката физичка исцрпеност Одбрана во последно средство; Сифонирањето работи само ако надворешното земјиште се спушта надолу под нивото на подрумот

1. Безбедно ракување со пренослив генератор за време на бура

Ако затемнувањето ја оневозможи вашата примарна пумпа и поседувате пренослив бензин или генератор со двојно гориво, неговото брзо активирање може да ја задржи вашата примарна пумпа за наизменична струја да работи со полн капацитет.

Труење со јаглерод моноксид (CO) од генераторите

Никогаш не ракувајте со пренослив генератор во подрум, прикачена гаража, простор за лази, затворен трем или во близина на отворен прозорец. Издувните гасови на генераторот содржат смртоносни нивоа на јаглерод моноксид без мирис и боја, кој може да ги онеспособи и убие патниците за помалку од 15 минути. Секогаш поставувајте го генераторот на отворено најмалку 6 метри (20 стапки) подалеку од зградата со пригушувачот за издувни гасови насочен подалеку од сите прозорци, врати и доводи за климатизација на воздухот. За целосни инструкции за поставување, консултирајте се со нашите Водич за безбедност на генераторот и јаглерод моноксид.

  • Големинација на продолжниот кабел за палење на индукцискиот мотор: пумпа со ⅓ коњски сили или ½ коњски сили привлекува приближно 5 до 8 ампери додека работи (600 до 960 вати), но бара краток индуктивен стартен пренапон (заклучен ротор засилувачи) од 25,000 до 15 ампери вати) за првата половина секунда кога моторот се врти. Никогаш не користете тенок кабел за внатрешна светилка со 16 метри, што предизвикува пад на напонот и го прегрева моторот. Секогаш вклучете еден тежок, надворешен оценет 12-мерач (3,3 mm²) или 10-мерач (5,2 mm²) заземјен продолжен кабел со три огради директно од 20-амперскиот GFCI приклучок на генераторот до приклучокот на пумпата за картер.

2. Автомобилски батерии, преносни пумпи за комунални услуги и симнување

  • Напојување од батеријата на автомобилот или камионот: ако вашата резервна батерија од 12 волти еднонасочна струја се испразни за време на продолжено затемнување, можете да ја исклучите и да ги прицврстите позитивните (црвени) и негативните (црни) одводи на резервната пумпа на резервна автомобилска батерија од 12 волти, пренесена од второ возило, давајќи ви ја пумпата од 2 до 4 волти, додека примарното полнење на батеријата е длабоко во циклусот. кабли поврзани со автомобил во празен од. За да ја активирате стандардната пумпа за наизменична струја од 120V/230V од возило во мирување на отворено, прицврстете 1.500-вати континуиран (3.000-вати пренапони) инвертер на чист синусен бран директно до терминалите на батеријата на возилото и вклучете го продолжен кабел со 12 вати до подрумот.
  • Употреба на пренослива услужна пумпа: Спуштете самостојна потопна услужна пумпа во јамата на картерот, навалувајќи ја под агол од 45 степени додека се потопува, така што заробените воздушни меури излегуваат од долната доводна плоча. Користете кратко градинарско црево од 19 милиметри (¾ инчи) или флексибилно црево за празнење од 38 милиметри (1,5 инчи) исфрлено од прозорецот на подрумот наместо тесно градинарско црево од 16 милиметри (⅝ инчи), кое го ограничува протокот за 35 проценти.
  • Гравитационо исфрлање и чување на кофата: ако вашиот надворешен двор се спушта надолу под висината на нивото на водата во подрумот, потопете го градинарското црево од 15 метри целосно во јамата за да остане нула воздух внатре, измерете го доводниот крај во јамата со тула и истргнете го надвор од јамата под јамата; Гравитацијата ќе исфрли 10 до 18 литри во минута (2,5 до 5 галони во минута) без струја. Кога се чува рачно со кофи од 19 литри (5 галони), никогаш не фрлајте ја зачуваната вода во одводот на подрумот, туш или мијалник, кои често се поврзуваат назад во периметарската плочка за плачење и течат директно назад во вашата јама на картерот. Носете кофи горе во тоалетот на првиот кат или исфрлете ги на отворено најмалку 3 до 5 метри (10 до 16 стапки) надолу од темелот.

Фаза 5: Хидростатички притисок, сушење после поплава и одбрана од мувла

Кога подземните води ја заситуваат почвата околу ѕидовите на подрумот и под вашата бетонска подна плоча, таа врши огромна хидраулична сила нагоре и навнатре позната како хидростатски притисок. На секои 300 милиметри (1 стапа) длабочина на стоечка подземна вода наредена на надворешната страна на ѕидот на темелот врши приближно 3 килопаскали (62,4 фунти по квадратен метар) внатрешен страничен притисок.

Не испумпувајте премногу брзо длабоко поплавен подрум за време на максималната заситеност

Ако катастрофален дефект или пробивање на насипот го наполни вашиот подрум со 1 метар (3,3 стапки) или повеќе стоечка вода додека надворешниот двор е сè уште целосно заситен или потопен под надојдена вода, не пумпајте го подрумот да се исуши одеднаш. Тежината на водата во подрумот го балансира огромниот внатрешен притисок на течната кал и подземните води кои притискаат на надворешната страна на ѕидовите. Пумпањето на внатрешноста на суво додека надворешната земја е течна може да предизвика ѕидовите од ѕидарните блокови да се свиткаат навнатре или да предизвика пукање и издигнување на бетонската подна плоча нагоре. Почекајте додека надворешните поплави не се повлечат, а потоа пумпајте го нивото на водата надолу во постепени фази од 300 до 600 милиметри (1 до 2 стапки) дневно. За голема структурна нестабилност, консултирајте се со нашиот водич за структурни оштетувања и колапс.

48-часовен протокол за сушење и дезинфекција

Откако ќе се извади стоечката вода, спорите на мувлата (Aspergillus, Penicillium и Stachybotrys) почнуваат да 'ртат на влажна хартија од гипс картон, дрвени нишки за рамка и тепих во рок од 24 до 48 часа кога релативната влажност надминува 60 проценти.

  1. Вакумирајте ја и исчистете ја плочата: Користете тежок влажен/сув вакуум во продавницата (со отстранет филтер за сув хартија) и гумен гумен гумен за подот за да ги турнете сите барички од ниските точки на бетонскиот под директно во коритото. Доколку дојде до повратен проток на отпадни води, следете ги целосните протоколи за биоопасност во нашата резервен водич за итни случаи за отпадна вода.
  2. **. пресечете го на ленти, вреќајте го и фрлете го. Бидејќи гипсниот ѕид од гипс ја исфрла подземната вода нагоре преку капиларно дејство, отстранете ги плинтусите и отсечете го влажниот гипс ѕид хоризонтално најмалку 300 милиметри (12 инчи) над највисоката ознака за вода, а потоа извлечете ја целата влажна изолација од фиберглас или целулоза зад неа за да можат да дишат дрвените столпчиња.
  3. Дезинфицирајте и одвлажнете агресивно: Избришете го изложениот бетон и дрвените рамки со топла вода за детергент, а потоа нанесете средство за дезинфекција регистрирано во EPA или раствор за белење со хлор за домаќинство, разреден на 240 милилитри (1 чаша) белило без мирис на 3,8 литри ( 1 мил (1 мил. галон) вода. Чувајте ги прозорците во подрумот затворени додека постојано работат одвлажнувачи со голем капацитет и вентилатори на подни вентилатори додека содржината на влага во дрво не падне под 15 проценти, а релативната влажност остане под 50 проценти. Погледнете го нашиот целосен водич за мувла по оштетување на вода.
  4. Надградба за долгорочен технолошки вишок: штом ќе се опорави, надградете на 600-милиметарски (24-инчен) перфориран слив во кој е сместена примарна пумпа од леано железо што се потпира на цврст бетонски блок за поплочување и покачена резервна батерија AGM од 12 волти или општинска резервна пумпа на вода напојувана со вода, и резервна пумпа за аларм со висока/W. фитинг на воздушниот јаз за ослободување од замрзнување.

Најчесто поставувани прашања

Како брзо да тестирам дали моторот на пумпата ми е мртов или дали е скршен само пливачкиот прекинувач?

Проверете го електричниот приклучок на ѕидниот штекер за да видите дали вашата пумпа користи дводелен приклучок (каде што кабелот на пумпата се приклучува во задниот дел од приклучокот за пливачки прекинувач). Со суви раце и стоење на суво тло, исклучете го уредот од ѕидот, одделете ги двата приклучоци и приклучете го приклучокот на моторот со една пумпа директно во ѕидниот приклучок под напон. Ако пумпата веднаш се запали и го испразни сливот, вашиот мотор е целосно во ред и само пливачкиот прекинувач откажа. Можете да ракувате со пумпата рачно со приклучување и исклучување за време на бура додека не го замените пливачкиот прекинувач.

Може ли да ја приклучам мојата пумпа за картер во стандарден продолжен кабел за домаќинство за време на итен случај?

Никогаш не користете тенок продолжен кабел за домаќинство со 16 или 18 месечини за да ја напојувате пумпата за картер. Моторите на пумпата за картер бараат висок индуктивен наплив на струја за стартување (често од 15 до 25 ампери за дел од секундата). Лесниот кабел предизвикува сериозен пад на напонот на приклучоците на моторот, спречувајќи го моторот да достигне целосна брзина на стартување, исклучувајќи го внатрешниот прекинувач за термичко преоптоварување и создавајќи акутен пожар и опасност од струен удар на влажен под. Ако морате да користите продолжен кабел за да стигнете до генератор или до штекер GFCI на катот, користете еден тежок, надворешен оценет 12-мерач или 10-мерач заземјен кабел со три страни, не подолг од 15 метри (50 стапки).

Зошто пумпата ми работи непрекинато без да го намали нивото на водата во јамата?

Кога моторот на пумпата непрекинато се врти со нормален чекор без придвижување на вода, тоа е речиси секогаш предизвикано од едно од четирите проблеми: заклучување на воздухот заглавено во куќиштето на работното коло (предизвикано од недостиг или затнат 5-милиметарски / 0,19-инчен дупка за плачење во ПВЦ цевката под обратниот вентил), затнат долен довод кој бил блокиран од пластичен довод надолу. или има заглавено затворено, или замрзната надворешна цевка за празнење. Исклучете ја пумпата веднаш за да не се прегрее, проверете дали надворешната цевка е чиста и исчистете ја или издупчете ја релјефната дупка од 5 милиметри помеѓу телото на пумпата и обратниот вентил.

Колку долго ќе работи резервната пумпа за батерии од 12 волти за време на прекин на напојувањето со бура?

Целосно наполнета 12-волтна морска батерија со длабок циклус или абсорбента стаклена подлога (AGM) со брзина од 75 до 100 ампер-часови ќе ја напојува резервната пумпа за приближно 5 до 8 часа непрекинато, непрекинато работење. Меѓутоа, бидејќи пумпите на картер вообичаено кружат со прекини (работат од 10 до 20 секунди на секои неколку минути додека се полни јамата), здравата резервна копија на батеријата обично го штити подрумот за 24 до 48 часа наизменично пумпање на бури. Можете да го продолжите времето на работа во повеќедневно затемнување со поврзување на две идентични батерии со длабок циклус заедно паралелно (поврзување позитивно со позитивно и негативно со негативно) или со полнење на исцрпената батерија со помош на кабли за скокачи поврзани со возило што работи на отворено.

Зошто никогаш не треба да ја фрлам водата од јамата со резерва во одводот на подрумот или мијалникот во подрумот?

In the majority of residential homes, basement floor drains connect either directly into the foundation perimeter weeping tile system (which drains right back into the sump pit) or into the municipal storm or sanitary sewer lateral running beneath the basement floor. Dumping buckets of sump water into a basement floor drain creates an endless circular loop where the water flows straight back into your sump basin within seconds, or overwhelms a pressurized sewer lateral and backs up through other basement fixtures. Always carry bailed buckets upstairs to a first-floor toilet or dump them outside at least 3 to 5 meters (10 to 16 feet) downslope from the foundation.

Is it safe to pump out a completely flooded basement immediately while the storm is still raging outside?

If your basement has filled with a minor layer of water (such as 25 to 150 millimeters / 1 to 6 inches), you should pump it out as quickly as possible after verifying electrical safety. However, if a catastrophic flood has filled the basement with 1 meter (3.3 feet) or more of deep water while the ground outside is still completely submerged, pumping the basement empty all at once is structurally dangerous. The internal water weight helps brace the foundation walls against the massive inward hydrostatic pressure of the saturated exterior soil. Wait until outdoor floodwaters recede below ground level, then pump the basement down in increments of 300 to 600 millimeters (1 to 2 feet) per day while inspecting the walls for inward bowing.


Поврзани водичи


Проверени извори

  • Federal Emergency Management Agency (FEMA) (United States) - Homeowner's Guide to Retrofitting and Protecting Building Utilities from Flood Damage (FEMA P-312 and P-348)
  • Centers for Disease Control and Prevention (CDC) (United States) - Electrical Safety and Carbon Monoxide Prevention After a Flood or Natural Disaster
  • Environmental Protection Agency (EPA) (United States) - Brief Guide to Mold, Moisture, and Your Home
  • Health and Safety Executive (HSE) (United Kingdom) - Electrical Safety in Wet and Flooded Domestic Environments
  • Institute of Inspection, Cleaning and Restoration Certification (IICRC) (International) - ANSI/IICRC S500 Standard for Professional Water Damage Restoration
  • Sump and Sewage Pump Manufacturers Association (SSPMA) (United States) - Recommended Guidelines for Residential Sump Pump Installation and Maintenance